• Title/Summary/Keyword: Parallel Projection

Search Result 116, Processing Time 0.022 seconds

Fast Motion Artifact Correction Using l$_1$-norm (l$_1$-norm을 이용한 움직임 인공물의 고속 보정)

  • Zho, Sang-Young;Kim, Eung-Yeop;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.22-30
    • /
    • 2009
  • Purpose : Patient motion during magnetic resonance (MR) imaging is one of the major problems due to its long scan time. Entropy based post-processing motion correction techniques have been shown to correct motion artifact effectively. One of main limitations of these techniques however is its long processing time. In this study, we propose several methods to reduce this long processing time effectively. Materials and Methods : To reduce the long processing time, we used the separability property of two dimensional Fourier transform (2-D FT). Also, a computationally light metric (sum of all image pixel intensity) was used instead of the entropy criterion. Finally, partial Fourier reconstruction, in particular the projection onto convex set (POCS) method, was combined thereby reducing the size of the data which should be processed and corrected. Results : Time savings of each proposed method are presented with different data size of brain images. In vivo data were processed using the proposed method and showed similar image quality. The total processing time was reduced to 15% in two dimensional images and 30% in the three dimensional images. Conclusion : The proposed methods can be useful in reducing image motion artifacts when only post-processing motion correction algorithms are available. The proposed methods can also be combined with parallel imaging technique to further reduce the processing times.

  • PDF

The Crystal and Molecular Structure of Sulfaguanidine Monohydrate (Sulfaguanidine Monohydrate의 結晶 및 分子構造)

  • Koo, Chung-Hoe;Kim, Hoon-Sup;Shin, Whan-Chul;Choe, Chu-Hyn
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.2
    • /
    • pp.97-109
    • /
    • 1974
  • The crystal and molecular structure of sulfaguanidine monohydrate, $C_7H_{10}N_4O_2S{\cdot}H_2O$, was determined from visually estimated intensity data from Weissenberg photographs. The crystal data are monoclinic, space group $P2_1$/c with four molecules in a unit cell of dimensions, ${\alpha}=7.57{\pm}0.03,\;b=5.44{\pm}0.02,\;c=24.76{\pm}0.06{\AA},\;{\beta}=91.0{\pm}0.2^{\circ}$. The structure has been solved by an interpretation of a Patterson map and with a help of a direct procedure on a projection. The parameters were refined isotropically by block-diagonal least-squares methods using 1542 observed independent reflections to give R = 0.14. By hydrogen bonding a guanidyl nitrogen of a sulfaguanidine molecule is linked to the sulfonyl oxygens of the other molecules indirectly through two different water molecules. The role of water molecule is both a donor and an acceptor in hydrogen-bonding formation and these hydrogen bonds are tetrahedrally oriented. The hydrogen-bonding networks form infinite molecular layers parallel to (001) plane.

  • PDF

Correction of Retracted Ala Using Spacer Graft in Secondary Cleft Lip and Nose Deformity (이차 구순비 변형 환자에서 Spacer Graft를 이용한 콧방울뒤당김(retracted ala)의 교정)

  • Han, Kyu-Seok;Choi, Hyun-Gon;Shin, Dong-Hyeok;Kim, Soon-Heum;Hwang, Eun-A;Uhm, Ki-Il
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.376-382
    • /
    • 2011
  • Purpose: In patients with unilateral cleft lip and nose deformity, alar retraction is commonly seen on the non-cleft side after cleft side is corrected. Spacer graft was used to drag down the inferior border of the alar cartilage of the non-cleft side so as to match the cleft side. By performing spacer graft and septal extension graft together, symmetry and cosmetic improvements were achieved. Methods: Seven unilateral cleft lip and nose deformity patients underwent surgery for alar retraction correction. The median age was 24 years (ranged from 15 to 34 years), and the median follow-up period was 7.4 months (ranged from 6 to 12 months). The perpendicular length from the longitudinal axis of the nostril to the alar rim, the nasolabial angle and the ala-labial angle were measured in the lateral view photo. The longest perpendicular length from the cephalic border of the alar rim to the parallel line of the alar base was measured in the frontal view photo. Results: Improvement in alar retraction was seen after the surgery. There were no specific complications during the follow-up and the symmetry of both nostrils was satisfactory. No increase in the nasolabial angle or exposure of the nostrils was seen after the tip projection via tip plasty. Conclusion: The fundamental factor in correcting alar retraction with secondary cleft lip and nose deformity is repositioning the alar rim with spacer graft, which seems to be more physiologic than other methods. The method combining spacer graft with septal extension graft will bring symmetry as well as more cosmetic improvement in correction of alar retraction with secondary cleft lip and nose deformity.

