• Title/Summary/Keyword: Parallel Reference Correlation

Search Result 9, Processing Time 0.033 seconds

An Identification Method of Radar Signals using Parallel Processor (병렬프로세서를 활용한 레이더 신호의 식별)

  • Kim, Gwan-Tae;Ju, Young-Kwan;Park, Sang-Hwan;Jeon, Joongnam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.75-80
    • /
    • 2017
  • ES (Electronic Warfare Support System) collects radar signals, and analyzes the signals about frequency, pulse width, PRI (Pulse Repetition Interval), and etc. and then ES compares analyzed result with known radar signals to identify them. But there are two disadvantage. One is that use of known radar signals is in comparing step only. The other is that calculating PRI needs many operations. In this paper proposes a parallel reference correlation algorithm that uses GPGPU (General Purpose Graphics Processing Units) and can identify what signals are in received radar signals without calculating PRI.

Orthogonal Reception Characteristics for the DS/SS Signals with Time-shifted m-Sequences

  • Baek Kyung Hoon;Hyun Kwang Min;Yoon Dong Weon;Park Sang Kyu
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.658-662
    • /
    • 2004
  • This paper proposes an orthogonal reception structure for OS/SS communication with time-shifted m-sequences, and compares the performances of the proposed and conventional receiver. This structure provides two important characteristics to reference user signal with not only increment of auto-correlation value but also cancel of the cross-correlation value out to zero between the reference user and other user signals. In addition, the structure can be easily implemented with the conventional receiver adding an additional integrator path in parallel and an adder that sums the conventional path output and the new path output signal. Hence, the proposed structure can be applied for channel impulse response measurement, and efficiently used for multi-user interference signal cancellation and channel capacity increment by flexible structural inter-working operation, connection or disconnection, of the new path to conventional receiver structure.

  • PDF

Correlation between Velocity Fluctuation and Fluctuation of Hydrogen Concentration in 2-D Air-Hydrogen Supersonic Mixing Layer

  • Sakima, Fuminori;Arai, Takakage;Edward, Shelley-R.;Mori, Yuko
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.111-116
    • /
    • 2004
  • An experiment was carried out to confirm the validity of time series evaluation of supersonic mixing condition by using catalytic reaction on a platinum wire. Geseous hydrogen was injected parallel to supersonic freestream (M$\infty$ $\approx$ 1.81) from a slit injector, which was located at backward facing step. Time series condition of supersonic mixing was evaluated by using W-type probe which has a platinum wire and reference wire (nickel wire). The evaluation was by simultaneously measuring each electric circuit which kept the temperature of wire constant. Investigations were also conducted for helium, air and no secondary injectant cases to compare with the hydrogen injectant case. The results indicated that it was possible to measure the time series behavior of air and hydrogen supersonic mixing layer or coherent motion of turbulence by using this evaluation.

  • PDF

A STUDY ON THE OCCLUSAL PLANE INCLINATION IN LATERAL CEPHALOGRAPH (교합평면 경사도에 관한 두부방사선학적 연구)

  • Lee, Sung-Youn;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.21 no.2 s.34
    • /
    • pp.367-397
    • /
    • 1991
  • This study was aimed to investigate the occlusal plane inclination in relation to the skeletal and dental assessment measurements in order to provide a reference in orthodontic treatment planning as the occlusal plane should be reconstructed orthodontically or gnathologically. The sample consisted of 73 normal occlusions and 113 malocclusions of adults. The computerized statistical analysis of 38 occlusal plane's and 29 skeletal and dental measurements were carried out with SPSS. The conclusions were as follows; 1 In normal occlusion, COP-NaPog was average $83.63^{\circ}$ (2.44) and occlusal plane inclination had a strong negative correlation with SNB and FH-NaPog. 2. In normal occlusion, ArANS plane was nearly parallel to the occlusal plane. 3. In malocclusion, the larger the mandibular plane angle and the shorter the ramus height was, the more downward the occlusal plane had a tendency to tip anteriorly. 4. Occlusal plane was more horizontal in deep bite group, while it was steeper in openbite group. 5. The curve of Spee was severe in deep bite group but in openbite group mandibular occlusal plane showed average reverse curvature, where it was found that the configuration of the occlusal plane contributed to the excess or deficiency of anterior overbite.

  • PDF

Evaluation of the Forest Bird Community in the Breeding Season by using the Sound Recording System (산림성 조류의 번식기 음성녹음을 이용한 조류군집 평가)

  • Yoo, Seung-Hwa;Han, Hyun-Jin;Kim, Dong-Won;Joo, Woo-Young
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.1
    • /
    • pp.39-46
    • /
    • 2018
  • Breeding bird surveys provide the reference information for understanding bird community structure and function in the ecosystem and conserving biodiversity. Recent rapid change of biodiversity due to climate change and other factors has made it necessary to utilize acoustic sensors for accuracy and spatial expansion of forest bird survey data and for time-series monitoring of forest birds. The objective of this study is to investigate the possibility of using acoustic recording sensor to evaluate the diversity of forest birds at breeding season by comparing and analyzing the recorded data of bird songs and field bird survey data. We conducted the site survey and recording in 186 points in 48 areas of 4 regions of Gombaeryeong and Jochimryeong around Jeombongsan Mountain and Jugryeong and Gochiryeong around Sobaeksan Mountain from May 2nd to 16th in 2013. The analysis of the correlation between the recording result and Bird Community Index based on the field survey showed that the number of bird species, population, and the number of bird songs by recording was significantly correlated to the number of species and population by field survey. Moreover, the number of bird species and the number of bird songs by recording showed a significant correlation to species diversity and species richness but no or low significant correlation to species evenness by the field study (observation and listing in parallel). As a result, it was possible to check species composition and species diversity of bird communities by analyzing acoustic recording data on the field. The acoustic recordings of bird songs in the breeding period were more reliable than the non-breeding period in the correlation of recording result and species diversity and for utilization.

