• 제목/요약/키워드: Panorama radiography

검색결과 21건 처리시간 0.024초

구강방사선 실습내용에 관한 분석 (Analysis of oral radiography practice)

  • 안금선;김효정
    • 한국치위생학회지
    • /
    • 제11권5호
    • /
    • pp.783-790
    • /
    • 2011
  • Objectives : The purpose of this study was to examine students' difficulties in the process of oral radiography practice, to raise awareness of the importance and necessity of oral radiography and decipher, and to provide some information on effective ways of oral radiography practice. Methods : The subjects in this study were 285 dental hygiene students at K college, who included 153 sophomores and 132 graduates-to-be from June to November, 2010. Results : 1. The parts of the anatomy structure that they found it most difficult to decipher were maxillary molar(25.3%) and lower molar(22.1%). 2. They made during oral radiography was an improper film positioning(35.1%). 3. The part of bisecting technique was adjusting vertical and horizontal angles(53.0%). 4. The part of paralleling technique was positioning XCP in the oral cavity(44.2%). 5. The part of bite-wing technique was adjusting vertical and horizontal angles(38.2%). 6. The part of occlusion technique was positioning film and tube head(36.5%). 7. The part of panorama technique was finding out program setting(42.5%). Conclusions : The findings of the study indicated that in terms of anatomy structure decipher, it's especially difficult to decipher maxillary molar and lower molar, and that film positioning was difficult to do in the process of oral radiography. What difficulties they faced in applying each kind of oral radiography techniques and which part of the oral cavity they found it hard to radiograph were analyzed as well in this study. Given the findings of the study, more intensive practice is required to help students to acquire accurate oral radiography techniques to ensure their successful job performance in the future.

파노라마 방사선사진과 구내 방사선사진에서 골조직 정량평가의 비교연구 (A comparative study of the quantitative assessment on the panoramic and intraoral radiographs)

  • 김재덕
    • Imaging Science in Dentistry
    • /
    • 제31권3호
    • /
    • pp.129-133
    • /
    • 2001
  • Purpose: To compare the copper equivalent values measured at premolar and molar areas in the copper equivalent images of panoramic and intraoral radiographs and to evaluate the possibility of the copper equivalent images of panorama for the assessment the bone density. Materials and Methods : Intraoral radiograms at mandibular premolar and molar area and panoramas of 6 human dry skulls were taken with copper-step wedge by Heliodent MD (Siemens Co., Germany) and by Planmeca (PM 2002 CC, Planmeca, Helsinki, Finland) were used for experiment. The copper equivalent values measured at premolar and molar areas in the copper equivalent im ages of panorama and intraoral film were compared. Results: The copper equivalent values were ranged 0.20 mmCu-0.44 mmCu at the molar areas, 0.05 mmCu-0.31 mmCu at the premolar areas on panoramic images. There were no significant differences (p>0.5) between the copper equivalent values on intraoral images and those on panoramic images measured at premolar areas and molar areas respectively. The correlation coefficient between the copper equivalent values on intraoral images and those on panoramic images was respectively 0.8495 at molar areas and 0.6184 at premolar areas. Conclusions : The copper equivalent images of panorama for the assessment the bone density appeared to be significant at molar area compared with the one of intraoral radiograph.

  • PDF

치과방사선검사에서 방사선방어용구 사용 전, 후의 유효선량에 대한 평가 (Evaluation of effective dose in panorama, cone beam CT and the usefulness of x-ray protective)

  • 김재인;최원근;이소라;이정화;이관섭
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.15-22
    • /
    • 2012
  • The purpose of this study was to measure the absorbed dose and calculate the effective dose for cone beam computed tomography (CBCT) and panorama units and to estimate usefulness of x-ray protective. Rando phantom and glass dosimeters were used for dosimetry. The absorbed doses were measured at 15 organs and 14 remainder from correspond to ICRP 2007 recommendations. The absorbed dose was highest in salivary glands as measured CBCT 2.420mGy, panorama 0.307mGy. Absorbed dose in another organs were high in order of thyroid, brain, skin, esophagus. The effective dose was CBCT 0.100mSv, panorama 0.011mSv and effective dose of panorama was higher than that of CBCT by 10 times. In case of wearing x-ray protective, reducing effective dose of CBCT by 0.066mSv (66%) and panorama by 0.008mSv (72%). Effective dose were reduced by radiological shielding but it needs further optimization studies, where dosimetric data are analyzed in combination with image quality with keep the patients' exposure as low as possible.

