Design and fabrication of Ka-Band Analog Phase Shifter using GaAs Hyperabrupt Junction Varactor Diodes and Reactance Matching (GaAs Hyperabrupt Junction 바랙터 다이오드와 리액턴스 정합을 이용한 Ka-Band 아날로그 위상변화기의 설계)

  • ;Seong-Ik Cho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.5
    • /
    • pp.521-526
    • /
    • 2003
  • This paper describes performance data and design information on a reflection-type analog phase shifter used in Ka-band. Arranging a couple of GaAs hyperabrupt junction varactor diode parallel in a circuit, and applying reactance matching method accordingly, it is possible to 831 a large the phase shift. Design equation is formulated theoretically. Since the assembly process is important in Ka-band, this paper also includes the assembly process that is essential to minimize the generation of parasitic elements during the assembly process. It is obtained variable phase shift 220$^{\circ}$${\pm}$7$^{\circ}$ and insertion loss 5 dB${\pm}$1 dB as a measured result larger than the existing figure in Ka-band.

A Resonance Power Combining Technique Using CRLH-Transmission Line (CRLH 전송 선로를 이용한 공진 기법의 전력 결합 기술)

  • Kim, Ell-Kou;Kim, Young;Kwon, Sang-Keun;Yoon, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.8
    • /
    • pp.673-679
    • /
    • 2009
  • This paper proposes a resonance power-combining technique using CRLH-transmission line. The circuits using proposed technique consist of the parallel capacitances and transmission lines to satisfy matching conditions and to combine power of amplifiers. The CRLH(Composite Right/Lefi-Handed) transmission lines are used to reduce the circuit size. As a result, the power combining amplifier using proposed techniques is measured that a gain is equal and the output power is increased about 2.2 dB higher than the single amplifier. Also, a size of amplifier is 78.3 % smaller than the conventional amplifier using RH transmission line.

DUAL DUTY CYCLE CONTROLLED SOFT-SWITCHING HIGH FREQUENCY INVERTER USING AUXILIARY REVERSE BLOCKING SWITCHED RESONANT CAPACITOR

  • Bishwajit, Saha;Suh, Ki-Young;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.129-131
    • /
    • 2006
  • This paper presents a new ZVS-PWM high frequency inverter. The ZVS operation is achieved in the whole load range by using a simple auxiliary reverse blocking switch in parallel with series resonant capacitor. The operating principle and the operating characteristics of the new high frequency circuit treated here are illustrated and evaluated on the basis of simulation results. It was examined that the complete soft switching operation can be achieved even for low power setting ranges by introducing the high frequency dual duty cycle control scheme. In the proposed high frequency inverter treated here, the dual mode pulse modulation control strategy of the asymmetrical PWM in the higher power setting ranges and the lower power setting ones, the output power of this high frequency inverter could introduce in order to extend soft switching operation ranges. Dual duty cycle is used to provide a wide range of output power regulation that is important in many high frequency inverter applications. It is more suitable for induction heating applications the operation and control principle of the proposed high frequency inverter are described and verified through simulated results.

  • PDF

Enhancement of Power System Transient Stability and Power Quality Using a Novel Solid-state Fault Current Limiter

  • Fereidouni, A.R.;Vahidi, B.;Mehr, T. Hoseini;Doiran, M. Garmroodi
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.474-483
    • /
    • 2011
  • Solid-state fault current limiters (SSFCL) in power systems are alternative devices to limit prospective short circuit currents from reaching lower levels. Fault current limiters (FCL) can be classified into two categories: R-type (resistive) FCLs and L-type (inductive) FCLs. L-type FCL uses an inductor to limit fault level and is more efficient in suppressing voltage drop during a fault. In contrast, R-type FCL is constructed with a resistance and is more effective in consuming the acceleration energy of generators during a fault. Both functions enhance the transient stability of the power system. In the present paper, a novel SSFCL is proposed to enhance power system transient stability and power quality. The proposed SSFCL uses both functions of an L-type and R-type FCL. SSFCL consists of four diodes, one self-turn-off IGCT, a current-limiting by-pass inductor (L), and a variable resistance parallel with an inductor for improvement of power system stability and prevention of over-voltage across SSFCL. The main advantages of the proposed SSFCL are the simplicity of its structure and control, low steady-state impedance, fast response, and the existence of R-type and Ltype impedances during the fault, all of which improve power system stability and power quality. Simulations are accomplished in PSCAD/EMTDC.

The Comparison of the Current Unblance Factor According to the Cable Array Method using PSCAD/EMTDC and FEA (PSCAD/EMTDC와 FEA를 이용한 케이블 배열 방법에 따른 전류 불균형률의 비교)

  • Shin, Ho-Jeon;Kim, Ji-Ho;Kang, Gab-Suk;Kim, Jae-Chul;Lee, Hyang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.2
    • /
    • pp.72-78
    • /
    • 2013
  • In this study, samples from the site where there occurred unbalanced current when cable routing were analyzed, and the simulation program for electric power system analysis, PSCAD/EMTDC, was used to calculate the current unbalance on cable routing. Based on electromagnetic finite element analysis(FEA), electromagnetic parameters enabled the interlocking with COMSOL for the calculation of allowable current ampacity and magnetic filed distribution. This then led to modeling unbalanced current between common modes using the unbalanced current analysis program, thereby comparing and discussing the results from both. The analyzed model is a common mode 2 parallel circuit, which is a basic model for cable routing, and by arranging cables in various ways, the arrangement with the least current unbalance was suggested, which would, in the future, prevent earth faults and extend life for the whole cable.

