• Title/Summary/Keyword: Parallel Transmission

Search Result 527, Processing Time 0.039 seconds

Bit-rate Scalable Video Coder Using a $2{\times}2{\times}2$ DCT for Progressive Transmission

  • Woo, Seock-Hoon;Park, Jin-Hyung;Won, Chee-Sun
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.66-69
    • /
    • 2000
  • In this paper, we propose a progressive transmission of a video using a 2$\times$2$\times$2 DCT First of all, the video data is transformed into multiresolution represented video data using a 2$\times$2$\times$2 DCT. Then. it is represented by a 3-D EZT(Embedded Zero Tree) coding fur the progressive transmission with a bit-rate scalability. The proposed progressive transmission algorithm needs much less computations and buffer memories than the higher-order convolution based wavelet filter. Also, since the 2$\times$2$\times$2 DCT requires independent local computations, parallel processing can be applied.

  • PDF

A New Distance Relaying Algorithm Immune to Mutual Coupling Effect and Reactance Effect for 765kV Untransposed Parallel Transmission Lines (상호결합효과와 리액턴스효과를 제거한 765kV 비연가 송전선로 보호용 거리계전 알고리즘)

  • Ahn Yong-Jin;Kang Sang-Hee
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.1
    • /
    • pp.25-30
    • /
    • 2005
  • An accurate digital distance relaying algorithm which is immune to mutual coupling effect and reactance effect of the fault resistance and the load current for the line faults in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-ground fault and phase-to-phase short fault use a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

Integrated GUI Environment of Parallel Fuzzy Inference System for Pattern Classification of Remote Sensing Images

  • Lee, Seong-Hoon;Lee, Sang-Gu;Son, Ki-Sung;Kim, Jong-Hyuk;Lee, Byung-Kwon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.2 no.2
    • /
    • pp.133-138
    • /
    • 2002
  • In this paper, we propose an integrated GUI environment of parallel fuzzy inference system fur pattern classification of remote sensing data. In this, as 4 fuzzy variables in condition part and 104 fuzzy rules are used, a real time and parallel approach is required. For frost fuzzy computation, we use the scan line conversion algorithm to convert lines of each fuzzy linguistic term to the closest integer pixels. We design 4 fuzzy processor unit to be operated in parallel by using FPGA. As a GUI environment, PCI transmission, image data pre-processing, integer pixel mapping and fuzzy membership tuning are considered. This system can be used in a pattern classification system requiring a rapid inference time in a real-time.

New Serial and Parallel Sin+Cos PSS1A PSS Design and Analysis

  • Lee Sang-Seung;Li Shan-Ying;Jang Gwang-Soo;Park Jong-Keun;Moon Seung-Il;Yoon Yong-Tae
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.4
    • /
    • pp.378-384
    • /
    • 2005
  • This paper proposes a new series and parallel Sin+Cos PSS (power system stabilizer) for the purpose of improving the existing PSS1A's performance. The purpose of the PSS is to enhance the damping of power system oscillations through injection of auxiliary signals for an excitation control terminal. The proposed series and parallel Sin+Cos PSS is connected adding the Sin+Cos terms additionally with the serial and parallel connection in a conventional PSS1A. The proposed controller is aimed at considering the damping of oscillation when it changes parameter fluctuations or operational load variations in a power system. The electric power system used is the KEPCO system and the voltage of the power transmission line is 154kV and 345kV. The PSCAD/EMTDC package is used to authorize the effect of the proposed controller. Simulations were shown by and compared with the waveforms for frequency, voltage and electric power.

Parallel Paths in Folded Hyper-Star Graph (Folded 하이퍼-스타 그래프의 병렬 경로)

  • Lee, Hyeong-Ok;Choi, Jung;Park, Seung-Bae;Cho, Chung-Ho;Lim, Hyeong-Seok
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.7
    • /
    • pp.1756-1769
    • /
    • 1999
  • Parallel paths in an interconnection network have some significance in that message transmission time can be reduced because message is divided into packets and transmitted in parallel through several paths, and also an whose nodes has 2n binary bit string, is an interconnection network which has a lower network cost than hypercube and its variation. In this paper, we analyze node disjoint parallel path in Folded Hyper-Star graph FHS(2n,n) proposed as the topology of parallel computers and, using the result, prove that the fault diameter of a Folded Hyper-Star graph FHS(2n,n) is 2n-1.

