• Title/Summary/Keyword: Parallel Plane plate

Search Result 58, Processing Time 0.022 seconds

Design and Near-Field Analysis of X-Band Linear/Circular Polarizer (X-밴드 선형/원형 편파 변환기의 설계 및 근거리장 해석)

  • 서창용;정명수;박동철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.8
    • /
    • pp.801-808
    • /
    • 2004
  • In this paper, we proposed the grating parallel plate waveguide structure for converting a linearly polarized wave to a circularly polarized wave. For the design of the polarizer, the moment method and Floquet's theorem are applied under two assumptions that the incident wave is a plane wave and the structure is infinitely periodic. In order for the more precise design, we performed the near-field analysis for the finite polarizer structure using MATLAB. By comparing with the measured results obtained by the near-field arrangement, we verified the correctness of our near-field analysis. By taking the ideal assumptions considered in the initial design procedure into account, newly designed modified dimensions for the polarizer was suggested which give improved performance.

Position Control of the Two Links Inverted Pendulum with a Time Varying Load on the Top (상부 시변 부하를 갖는 2축 도립진자의 위치 제어)

  • 이건영
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.9
    • /
    • pp.1147-1153
    • /
    • 1999
  • The attitude control of a double inverted pendulum with a periodical disturbance at link top is dealt in this paper. The proposed system is consisted of the double inverted pendulum and a disturbing link; a triple inverted pendulum with two motors. The lower link is hinged on the plate to free for rotation in the vertical plane. The upper link is connected to the lower link through a DC motor. The DC motor is used to control the posture of the pendulum by adjusting the position of the upper link. The periodical disturbance can be generated by the additional like attached at the end of link 2 through another DC motor, which is the modeling of a posture for a biped supporting with one leg. The motor for the joint simulates the knee joint(or hip joint) and the disturbance for the legs moving in air. The algorithm for controlling the proposed inverted pendulum which is regarded as a virtual double inverted pendulum with a periodic disturbance, is consisted of a state feedback control and a fuzzy logic controller connected in parallel. The fuzzy controller keeps the center of gravity of the biped within the specified range through the nonlinear feedback compensator. The state feedback control takes over the role to maintain a desired posture regardless the disturbance at the link top. Simulations with a mathematical model and experiments are conducted to show the validity of the proposed controller.

  • PDF

Development of Interferometer for Performance Assessment of IR Optical System (적외선 광학계통 성능평가를 위한 간섭계 개발)

  • 홍경희;고재준;이성태;장세안;오명호
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.179-185
    • /
    • 1991
  • Twyman-Green interferometer is developed for assessment of IR optical system performance. Light source is $CO_2$ gas laser which has 10.6$\mu \textrm m$ wavelength. The light beam is expanded to 2.5 cm dia by Ge lens and splitted by ZnSe parallel plane plate. One of the beams is reflected by refernce mirror which is operated PZT. The fringe will be detected by a pyro-electric vidicon camera and displayed by a CRT monitor. Here, the IR firinge is recorded on the thermal paper. In visible region, the light source is He-Ne laser. The fringe is detected by a CCD camera and displayed by the CRT monitor. The intensity of the fringe is digitized by a image card and processed by a PC. The wavefront aberration function, PSF and OTF are calculated. The results are displayed in 3-D graphs on the monitor or printed out by a line printer.

  • PDF

A Study on the Corona Discharge Simulation Using FEM-FCT Method (FEM-FCT 기법을 이용한 코로나 방전 시뮬레이션에 대한 연구)

  • Min, Ung-Gi;Kim, Hyeong-Seok;Lee, Seok-Hyeon;Han, Song-Yeop
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.3
    • /
    • pp.200-208
    • /
    • 1999
  • In this paper, the corona discharge is analyzed by Finite Element Method(FEM) combined with Flux-corrected Transport(FCT) algorithm. In the previous papers, Finite Difference Method(FDM) combined with FCT was used. Usually in the FDM, the regionof interest is discretized with structured grids. But to refine local regions with same resolution, much more grids are required for the structured grids than for unstructured grids than for unstructured grids. Therefore, we propose the FEM-FCT method to simulate the corona discharge. The proposed method has good flexibility in model shape and can reduce the computational cost by the local refinement where the physical quantities have steep gradients. Using the proposed method, we study the streamer growth of parallel plate electrodes which is initiated by the low and high perturbation density. We find that the varying the initial density of perturbation has very little effect on the streamer propagation. And the corona discharge of the rod-to-plane electrode is simulated. On the surface of the rod electrode, the high concentration of the electric field gives rise to many number of streamer seeds. The strong axial streamer propagate to the plane electrode. The weaker non-axial streamer repel each other and stop growing more. The results are very similar to those of the papers which used the FDM-FCT method on structured grids. Thus we can conclude that the proposed FEM-FCT method is more efficient than the conventional FDM-FCT method by virtue of the reduction in computational grids number.