Cephalometrically assessing the validity of superior, middle and inferior tragus points on ala-tragus line while establishing the occlusal plane in edentulous patient

  • Chaturvedi, Saurabh;Thombare, Ram
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.58-66
    • /
    • 2013
  • PURPOSE. The purpose of this study was to decide the most appropriate point on tragus to be used as a reference point at time of marking ala tragus line while establishing occlusal plane. MATERIALS AND METHODS. The data was collected in two groups of subjects: 1) Dentulous 2) Edentulous group having sample size of 30 for each group with equal gender distribution (15 males, 15 females each). Downs analysis was used for base value. Lateral cephalographs were taken for all selected subjects. Three points were marked on tragus as Superior (S), Middle (M), and Inferior (I) and were joined with ala (A) of the nose to form ala-tragus lines. The angle formed by each line (SA plane, MA plane, IA plane) with Frankfort Horizontal (FH) plane was measured by using custom made device and modified protractor in all dentulous and edentulous subjects. Also, in dentulous subjects angle between Frankfort Horizontal plane and natural occlusal plane was measured. The measurements obtained were subjected to the following statistical tests; descriptive analysis, Student's unpaired t-test and Pearson's correlation coefficient. RESULTS. The results demonstrated, the mean angle COO (cant of occlusal plane) as $9.76^{\circ}$, inferior point on tragus had given the mean angular value of IFH [Angle between IA plane (plane formed by joining inferior point-I on tragus and ala of nose- A) and FH plane) as $10.40^{\circ}$ and $10.56^{\circ}$ in dentulous and edentulous subjects respectively which was the closest value to the angle COO and was comparable with the values of angle COO value in Downs analysis. Angulations of ala-tragus line marked from inferior point with occlusal plane in dentulous subject had given the smallest value $2.46^{\circ}$ which showed that this ala-tragus line was nearly parallel to occlusal plane. CONCLUSION. The inferior point marked on tragus is the most appropriate point for marking ala-tragus line.

Utility of CoaguChek XS for Monitoring the Prothrombin Time (프로트롬빈시간 모니터링을 위한 CoaguChek XS의 유용성)

  • Park, Rojin;Kim, Yong-Hyun;Kwon, Kyung Ock;Na, Jongsung;Won, Yong Soon;Sung, Ki Bum;Lee, Nae-Hee;Choi, Tae Youn;Shin, Jeong Won;Shin, Hee Bong;Lee, Yong-Wha;Lee, You Kyeong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.6
    • /
    • pp.471-475
    • /
    • 2008
  • Background: In order to achieve a maintenance level and to prevent hemorrhagic complications, regular monitoring of the INR is mandatory for patients on oral anticoagulation therapy (OAT). A point-of-care instrument for INR monitoring is convenient for users, but the accuracy of the results has been controversial, and so this calls for exact evaluation of the point-of-care instrument that is used for INR monitoring. Methods: From Aug 2007 through Feb 2008, 85 patients on OAT among the all the patients who were admitted to Soonchunhyang University Bucheon Hospital were involved in this study. Parallel measurements of the PT INR were performed using a CoaguChek-XS and, a CA-7000 laboratory reference instrument and the results were analyzed. In addition, the patients' clinical data, including the diagnosis and the frequency and interval of the INR measurements, were also analyzed. Results: Of the 85 patients, 25 were admitted more than once to undergo INR testing and the mean interval between testing was 8.6 weeks with 39% and 38% of the tests being less than INR 2 units with using the CoaguChek-XS and the reference method, respectively. The coefficients of variation of CoaguChek-XS were 4.50 and 2.45 for the high and low INR patients, respectively. An excellent correlation was found between the two methods with a $R^2$ of 0.966 (p<0.001). Through Bland-Altman analysis, the mean INR difference between the two methods was 0.13 with the limit of agreement being -0.47~+0.72 with a 95% confidence interval. CoaguChek-XS was shown to overestimate the INR value for patients with an increasing INR, as compared to the reference method. Conclusion: CoaguChek-XS demonstrated great precision and accuracy for patients on OAT when compared to the laboratory INR results. Accordingly, the instrument should help to monitor the INR in the patients on OAT.

Fabrication of the Noninvasive Tube Voltage Meter of Radiotherapy Simulator and Its Performance Analysis (방사선치료 시뮬레이터의 비접속형관전압계 제작과 성능분석)

  • Kim, Jong-Eon;Yoon, Chun-Sil;Kim, Sung-Hyun;Park, Chang-Hee;Cha, Byung-Youl
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.201-206
    • /
    • 2006
  • In this study, we have fabricated the noninvasive tube voltage meter which can observe the waveform of tube voltage and measure the tube voltage by using the Intensity of X-ray beam irradiated from radiotherapy simulator and also investigated the feasibility for clinical applications. Two pin photodiodes acting as X-ray detectors were arranged in parallel at the position of ${\pm}1.4cm$ in the y-axis of X-ray field and the aluminum filters with different thickness were placed above them. Using this detector, we could get the ratio ($r_{eff}$) of the relative output voltage which is proportional to the thickness of the filters. And the logarithm of effective peak tube voltage ($InkV_{p,eff}$) was obtained by Victoreen's NERO 6000M used as reference tube voltage meter. From the linear regression analysis of $r_{eff}$ and In $kV_{p,eff}$ the correlation coefficient (r) of linear equation was obtained to be 0.996 for the calibration of the tube voltage meter. Therefore, we suggest that the noninvasive tube voltage meter fabricated in this study can be used for clinical applications due to Its high accuracy.

  • PDF

A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION (임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구)

  • Kim Pyung-Il;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.