• Title/Summary/Keyword: Parallel Testing

Search Result 231, Processing Time 0.031 seconds

Simple Identification of Symmetric Reduction in Unilateral Depressed Zygomatic Fracture (일측성 광대뼈골절 환자에서 수평계와 자를 이용한 변위 교정의 간단한 파악법)

  • Yi, Hyung-Suk;Lee, Kyung-Suk;Kim, Jun-Sik;Kim, Nam-Gyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.2
    • /
    • pp.195-198
    • /
    • 2010
  • Purpose: The zygoma is a key element which composes the facial contour. Zygomatic fracture induces facial asymmetry. We use radiologic evaluation or inspections mainly for identification of symmetry after reduction depressed zygomatic fracture. But the disadvantages of such methods are time-consuming and complicated process. So we tried to develop a new testing method with a ruler and a level. Methods: In unilateral depressed zygomatic fracture patient, parallel to the patient's head to make sure lay horizontaly. Put the leg of a ruler on the malar eminence so that it is at the same distance from the facial midline. Then take the level of malar eminence as put the level above the ruler. This process was performed before and after the reduction. Results: We were able to fix with plate and screw after checking the results of reduction fast and easily. Good results were obtained at post-operative radiologic evaluation. Conclusion: We can easily get the ruler and level around life. This method is not only simple but also shorttime process compared with other method-radiologic evaluation or inspection. And the operator can explain the results to the patients easily and objectively. Authors obtained the good results with this new method, and would introduce it for another method of identifying the result of reduction in depressed zygomatic fractures.

Automatic Optimization Methods for Image Processing Programs Using OpenCL (OpenCL을 이용한 이미지 처리 프로그램의 자동 최적화 방법)

  • Shin, Jaeho;Jo, Gangwon;Lee, Ilkoo;Lee, Jaejin
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.3
    • /
    • pp.188-193
    • /
    • 2017
  • In this paper, we propose automatic OpenCL optimization techniques that offer the best performance for image processing programs on any hardware system. Developers should seek a proper way of parallelization and an appropriate work-group size for the architecture of target compute devices to achieve the best performance. However, testing potential devices to find them is both time-consuming and costly. Our techniques automatically set up hardware-optimized parallelization and find a suitable work-group size for the target device. Furthermore, using OpenCL does not always provide better performance in image processing. Hence, we also propose a way to automatically search for a threshold image size to allow image processing programs to decide whether or not to use OpenCL. Our findings demonstrate that out techniques improve the image processing performance significantly.

A comparison of the shear bond strength between porcelain repair systems and fractured surface of porcelain-fused-to-metal restorations (도재파절 양상에 따른 수종의 도재 수복용 레진의 결합력에 관한 실험적 연구)

  • Choi, Jeung Won;Han, Dong Hoo;Jeong, Chang Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.147-163
    • /
    • 1990
  • Although dental porcelain demonstrates lasting esthetic results, it suffers from inherent brittle fractures. Various techniques and materials for intraoral porcelain repair has been suggested. This study investigated the in vitro shear strength of three porcelain repair systems according to aspects of the porcelain fractures. The purpose of this study was to evaluate the shear bond strength of three porcelain repair systems(All-bond, Clearfil, Scotchprime) according to fractured surface of porcelain - fused - to - metal restorations. For this study specimens were divided into five groups : group 1 represented fracture occurred at body porcelain layer, group 2 represented fracture occurred at opaque porcelain layer, group 3 represented fracture including 1/3 of metal exposure, group 4 represented fracture including 2/3 of metal exposure, and group 5 represented all metal surface was exposed. Specimens were stored in double deionized water(24Hr, $37^{\circ}C$) and thermocycling was performed(24Hr, 1080cycles), and subjected to a shear force parallel to the repair resin and porcelain interface by use of an University Testing Machine. The results of this study were obtained as follows : 1. In group 1 and 2, bond strength was relatively high, and bond strength showing reducing tendency as exposure of metal was increased. 2. In group 1, bond strength was relatively high, and no significant differences in porcelain repair system. 3. In group 2, 3 and 4, All-bond and Clearfil provided significantly higher bond strength than scotchprime. 4. In group 5, bond strength was the lowest among all groups and especially in case if Scotchprime. 5. Cohesive failure was observed in group 1 and 2, adhesive failure was observed in group 5, and cohesive / adhesive failures were observed in group 3 and 4.