Double-Gauss Optical System Design with Fixed Magnification and Image Surface Independent of Object Distance (물체거리가 변하여도 배율과 상면이 고정되는 이중 가우스 광학계의 설계)

  • Ryu, Jae Myung;Ryu, Chang Ho;Kim, Kang Min;Kim, Byoung Young;Ju, Yun Jae;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.1
    • /
    • pp.19-27
    • /
    • 2018
  • A change in object distance would generally change the magnification of an optical system. In this paper, we have proposed and designed a double-Gauss optical system with a fixed magnification and image surface regardless of any change in object distance, according to moving the lens groups a little bit to the front and rear of the stop, independently parallel to the direction of the optical axis. By maintaining a constant size of image formation in spite of various object-distance changes in a projection system such as a head-up display (HUD) or head-mounted display (HMD), we can prevent the field of view from changing while focusing in an HUD or HMD. Also, to check precisely the state of the wiring that connects semiconductor chips and IC circuit boards, we can keep the magnification of the optical system constant, even when the object distance changes due to vertical movement along the optical axis of a testing device. Additionally, if we use this double-Gauss optical system as a vision system in the testing process of lots of electronic boards in a manufacturing system, since we can systematically eliminate additional image processing for visual enhancement of image quality, we can dramatically reduce the testing time for a fast test process. Also, the Gaussian bracket method was used to find the moving distance of each group, to achieve the desired specifications and fix magnification and image surface simultaneously. After the initial design, the optimization of the optical system was performed using the Synopsys optical design software.

Implementation of RSA modular exponentiator using Division Chain (나눗셈 체인을 이용한 RSA 모듈로 멱승기의 구현)

  • 김성두;정용진
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.12 no.2
    • /
    • pp.21-34
    • /
    • 2002
  • In this paper we propos a new hardware architecture of modular exponentiation using a division chain method which has been proposed in (2). Modular exponentiation using the division chain is performed by receding an exponent E as a mixed form of multiplication and addition with divisors d=2 or $d=2^I +1$ and respective remainders r. This calculates the modular exponentiation in about $1.4log_2$E multiplications on average which is much less iterations than $2log_2$E of conventional Binary Method. We designed a linear systolic array multiplier with pipelining and used a horizontal projection on its data dependence graph. So, for k-bit key, two k-bit data frames can be inputted simultaneously and two modular multipliers, each consisting of k/2+3 PE(Processing Element)s, can operate in parallel to accomplish 100% throughput. We propose a new encoding scheme to represent divisors and remainders of the division chain to keep regularity of the data path. When it is synthesized to ASIC using Samsung 0.5 um CMOS standard cell library, the critical path delay is 4.24ns, and resulting performance is estimated to be abort 140 Kbps for a 1024-bit data frame at 200Mhz clock In decryption process, the speed can be enhanced to 560kbps by using CRT(Chinese Remainder Theorem). Futhermore, to satisfy real time requirements we can choose small public exponent E, such as 3,17 or $2^{16} +1$, in encryption and verification process. in which case the performance can reach 7.3Mbps.

Study on Tumor Control Probability and Normal Tissue Complication Probability in 3D Conformal Radiotherapy (방사선 입체조형치료에 대한 종양치유확율과 정상조직손상확율에 관한 연구)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.227-245
    • /
    • 1998
  • A most appropriate model of 3-D conformal radiotherapy has been induced by clinical evaluation and animal study, and therapeutic gains were evaluated by numerical equation of tumor control probability(TCP) and normal tissue complication probability (NTCP). The radiation dose to the tumor and the adjacent normal organs was accurately evaluated and compared using the dose volume histogram(DVH). The TCP and NTCP was derived from the distribution of given dosage and irradiated volume, and these numbers were used as the biological index for the assessment of the treatment effects. Ten patients with liver disease have been evaluated and 3 dogs were sacrificed for this study. Based on the 3-D images of the tumor and adjacent organs, the optimum radiation dose and the projection direction which could maximize the radiation effect while minimizing the effects to the adjacent organs could be decided. 3). The most effective collimation for the normal adjacent organs was made through the beams eye view with the use of multileaf collimator. When the dose was increased from 50Gy to 70Gy, the TCP for the conventional 2-port radiation and the 5-port multidimensional therapy was 0.982 and 0.995 respectively, while the NTCP was 0.725 and 0.142 respectively, suggesting that the 3-D conformal radiotherapy might be the appropriate therapy to apply sufficient radiation dose to the tumor while minimizing the damages to the normal areas of the liver. Positive correlation was observed between the NTCP and the actual complication of the normal liver in the animal study. The present study suggest that the use of 3-D conformal radiotherapy and the application of the mathematical models of TCP and NTCP may provide the improvements in the treatment of hepatoma with enhanced results.

  • PDF