  • PDF

Development of a new ball-type phantom for evaluation of the image layer of panoramic radiography

  • Yeom, Han-Gyeol;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제48권4호
    • /
    • pp.255-259
    • /
    • 2018
  • Purpose: This study proposes a new ball-type phantom for evaluation of the image layer of panoramic radiography. Materials and Methods: The arch shape of an acrylic resin phantom was derived from average data on the lower dental arch in Korean adult males. Metal balls with a 2-mm diameter were placed along the center line of the phantom at a 4-mm mesiodistal interval. Additional metal balls were placed along the 22 arch-shaped lines that ran parallel to the center line at 2-mm buccolingual intervals. The height of each ball in the horizontal plane was spaced by 2.5 mm, and consequently, the balls appeared oblique when viewed from the side. The resulting phantom was named the Panorama phantom. The distortion rate of the balls in the acquired image was measured by automatically calculating the difference between the vertical and horizontal length using $MATLAB^{(R)}$. Image layer boundaries were obtained by applying various distortion rate thresholds. Results: Most areas containing metal balls (91.5%) were included in the image layer with a 50% distortion rate threshold. When a 5% distortion rate threshold was applied, the image layer was formed with a small buccolingual width along the arch-shaped center line. However, it was medially located in the temporomandibular joint region. Conclusion: The Panorama phantom could be used to evaluate the image layer of panoramic radiography, including all mesiodistal areas with large buccolingual width.

파노라마촬영장치의 협설선형단층상에 의한 상악동과 치조골 평가 (An assessment of maxillary sinus and alveolar bone in cross-sectional linear tomogram of panorama)

  • 김재덕
    • Imaging Science in Dentistry
    • /
    • 제33권3호
    • /
    • pp.137-141
    • /
    • 2003
  • Purpose: To evaluate the precision of measurements taken of dental implants in bucco-lingually sectioned views of the maxilla by linear tomograms of the panorama and to assess the visibility of the inferior wall of the maxillary sinus. Materials and Methods : Eighty sites prepared with implants of gutta percha cone in the sockets of the upper premolars and molars of 10 dry skulls were radiographically examined using linear tomograms of panorama, and scanned coronally and axially by computed tomography. The differences in mm between the measurements in bucco-lingually sectioned images of maxillary alveolar bone and the true length and width of the implanted gutta percha cones were compared as mean values (mean) and standard deviations (SD) for each radiographic technique. Linear tomography of panorama was compared with computed tomography for visualization of the relationship between the inferior wall of maxillary sinus and the end of each implant. Results: The deviations between the actual implant length and the measured values taken from the linear tomograms (0.44±0.39 mm) was significantly less than the measured values from the multiplanar reconstructed images of the axially scanned computed tomogram (1.21 ± 0.90 mm). There was statistically significant difference (p < 0.05) between two techniques in the differences between the measurements and true implant length. The relationship of the inferior border of maxillary sinus with end of implant was worse identified with the linear tomogram of panorama (68%) than the multiplanar reconstructed image of axially scanned computed tomogram (99%). Conclusion: We could not find any differences in the accuracy of length measurement between the linear tomogram of panorama and computed tomogram, but computed tomogram allowed for a better visualization of the inferior wall of the maxillary sinus than the linear tomogram.

  • PDF

치과방사선 검사 시 방사선작업종사자의 위치에 따른 방사선 노출 평가 (Radiation Exposure Evaluation Depending on Radiation Workers' Locations during Dental Radiography)

  • 정천수;김지영
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.433-438
    • /
    • 2015
  • 치과방사선 검사에 있어 방사선작업종사자의 위치에 따라 방사선 노출 정도를 평가하고자 촬영실과 납유리, 조작대에서 방사선량률을 측정하였다. 사용된 장치로는 Standard(Max-GLS, Shinhung), 파노라마(PCH-2500, Vatech), 세팔로(PCH-2500), Cone beam CT(PHT-30LFO, Vatech)이며, 방사선측정기는 PM1405 장비이다. 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 그 결과 촬영실 안에서는 Cone beam CT가 98 uSv/h로 가장 높았으며, standard가 0.4 uSv/h로 가장 낮은 수치를 보였다. 또 파노라마가 촬영방식이 다름으로 인하여 세팔로 보다 높게 측정되었다. 납유리 표면과 조작대에서는 구강내와 파노라마, 세팔로는 모두 기록준위 이하로 측정되었지만, Cone beam CT는 누설선량이 있는 것으로 측정되었다. 이에 방사선작업종사는 적절한 방호도구를 하고 촬영시간을 최대한 줄여야 한다. 또, 방사선실의 구조 또한 효율적으로 설계해야 할 것이다. 치과방사선검사는 최근 지속적으로 증가하고 있기 때문에 환자와 방사선작업종사자에 대한 적절한 방호 대책이 필요하다.

파노라마방사선사진에서 골형태 계측과 구내표준필름에서 구리당량치의 상관관계 (The correlationship between mandibular radiomorphometric indices in panorama and bone mineral density in Cu-equivalent image of intraoral film)

  • 김재덕
    • Imaging Science in Dentistry
    • /
    • 제33권3호
    • /
    • pp.131-135
    • /
    • 2003
  • Purpose: To determine whether the mandibular radiomorphometric indices in panoramic radiography are correlated with the bone mineral density of Cu-equivalent images in intraoral film. Materials and Methods: The bone mineral density (BMD) of the mandibular premolar area was measured in the Cu-equivalent image of intraoral film. The Panoramic Mandibular Index (PMI) and Mandibular Cortical Width (MCW) were measured in panoramic radiographs of six dry mandibles, and the Pearson correlation between PMI, MCW, and BMD were tested. Results: There were no significant correlations between PMI and BMD (r = 0.280), nor between MCW and BMD (r =0.237). Conclusion: The results show that PMI and MCW were poor diagnostic indicators of mandibular BMD in the six dry mandibles used in this study. The correlationship between the mandibular radiomorphometric indices (PMI and MCW) and mandibular BMD needs to be researched further using large in vivo patient samples.