  • PDF

Noninvasive prenatal test for the pregnancy with Turner syndrome mosaicism 45, X/47, XXX: A case report

  • Kim, Ji Hye;Lee, Gun Ho;Cha, Dong Hyun;Cho, Eun-Hae;Jung, Yong Wook
    • Journal of Genetic Medicine
    • /
    • v.12 no.2
    • /
    • pp.118-122
    • /
    • 2015
  • Noninvasive prenatal test (NIPT) is a novel screening method for the diagnosis of fetal chromosomal aneuploidies. NIPT is based on technology that detects cell-free fetal DNA in maternal plasma and analyzes it with massively parallel sequencing technology to determine whether the fetus is at risk of trisomy 21, trisomy 18, trisomy 13 or sex chromosome abnormalities (SCAs). NIPT has been reported to have sensitivity of 99% and a false positive rate of less than 1% for detecting trisomy 21 and trisomy 18. Although extension of the application of NIPT to other SCAs has been attempted, there are concerns in extending NIPT to SCAs because of maternal or fetal mosaicism, undetected maternal SCAs, and multiple pregnancies. Recently, we assessed a pregnancy with the rare Turner syndrome mosaicism 45, X/47, XXX, which was reported as 45, X with NIPT. We present the case here and briefly review the current literatures on NIPT in testing for fetal monosomy X. To the best of our knowledge, this is the first report of the 45, X/47, XXX mosaicism in Korea to be reported as 45, X by NIPT with whole genome sequencing. This case report will provide valuable information for counseling women who want to undergo NIPT.

Design and Implementation of the Performance Driven UI-Mashup Architecture (성능 주도의 UI-Mashup 아키텍처의 설계 및 구현)

  • Cho, Dong-Il
    • Journal of Internet Computing and Services
    • /
    • v.15 no.1
    • /
    • pp.45-53
    • /
    • 2014
  • UI-Mashup is widely used as a service method to add value, which is composed of distributed various contents on the internet and has turned out to be one of the latest trends in web application program development. Previous UI-Mashup-related studies have focused primarily on the dynamic service composition and have not been able to adapt to a rapidly changing Web Standard, thusthe end users conclude that UI-Mashups are slow, incompatible and poor security services. In this study, We propose an architecture for the performance improvements of UI-Mashup.In order to provide fast services and security enhancements, the proposed architecture collects UI fragments on the server in parallel, and sends layouts and contents of Mashups UI to the client through a special delivery channel supporting fast reaction and response time. In this study, the implementation and performance tests were proceeded to verify the proposed architecture experimentally. As a result of the performance testing, the proposed architecture has two to three times faster response time and more than four times throughput compared to the previous UI-Mashup technology.

Comparison of changes in retentive force of three stud attachments for implant overdentures

  • Kim, Su-Min;Choi, Jae-Won;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.303-311
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the changes in retentive force of stud attachments for implant overdentures by in vitro 2-year-wear simulation. MATERIALS AND METHODS. Three commercially available attachment systems were investigated: Kerator blue, O-ring red, and EZ lock. Two implant fixtures were embedded in parallel in each custom base mounting. Five pairs of each attachment system were tested. A universal testing machine was used to measure the retentive force during 2500 insertion and removal cycles. Surface changes on the components were evaluated by scanning electron microscopy (SEM). A Kruskal-Wallis test, followed by Pairwise comparison, was used to compare the retentive force between the groups, and to determine groups that were significantly different (${\alpha}$<.05). RESULTS. A comparison of the initial retentive force revealed the highest value for Kerator, followed by the O-ring and EZ lock attachments. However, no significant difference was detected between Kerator and O-ring (P>.05). After 2500 insertion and removal cycles, the highest retention loss was recorded for O-ring, and no significant difference between Kerator and EZ lock (P>.05). Also, Kerator showed the highest retentive force, followed by EZ lock and O-ring, after 2500 cycles (P<.05). Based on SEM analysis, the polymeric components in O-ring and Kerator were observed to exhibit surface wear and deformation. CONCLUSION. After 2500 insertion and removal cycles, all attachments exhibited significant loss in retention. Mechanism of retention loss can only be partially explained by surface changes.

