• Title/Summary/Keyword: Parallel imaging technique

Search Result 42, Processing Time 0.028 seconds

A Study on the Difference Method of Magnetic Resonance Signal Measurement when Using Multi-channel Coil and Parallel Imaging

  • Choi, Kwan-Woo;Lee, Ho-Beom;Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.220-226
    • /
    • 2017
  • SNR (signal to ratio) is a criterion for providing objective information for evaluating the performance of a magnetic resonance imaging device, and is an important measurement standard for evaluating the quality of MR (Magnetic Resonance) image. The purpose of our study is to evaluate the correct SNR measurement for multi-channel coil and parallel imaging. As a result of research, we found that both T1 and T2 weighted images show the narrowest confidence interval of the method recommended by NEMA (The National Electrical manufacturers Association) 1 having a single measurement method, whereas the ACR (American College of Radiology) measurement method using a multi-channel coil and a parallel imaging technique shows the widest confidence interval. There is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a ACR measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

Usefulness of Parallel Imaging Technique in MRCP for Liver Donor (간 공여자의 자기공명췌담관조영술에서 병렬 영상 기법의 유용성)

  • Lim, woo-taek;Jung, hong-ryang
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.149-150
    • /
    • 2015
  • 병렬영상기법(parallel imaging technique)은 하나의 수신 코일을 사용하는 기존의 방식과 달리 다수의 수신코일을 이용하여 데이터를 획득하는 기법으로서 검사시간 및 공간해상도를 향상시키기 위해 사용된다. 본 논문은 간 공여자의 자기공명영상 췌담관 조영술에서 간담도 영상의 선예도 향상을 위한 병렬영상기법의 유용성을 연구하고자 하였다.

  • PDF

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon;Kim, Sung Mok;Park, Sung-Ji;Kim, Min-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

Design and Implementation of High-Resolution Integral Imaging Display System using Expanded Depth Image

  • Song, Min-Ho;Lim, Byung-Muk;Ryu, Ga-A;Ha, Jong-Sung;Yoo, Kwan-Hee
    • International Journal of Contents
    • /
    • v.14 no.3
    • /
    • pp.1-6
    • /
    • 2018
  • For 3D display applications, auto-stereoscopic display methods that can provide 3D images without glasses have been actively developed. This paper is concerned with developing a display system for elemental images of real space using integral imaging. Unlike the conventional method, which reduces a color image to the level as much as a generated depth image does, we have minimized original color image data loss by generating an enlarged depth image with interpolation methods. Our method was efficiently implemented by applying a GPU parallel processing technique with OpenCL to rapidly generate a large amount of elemental image data. We also obtained experimental results for displaying higher quality integral imaging rather than one generated by previous methods.

Real-time Fluorescence Lifetime Imaging Microscopy Implementation by Analog Mean-Delay Method through Parallel Data Processing

  • Kim, Jayul;Ryu, Jiheun;Gweon, Daegab
    • Applied Microscopy
    • /
    • v.46 no.1
    • /
    • pp.6-13
    • /
    • 2016
  • Fluorescence lifetime imaging microscopy (FLIM) has been considered an effective technique to investigate chemical properties of the specimens, especially of biological samples. Despite of this advantageous trait, researchers in this field have had difficulties applying FLIM to their systems because acquiring an image using FLIM consumes too much time. Although analog mean-delay (AMD) method was introduced to enhance the imaging speed of commonly used FLIM based on time-correlated single photon counting (TCSPC), a real-time image reconstruction using AMD method has not been implemented due to its data processing obstacles. In this paper, we introduce a real-time image restoration of AMD-FLIM through fast parallel data processing by using Threading Building Blocks (TBB; Intel) and octa-core processor (i7-5960x; Intel). Frame rate of 3.8 frames per second was achieved in $1,024{\times}1,024$ resolution with over 4 million lifetime determinations per second and measurement error within 10%. This image acquisition speed is 184 times faster than that of single-channel TCSPC and 9.2 times faster than that of 8-channel TCSPC (state-of-art photon counting rate of 80 million counts per second) with the same lifetime accuracy of 10% and the same pixel resolution.