  • PDF

Bone Density Relationship of Mandible and Cervical Vertebrae in Panoramic Radiography

  • Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • 제30권4호
    • /
    • pp.259-263
    • /
    • 2000
  • Purpose: Upper cervical vertebrae are commonly imaged together with the jaw bones in panoramic radiography. There have been many studies investigating the possible role of mandible as an indicator of osteoporosis. But the result doesn't show unanimity. This study measured bone densities of mandible and second and third cervical vertebrae to find out any relationship between these two areas. These results may contribute in panorama being used as a screening method in detecting possible osteoporotic patient. Materials and Methods: Randomly selected 226 digitized panoramic images with cervical vertebrae shadows from 156 dental patients between 5 to 80 years of age were used. And the bone densities of second and third cervical vertebrae, apical areas of first and second mandibular molars and interdental areas were measured. The bone density measurements were restricted to the cancellous bone and the average and standard deviations and paired t-tests were done to each measurements. Results: All the measurements were statistically significantly related. The best relationship was found between the third cervical vertebrae and first and second mandibular apical areas. The average and standard deviations of the measured bone density ratios of these areas were 1.20±0.45 and 1.34±0.48 each. Conclusion: Patients whose panoramic bone density of the third cervical vertebrae are much below those of mandibular first or second molar apical areas may have osteoporosis.

  • PDF

측두하악관절의 panoramic double TMJ 방사선사진상에서 하악과두와 인접구조의 관계 (Relationship between the condyle and adjacent structures in double temporomandibular joint view using panorama)

  • 이창율;김재덕
    • Imaging Science in Dentistry
    • /
    • 제31권4호
    • /
    • pp.209-214
    • /
    • 2001
  • Purpose: To investigate the ability of double TMJ view by multifunctional panorama to view the bony components and the space of the temporomandibular joint. Materials and Methods: Ten dry skulls fitted with resin shims over the articular surface of the condyle were used to reproduce the temporomandibular joint space. Fine metal wires were attached to the three portions of contours of the condylar head and the articular eminence. With 10 dry skulls and 20 cases having TMJ dysfunction, double TMJ views by multifunctional panorama (Planmeca 2002 Proline CC) and transcranial views were taken, analyzed from the anatomical view point, and compared statistically in view of the widths of the posterior joint space and the condylar head. Results: In double TMJ view, the supero-anterior part of the condyle represented the lateral 1/3, the most superior part represented center portion, and the posterior part medial l/3 of the condyle. In maximum mouth opening, no other structures were superimposed with the condyle in double TMJ view. In double TMJ view, petrous bone was moderately superimposed with the superior part of the condyle and the posterior increment of angle exposure made wider the images of the articular eminence and the condyle. The tendency of reduction in the posterior joint space appeared in the side of TMJ dysfunction compared with the normal side. The posterior joint spaces in double TMJ view were statistically wider (p<0.05) than those in transcranial view. The correlation coefficient was 0.5179 between the widths of the posterior joint spaces in two radiographic views. Conclusions: Double TMJ view can be substituted for transcranial view in evaluating the TMJ dysfunction.

  • PDF

정상 및 골다공증 여성의 파노라마 방사선사진 계측치 비교 (Comparison of panorama radiomorphometric indices of the mandible in normal and osteoporotic women)

  • 김주연;나경수;정연화
    • Imaging Science in Dentistry
    • /
    • 제34권2호
    • /
    • pp.69-74
    • /
    • 2004
  • Purpose : This study was conducted to compare the radiomorphometric indices of the mandible on panoramic radiographs among three groups of normal, osteopenia and osteoporosis and to determine whether panoramic indices have validity in predicting osteoporotic risk. Materials and Methods: Ninty-four postmenupausal women aged 42-72 years (mean 62±7.5) were examined using dual energy X-ray absorptionmetry (DEXA) of the lumbar and classified into three groups by WHO classification. Panoramic mandibular index (PMI), mandibular cortical thickness (Mental index (MI), Antegonial index (AI), Gonial index (G!)) and the mandibular cortical index (MCI) were measured bilaterally on panoramic radiographs and analyzed. Results: There were signigicant differences among normal, osteopenic and osteoporoti groups in PMI (I), PMI (S), MI, AI, GI and MCI. The sensitivities of the MCI (93%) and the combination index of MCI and MI (90%) in diagnosing osteopenic/osteoporotic cases were high. Conclusion: The widths and shapes of the mandibular cortical bone on panoramic radiography may highly reflect the systemic osteopenic/osteoporotic conditions of the patients.

  • PDF