  • PDF

Displacement pattern of the anterior segment using antero-posterior lingual retractor combined with a palatal plate

  • Seo, Kyung-Won;Kwon, Soon-Yong;Kim, Kyung A;Park, Ki-Ho;Kim, Seong-Hun;Ahn, Hyo-Won;Nelson, Gerald
    • The korean journal of orthodontics
    • /
    • v.45 no.6
    • /
    • pp.289-298
    • /
    • 2015
  • Objective: To evaluate and compare the effects of two appliances on the en masse retraction of the anterior teeth anchored by temporary skeletal anchorage devices (TSADs). Methods: The sample comprised 46 nongrowing hyperdivergent adult patients who planned to undergo upper first premolar extraction using lingual retractors. They were divided into three groups, based on the lingual appliance used: the C-lingual retractor (CLR) group (group 1, n = 16) and two antero-posterior lingual retractor (APLR) groups (n = 30, groups 2 and 3). The APLR group was divided by the posterior tube angulation; posterior tube parallel to the occlusal plane (group 2, n = 15) and distally tipped tube (group 3, n = 15). A retrospective clinical investigation of the skeletal, dental, and soft tissue relationships was performed using lateral cephalometric radiographs obtained pretreatment and post en masse retraction of the anterior teeth. Results: All groups achieved significant incisor and canine retraction. The upper posterior teeth did not drift significantly during the retraction period. The APLR group had less angulation change in the anterior dentition, compared to the CLR group. By changing the tube angulation in the APLR, the intrusive force significantly increased in the distally tipped tube of group 3 patients and remarkably reduced the occlusal plane angle. Conclusions: Compared to the CLR, the APLR provides better anterior torque control and canine tipping while achieving bodily translation. Furthermore, changing the tube angulation will affect the amount of incisor intrusion, even in patients with similar palatal vault depth, without the need for additional TSADs.

Meridional Circulations in a Sliced Cylinder (기울어진 회전 원판에 의한 원통형 용기내의 자오면 유동의 크기에 관한 연구)

  • KIM Jae Won;LIM Hong Sick
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1996.05a
    • /
    • pp.52-57
    • /
    • 1996
  • Mixing is most important for developing an electric washer which transforms angular momentum from rotating solid wall to laundry clothes inside it. For magnification of this mixing effect, some inventions are introduced to washing machine system, i. e., washing plate, washing rod, and even for washing cap in a model of a Korean manufacture. However, the previous efforts show dissatisfaction up till now. In this paper, a triumph to enhance mixing effects to increase washing performance is presented and verified by numerical investigation. The present model to simulate a washing tub is the simple circular cylinder with two endwall disks which is completely filled with a viscous liquid. The present improvement is to change mounting position of a bottom disk of the model cylinder. Therefore, the aim of this work just proposes a new idea, which is numerically inspected, to a producer of washing machine, In detail, this invention is alternating the mounting position of a rotating bottom disk. Actually skewed pulsator is placed in steady of a flat disk, so the two endwall disks at top and bottom are not in parallel. The angle between an inclined bottom disk and the horizontal plane is fixed as 5 degree and physical domain to consider poses a sliced cylinder. Flow fields in both a right circular cylinder and the present improved model are fully depicted by numerical integration on a body fitted nonorthogonal regular uniform grid system. Numerical data to explain flow structure are plotted for understanding of the effects of the inclined disk. Also enhanced mixing effects by the inclined rotating disk are gauged by accurate numerical data used in this work.

  • PDF

Preparation of Nickel Hexacyanoferrate Ion Exchanger for Electrochemical Separation of Cations (양이온의 전기화학적 분리를 위한 페리시안니켈 이온교환체의 제조에 관한 연구)

  • Lee, Ji Hyun;Hwang, Young Gi
    • Applied Chemistry for Engineering
    • /
    • v.21 no.1
    • /
    • pp.52-57
    • /
    • 2010
  • Although chemical sedimentation and ion exchange are usually applied to the treatment of heavy metal ions and radioactive cations, they have some serious disadvantages like a great consumption of chemicals, the disposal of valuable metals, and the secondary pollution of soil by the solid-waste. The advanced countries recently have studied the electrochemical ion exchange, combined electrochemical reduction and ion exchange, for the development of the alternative technique. This study has been performed to investigate the optimum condition for the preparation of the nickel hexacyanoferrate (NiHCNFe) which is an electrochemical ion exchanger. NiHCNFe film was deposited on the surface of nickel plate by chemical method or electrochemical method. The morphology and composition of NiHCNFe were observed by SEM and EDS, respectively. The peak current density of NiHCNFe was measured from the cyclic voltammograms of the continuous oxidation-reduction reaction in a parallel plane ion exchange electrode reactor. It was found that the chemical preparation method was better than the electrochemical method. The concentrated NiHCNFe was apparently deposited on nickel plate when dipping in the preparing solution for 118 h, especially. It also had a best durable performance as an ion exchange electrode.

Basic Investigation for the Won-invasive Measurement of Blood Glucose Concentrations by Millimeter Waves (밀리미터파를 이용한 무혈 혈당 측정에 관한 기초 연구)

  • Kim Dong Kyun;Won Jong Hwa;Potapov Sergey N.;Meriakri Viacheslav V.;Chigryai Evgenii E.
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.1
    • /
    • pp.39-45
    • /
    • 2005
  • As a basic research for the development of a non-invasive blood glucose sensor using millimeter waves, we have presented a method for measuring the dielectric properties of high loss dielectrics, based on the reflection method, and investigated the variation of the dielectric properties of glucose-water and glucose -0.9% NaCl solutions in the 10~90 GHz range. In the proposed method, a minimal reflection condition is formed by placing a specially-chosen low-loss plane-parallel plate in front of a high-loss medium under test at a given frequency range. Using the minimal power reflection coefficient and the corresponding frequency at this condition, tile dielectric properties of the medium can be determined. The measured results on pure water have shown the adequacy of the proposed method. The measured results on glucose-water and glucose -0.9% NaCl solutions in the 10~90 GHz range showed that the variations of the dielectric properties of glucose solutions according to the change of their glucose concentration were maximum in the 30~45 GHz range. From these facts we concluded that the variation of about 3 mole/L in the glucose solutions must be distinguished With the measurement accuracies of ±0.1 dB and ±0.01 GHz.