• 제목/요약/키워드: Parallel AC to DC Converter

검색결과 69건 처리시간 0.024초

HVDC 송전을 위한 전원용 컨버터 시스템의 역률 및 파형개선에 관한 연구 (A Study on Improvement of Powerfactor and Source Waveform Converter System of Power Supply for HVDC Transmission)

  • 황락훈;이춘상;이상용;나승권;조문택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.395-397
    • /
    • 1999
  • This paper presents a method of improving the power factor and the waveform of A.C line currents and the out waveforms of AC to DC fully bridge converter systems which is achieved by connecting converters in series and parallel. The results of simulation show that the power factor and the source voltage and current waveforms are improved by the method of connecting converter in series, and the controlled input voltage and current waveform using a current limit controller.

  • PDF

대용량 연료전지 발전시스템용 전력변환기 개발 (Development of Power Conditioning System for High Power Fuel Cell System)

  • 이진희;백승택;정홍주;강호현;정준모;서인영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.530-532
    • /
    • 2007
  • This paper presents the design, development and performance of a power conditioning system (PCS) for application to a 250kW Molten Carbonate Fuel Cell (MCFC) generation system. A DSP controller was used to control the dc-dc and dc-ac converter operation for grid connection and power injection to the grid. The controller must also supervise the total PCS operation while communicating with the fuel cell system controller. A control method for parallel operation of dc-dc converters was proposed and verified. A 250kW prototype was successfully built and tested. Experimental performances are compared to minimum target requirements of the PCS for MCFC.

  • PDF

전압원 컨버터 기반의 UPFC 모델에 대한 에너지 함수 제어전략의 적용 (Application of energy function control strategy to VSC based UPFC Model)

  • 국경수;오태규;전영환;김학만;김태현;전진홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.259-261
    • /
    • 2000
  • UPFC(Unified Power Flow Controller) consists of two voltage sourced converter(VSC)s inserted into AC system through series and parallel coupling transformer, where two VSCs are linked by capacitor at DC-side. Since VSC acts as an AC voltage source behind a reactance, where both magnitude and phase angle of the source are controllable, UPFC can be represented by the equation related to input-output relation of two VSCs. Voltage control of DC-link capacitor provides the path of real power flow between two VSCs. While UPFC is controlled for maintaining the given reference value in steady state, it should be controlled for damping power oscillation in dynamics. For such a control objective, the control strategy based on the energy function was proposed and has been shown to be effect and robust for damping power oscillation of power system. In this paper, UPFC model based on the VSC was analysed and applied to power-flow control and stability analysis. The control strategy based on the energy function is adopted for damping power oscillation of power system. The effectiveness of proposed control strategy was verified by simulation study

  • PDF

풍력발전의 전력저장을 위한 충전회로 (A Charging Circuit for the Power Stotage of Wind Power Generation)

  • 고석철;강형곤;임성훈;한병성;송승호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권11호
    • /
    • pp.635-644
    • /
    • 2002
  • Many generating units can be in parallel connection to one battery and inverter. However, one of the biggest problems we encountered is that wind speed is fluctuated sharply in accordance with the unstable weather conditions. To solve this problem, we need energy storage equipment such as storage lead-acid battery. We design a system and analyze its modeling so that it supplies a stable power to the load through DC-AC inverter part. In this paper, we applied dual step-up/down buck-boost converter and dual high-frequency half-bridge converter to the proposed system. These converters are used to store energy in the battery regardless of the change of the wind speed. The operation process of two proposed types of converters for high-power battery charging is discussed along with simulation and experimental result. We design a charging circuit which is applicable in the actual wind power generation system for 30kw and confirm the circuit's validity.

A Resonant Characteristics Analysis and Suppression Strategy for Multiple Parallel Grid-connected Inverters with LCL Filter

  • Sun, Jian-jun;Hu, Wei;Zhou, Hui;Jiang, Yi-ming;Zha, Xiao-ming
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1483-1493
    • /
    • 2016
  • Multiple parallel inverters have multiple resonant frequencies that are influenced by many factors. This often results in stability and power quality problems. This paper develops a multiple input multiple output model of grid-connected inverter systems using a closed-loop transfer function. The influence factors of the resonant characteristics are analyzed with the developed model. The analysis results show that the resonant frequency is closely related to the number, type and composition ratio of the parallel inverters. To suppress resonance, a scheme based on virtual impedance is presented, where the virtual impedance is emulated in the vicinity of the resonance frequency. The proposed scheme needs one inverter with virtual impedance control, which reduces the design complexity of the other inverter controllers. Simulation and experimental tests are carried out on two single phase converter-based setups. The results validate the correctness of the model, the analytical results and the resonant suppressing scheme.