  • PDF

An Experimental Study on Reduction of Gear Rattle Noise for a Mini-bus with Diesel Engine (디젤엔진을 탑재한 소형버스의 기어 래틀 소음 저감에 관한 실험적 연구)

  • Jung, Jong-An;Cho, Chan-Ki
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.13-21
    • /
    • 1995
  • On mini-bus with diesel engine, at idle rpm for taking measurement to reduce gear rattle noise, was tested by the three clutch disc samples by turns, then measured the fluctuation of revolution of engine & transmission and parallel vibration of differential gear & transmission. By analyzing the measured data, the gear rattle noise, the matching design and tuning technic of transmission are comprehended and established. Conclusions of this test are as follows ; (1) Fluctuation of revolution on transmission is greatly affected by torsion of clutch disc according to fluctuation of engine revolution transmit to transmission through clutch system. Especially, gear rattle noise can be reduced by minimaizing the fluctuation of the revolution of transmission using pre-damper type clutch disc. (2) The reason of gear rattle noise is higher in summer than winter and driving longer period than initial driving is due to affection by drag torque changing. So, it is necessary for manufacturer to choose proper oil to transmission. (3) It can be occurred jumping and crash noise by applying the pre-damper type clutch disc for reducing the gear rattle noise. So, it is necessary to do test with actual vehicle according to test procedure.

  • PDF

Merged-Packet based Effective Queuing Mechanism for Underwater Networks (결합패킷 활용기반 수중네트워크 전송 큐 관리 기법)

  • Shin, Soo Young;Park, Soo-Hyun;Namgung, Jung Il
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.2
    • /
    • pp.61-67
    • /
    • 2017
  • In this paper, an adaptive MAC technique for various underwater environment with narrow-bandwidth and low transmission speed was proposed. In previously published Underwater Packet Flow Control (UPFC) technique, three transmission types (normal, block and parallel transmission) had been proposed using the number of transmission and transmission time. In addition to the UPFC, the proposed technique is an improved version of UPFC having more effective queuing technique for merge transmission. A mathematical model of the proposed queuing theory was constructed and its increased efficiency per unit transmission number was also verified based on simulations.

Suppression of Harmonic Passband of Bandpass Filters(BPFs) Using Parallel-Coupled Mushroom Structure (평행 결합 Mushroom 구조를 이용한 대역 통과 여파기의 고조파 성분 억제)

  • Lee, Jae-Gon;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.118-125
    • /
    • 2007
  • Harmonic band of bandpass filter(BPF) is suppressed using coupled mushroom structure. Between double positive (DPS) transmission line such as microstrip and double negative(DNG) transmission line such as one dimensional mushroom structure, strong coupling broadly arises in the cross range of dispersion curves of isolated microstrip and mushroom structure because of complex propagation constant in the cross range. Strong coupling inhibits wave propagation, so that this kind of structure can be utilized as bandstop filter(BSF). This BSF utilizes coupled transmission line instead of coupled resonator, resulting in broad bandwidth(>30 %), shan-rejection, and high rejection level. The strong coupling between DPS and DNG transmissionline makes it possible shorten coupling length, resulting in compact size. In this paper, parallel coupled BSF having center frequency of 4 GHz and 3 dB fractional bandwidth of 40 % is designed and utilized to suppressed spurious mode of two bandpass filters.

Low Density Parity Check Codes for Hybrid ARQ System

  • Kim, Woo-Tae;Kim, Jeong-Goo;Joo, Eon-Kyeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.4C
    • /
    • pp.370-378
    • /
    • 2007
  • The most appropriate low density parity check (LDPC) code for hybrid automatic repeat request (HARQ) system suitable for future multimedia communication systems is presented in this paper. HARQ system with punctured LDPC code is investigated at first. And two transmission schemes with parallel concatenated LDPC code are also presented and their performances are analyzed according to the various values of mean column weight (MCW). As a result, the parallel concatenated LDPC code with the diversity effect of information bit is considered to be more appropriate for HARQ system considering the throughput as well as error performance.

Analysis of HVDC transmission with parallel AC systems using PACAD/EMTDC (PSCAD/EMTDC를 이용한 HVDC, AC 병행 송전선로 계통해석)

  • Lee, Sangmin;Yoo, Yeuntae;Kim, Hyunwook;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.217-218
    • /
    • 2015
  • This paper presents an anaysis of parallel operated HVDC and AC transmissions' transient stability and control analysis by using PACAD/EMTDC program. We measured and analyzed power trasfer in case of various operating conditions including ac, dc faults to find an effects to the power system of the operating conditions. In this project, Simulation of ac/dc parallel system that maximize margins of the ac system and allow a higher power transfer is performed and analyzed.

  • PDF