Analysis on the Operational Characteristic between the Protective devices and Superconducting Fault Current Limiter with a Peak Current Limiting Function in the Power Distribution System (피크전류 제한 기능을 갖는 초전도한류기의 계통 적용에 따른 보호기기간 동작특성 분석)

  • Cho, Yong-Sun;Kim, Jin-Seok;Kim, Jae-Chul;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.11
    • /
    • pp.75-80
    • /
    • 2012
  • In this paper, the operational characteristics due to the introduction of the superconducting fault current limiter(SFCL) with a peak current limiting function were analyzed in the power distribution system. The parallel structure of the superconducting element can operate the peak current limiting function depending on the transient amplitude of fault current. We studied the operating characteristics of the introduction of the SFCL with a peak current limiting function in the power distribution system. Furthermore, we were analyzed between the SFCL with a peak current limiting function and the protection devices in the power distribution system, through the short circuit experiments.

Internet Based Remote Control and Monitoring System using Digital Timer (디지털 타이머를 이용한 인터넷 기반의 원격제어 및 모니터링)

  • Lee Y.G.;Kang S.Y.;Kim E.J.;Bark C.S.;Lim Y.C.;Kim G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.83-88
    • /
    • 2001
  • This paper deals with the economical equipment control which is used by internet network system at the industrial workplace. If the control devices can be accessed by internet, we can have the developed possibility of work conditions. In this paper, we presented the advanced digital timer which has a communication function to control and observe panel to realize control solution based on internet to be easily applicable at workplace with low cost. and we used 485 serial communication module to have parallel expansibility and safety. And, this system was experimented and designed for easy system management and status check from remote station through internet As the result of experiment, the circuit configuration would be more simplified than the existing, and it is expected that multi connection control and monitoring can be simply implemented with low cost equipment at industrial workplace.

  • PDF

Fashion Accessory Design Using Media Art (미디어아트를 이용한 패션 액세서리 디자인)

  • JeKal, Mee;Lee, Youn-Hee
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.4
    • /
    • pp.1-12
    • /
    • 2008
  • The expansion of media art has not only developed the digital technology but also given lots of environmental evolution to improve various fields of design as the main topic of the 21st century. The purpose of this study is aimed at proposing the new design that integrates fashion accessaries with media art technology. This will be done by understanding the social environment in digital ages and studying technology of design based on a variety of literature about changes in our society, neo value, vision, culture and art with fundamental notion of media art. First stage for this study, put an idea into just fashion accessary design because it is not sufficient to incoporate fashion and media art technology. The presented OLED(Organic Light Emitting Diodes) in this study is a kind of display to be in a limelight in the next generation and can be applied to various field of design. media art simultaneously moved into the scope of artistic debates. As a result, we can found that the use of audiovisual introduced numerous new aspects to the conceptual and aesthetic engagement with questions of conception. Today, the presented forms of art and inter-action from the closed -circuit work to interactive media art installations to open process-exist as parallel possibilities.

Steady State and Transient Analysis of Switched Reluctance Motor Drive Fed from a Controlled AC-DC Rectifier

  • Moussa, Mona Fouad
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1495-1502
    • /
    • 2017
  • The Theory of operation of switched reluctance motors (SRM) depends on the reluctance torque, where energy is transferred to stator winding only. Although its construction is simple, the electrical design is complex, due to the switching configuration needed to deliver power to stator coils. However, because of the nonlinearly of magnetic circuit, SRM has torque ripple. This paper proposes a new strategy to drive SRM from a single-phase AC supply. Each stator winding is connected to AC-DC or AC-AC converters, which is called branch. All branches are connected in parallel to a single-phase AC supply. A shaft encoder allows current production in stator winding during the positive torque production region and terminates it during the negative torque production region. A magnetic flux is produced between stator poles when current is supplied from AC supply to stator coil and repeats many cycles as long as the rate of change of stator inductance is positive. Different possibilities for the configurations of AC-AC or AC-DC converters are introduced to drive SRM from the single-phase AC supply. A case study is presented for a SRM fed from AC supply through semi-controlled AC-DC converter is presented. A simulation model is introduced and verified by experimental rig for two-phase SRM.

The Analog-circuited Low-loss Bypass Current Sensing Method for Average Current Mode Control (아날로그 회로로 구현가능한 평균전류제어 저손실 bypass 전류센싱방법)

  • Kim, Seok-Hee;Choi, Byung-Min;Park, Joung-Hu;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.133-138
    • /
    • 2014
  • This paper proposes a low power-loss averaging current mode control using a resistor and bypass switch. Generally, current sensing method using a resistor has a disadvantage of power loss which degrades the efficiency of the entire systems. On the other hand, proposed measurement technique operating with bypass-switch connected in parallel with sensing resistor can reduce power loss significantly the current sensor. An analog-circuited bypass driver is implemented and used along with an average-circuit mode controller. The bypass switch bypasses the sensing current with a small amount of power loss. In this paper, a 50[W] prototype average current mode boost converter has been implemented for the experimental verification.