Magnetorheological elastomer base isolator for earthquake response mitigation on building structures: modeling and second-order sliding mode control

  • Yu, Yang;Royel, Sayed;Li, Jianchun;Li, Yancheng;Ha, Quang
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.943-966
    • /
    • 2016
  • Recently, magnetorheological elastomer (MRE) material and its devices have been developed and attracted a good deal of attention for their potentials in vibration control. Among them, a highly adaptive base isolator based on MRE was designed, fabricated and tested for real-time adaptive control of base isolated structures against a suite of earthquakes. To perfectly take advantage of this new device, an accurate and robust model should be built to characterize its nonlinearity and hysteresis for its application in structural control. This paper first proposes a novel hysteresis model, in which a nonlinear hyperbolic sine function spring is used to portray the strain stiffening phenomenon and a Voigt component is incorporated in parallel to describe the solid-material behaviours. Then the fruit fly optimization algorithm (FFOA) is employed for model parameter identification using testing data of shear force, displacement and velocity obtained from different loading conditions. The relationships between model parameters and applied current are also explored to obtain a current-dependent generalized model for the control application. Based on the proposed model of MRE base isolator, a second-order sliding mode controller is designed and applied to the device to provide a real-time feedback control of smart structures. The performance of the proposed technique is evaluated in simulation through utilizing a three-storey benchmark building model under four benchmark earthquake excitations. The results verify the effectiveness of the proposed current-dependent model and corresponding controller for semi-active control of MRE base isolator incorporated smart structures.

Effect of Specimen Orientation on Fatigue Crack Growth Behavior in Friction Stir Welded Al7075-T651 Joints (마찰교반용접된 Al7075-T651 용접부의 피로균열전파 거동에 미치는 시험편 채취방향의 영향)

  • Jeong, Yeui Han;Kim, Seon Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1317-1323
    • /
    • 2014
  • The aim of this paper is to investigate the effects of crack orientation on fatigue crack growth behavior in friction stir welded (FSWed) Al 7075-T651. Fatigue crack growth testing was conducted on compact tension (CT) specimens machined from the friction stir welds and the base metal under constant stress intensity factor range control. Tests were performed with the crack propagating nominally perpendicular to the weld line (termed the TL specimen) and the crack propagating in a parallel direction of the weld line (termed the LT specimen), and with three different constant stress intensity factor ranges. Both these specimen orientations were found to have a considerable effect on the fatigue crack growth behavior. Paris's law was adopted for the analysis of experimental results; the exponent m of the WM-LT specimen was determined to be 3.56, which was the largest value in this experimental conditions.

A Study on Velocity-Log Conductivity, Velocity-Head Cross Covariances in Aquifers with Nonstationary Conductivity Fields (비정체형 지하대수층의 속도-대수투수계수, 속도-수두 교차공분산에 관한 연구)

  • Seong, Gwan-Je
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.4
    • /
    • pp.363-373
    • /
    • 1998
  • In this study, random flow field in a nonstationary porous formation is characterized through cross covariances of the velocity with the log conductivity and the head. The hydraulic head and the velocity in saturated aquifers are found through stochastic analysis of a steady, two-dimensional flow field without recharge. Expression for these cross covariances are obtained in quasi-analytic forms all in terms of the parameters which characterize the nonstationary conductivity field and the average head gradient. The cross covariances with a Gaussian correlation function for the log conductivity are presented for two particular cases where the trend is either parallel or perpendicular to the mean head gradient and for separation distances along and across the mean flow direction. The results may be of particular importance in transport predictions and conditioning on field measurements when the log conductivity field is suspected to be nonstationary and also serve as a benchmark for testing nonstationary numerical codes. Keywords : cross covariance, nonstationary conductivity field, saturated aquifer, stochastic analysis.

  • PDF

Pipe Stiffness Prediction of GRP Flexible Pipe (GRP 연성관의 관강성 예측)

  • Lee, Young-Geun;Kim, Sun-Hee;Park, Joon-Seok;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.18-24
    • /
    • 2011
  • In this paper, we present the load-deflection behavior of GRP pipes. GRP buried pipes are widely used in construction in the advantage of their superior mechanical and physical characteristics such as high chemical resistance, high corrosion resistance, right weight, smooth surface of the pipe, and cost effectiveness from soil-structure interaction. To design flexible pipes to be buried underground, it should be based on the ASTM D2412(2010). When applying ASTM D 2412(2010) to the design, pipe stiffness(PS) must be predetermined by the parallel-plate test which requires tedious and laborious working process. To overcome such problems, the finite element simulations for finding the load-deflection behavior of the GRP flexible pipes is installed at UTM testing machine. In the finite element simulations, basic data, such as the modulus of elasticity of the material and cross-sectional dimension, is used. From the investigation, we found that the difference between experimental result and analytical prediction is less than 15% when the pipe deflected 3% and 5% of its vertical diameter although the pipe material is not uniform across the cross-section.