Multiple Buck-Chopper using Partial Resonant Switching

  • Mun Sang-Pil;Suh Ki-Young;Lee Hyun-Woo;Chun Jung-Ham
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.189-192
    • /
    • 2001
  • This paper proposed that an AC-DC converter system using multiple buck-chopper operates with four choppers connecting to a number of parallel circuits. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative results on computer are included to confirm the validity of the analytical results. The partial resonant circuit makes use of an inductor using step-down and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in a partial resonant circuit makes charging energy regenerated at input power source for resonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

고압 나트륨 램프 구동용 전력변환장치의 역률 개선 (Power Factor improvement of Power Conversion Equipment for High Pressure Sodium Lamps)

  • 이상현;서기영;이현우;이수흠;문상필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.147-150
    • /
    • 2002
  • HPSL(High Pressure Sodium lamp)have attracted much attention in recent years, because they offer high luminous efficiency and very long life. Recently, AC-DC converters have been widely as power factor improvement circuits in the power conversion equipment An application of the ZVT-PWM(Zero Voltage Transition Pulse Width Modulation) boost converter, which has great advantage on miniaturization and high power density, to the power factor improvement circuit of the HPSL inverter are described to identify the power factor correction characteristics of the inverter. In this paper the series-parallel resonant inverter(electronic ballast) for driving a HPS lamp is discussed. Finally, a power factor corrector is cascaded in front of the electronic ballast. Consequently, a high power factor above 0.99 and low THD on the line current can be achieved.

  • PDF

Soft-Switching T-Type Multilevel Inverter

  • Chen, Tianyu;Narimani, Mehdi
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1182-1192
    • /
    • 2019
  • In order to improve the conversion efficiency and mitigate the EMI problem of conventional hard-switching inverters, a new soft-switching DC-AC inverter with a compact structure and a low modulation complexity is proposed in this paper. In the proposed structure, resonant inductors are connected in series for the arm branches, and resonant capacitors are connected in parallel for the neutral point branches. With the help of resonant components, the proposed structure achieves zero-current switching on the arm branches and zero-voltage switching on the neutral point branches. When compared with state-of-art soft-switching topologies, the proposed topology does not need auxiliary switches. Moreover, the commutation algorithm to realize soft-switching can be easily implemented. In this paper, the principle of the resonant operation of the proposed soft-switching converter is presented and its performance is verified through simulation studies. The feasibility of the proposed inverter is evaluated experimentally with a 2.4-kW prototype.

출력 리플 저감을 위한 LED 드라이버의 주회로 방식 특성 비교 (Comparison of Main Circuit Type Characteristics of LED Driver for Output Ripple Reduction)

  • 박대수;김태경;오성철
    • 한국산학기술학회논문지
    • /
    • 제20권3호
    • /
    • pp.491-499
    • /
    • 2019
  • 최근에, 전원 공급 장치에 있어서 파워의 품질에 대한 요구가 높아지고 있다. IEC 61000-3-2 규격은 조명을 위한 AC/DC 전원 공급 장치에 대하여 역률(PF)과 전체 파형 왜곡률(THD)에 대한 규격을 만족하도록 요구하고 있다. 또 출력단의 전류 변화에 의해 발광체 광량이 바뀜에 따라 발생되는 플리커 현상에 대해 유럽권 선진국가는 ripple rate의 기준을 15~30%로 설정해 규제하고 있다. 따라서 국내에서도 기준을 마련하고 규제를 추진 중에 있다. 그래서 본 논문은 PFC 규격을 만족하고, 회로 1차, 2차 간 절연 기능을 가지기 위해 Flyback 컨버터를 적용하며, LED 전류의 저주파 리플을 저감하기 위해 Flyback, Coupled Inductor, LC 병렬 공진 필터, LLC 공진 필터, Cuk을 이용한 각각의 LED 구동회로를 PSIM을 통해 시뮬레이션 함으로써 각각의 방식들을 비교하였으며, 출력측 리플 저감을 위해 1차측에 Coupled Inductor와 2차측에 LC 공진을 적용한 Coupled LC 공진 회로를 제안하였으며, Coupled LC 공진 방식은 출력 커패시터가 78uF으로 작으며, 출력 리플은 전압 2.38V, 전류 0.05A로 기존의 방식보다 22%의 출력 리플 저감을 확인 하였다.