VISUALIZATION OF THE INTERNAL WATER DISTRIBUTION AT PEMFC USING NEUTRON IMAGING TECHNOLOGY: FEASIBILITY TEST AT HANARO

  • Kim Tae-Joo;Jung Yong-Mi;Kim Moo-Hwan;Sim Cheul-Muu;Lee Seung-Wook;Jeon Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.449-454
    • /
    • 2006
  • Neutron imaging technique was used to investigate the water distribution and movement in Polymer Electrolyte Membrane Fuel Cell (PEMFC) at HANARO, KAERI. The Feasibility tests were performed in the first and second exposure rooms at the neutron radiography facility (NRF) at HANARO in order to check the ability of each exposure room, respectively. The feasibility test apparatus was composed of water and pressurized air before making up the actual test apparatus. Due to the low neutron intensity in the second exposure room, the exposure time was too long to investigate the transient phenomena of PEMFC. Although the exposure time was improved to 0.1 sec in the first exposure room, it was difficult to discriminate detail water movement at the channel due to the high noise level. Therefore, the experimental setup must be optimized according to the test conditions. Water discharge characteristics were investigated under different flow field geometries by using feasibility test apparatus and the neutron imaging technique. The water discharge characteristics of a 3-parallel serpentine are superior to those of a 1-parallel serpentine, but water at Membrane Electrode Assembly (MEA) was not removed, regardless of the flow field type.

Experimental Approach for Water Discharge Characteristics at PEMFC by using Neutron Imaging Technique considered Neutron Flux and Linear Attenuation Coefficient of Thermal Neutron Correction at NRF, HANARO (중성자속 및 선형 흡수 계수 보정을 고려한 중성자영상법을 이용한 PEMFC 내의 물 배출 특성에 관한 실험적 연구)

  • Kim, Tae-Joo;Kim, Jong-Rok;Kim, Moo-Hwan;Sim, Cheul-Muu
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3418-3422
    • /
    • 2007
  • The neutron imaging technique was used to investigate the water discharge characteristics at PEMFC. Prior to investigation of water discharge characteristics, the linear attenuation coefficient for water at Neutron Radiography Facility (NRF) was calibrated. The feasibility test apparatus was consisted of pressurized air and water in order to simulate the actual operating PEMFC. The feasibility tests have been performed at 1-parallel serpentine type with 100 $cm^2$ active area and different air flow rate (1, 2, and 4 lpm). The total water volume variations at each condition were calculated from the neutron images. The water at channel is well discharged as soon as supplying the pressurized air into the PEMFC. However, because the water at MEA isn't removed the total water volume is constant after 150. Therefore more effective method is needed in order to discharge water at MEA, and the neutron imaging technique is helpful for it.

  • PDF

A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique (다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점)

  • Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Kwon, Kyung-Tae;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

Live Electrooptic Imaging Camera for Real-Time Visual Accesses to Electric Waves in GHz Range

  • Tsuchiya, Masahiro;Shiozawa, Takahiro
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.290-297
    • /
    • 2011
  • Recent progresses in the live electrooptic imaging (LEI) technique are reviewed with emphasis on its functionality of real-time visual accesses to traveling electric waves in the GHz range. Together with the principles, configurations, and procedures for the visual observation experiments by an LEI camera system, the following results are described as examples indicating the wide application ranges of the technique; Ku-band waves on arrayed planar antennas, waves on a Gb/s-class digital circuit, W-band waves traveling both in slab-waveguide modes and aerially, backward-traveling wave along composite right/left-handed transmission line, and, waves in monolithic microwave integrated circuit module case.

Comparison of in SENSE and Multiband SENSE technique of the Diffusion tensor using Parallel Imaging (병렬 기법과 다중대역병렬기법간의 유용성 비교)

  • Lee, Ho-Beom;Son, Soon-Yong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2018.05a
    • /
    • pp.61-62
    • /
    • 2018
  • DTI (Diffusion Tensor Imaging)에서는 임상적으로 매우 중요하나 긴 획득시간으로 인하여 적용에 어려움이 있었다. 그러나 최근에 개발된 다중대역병렬기법 (Multiband SENSE)은 동시에 여러 개의 절편을 획득이 가능한 기법으로 기존에 사용되는 병렬기법(SENSE)과 비교하여도 매우 유용한 것을 알 수 있다.

  • PDF