• 제목/요약/키워드: Panel heater

검색결과 41건 처리시간 0.022초

적외선 패널히터의 온도분포 측정 (Measurement of Temperature Distribution in the Infrared Panel Heater)

  • 이공훈;하수석;김욱중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1178-1183
    • /
    • 2004
  • Temperature distribution and heating characteristic of the panel heater for infrared heating have been investigated. The temperature variation with time is firstly measured with the thermocouple to figure out the response time of the heater to the power input. The heater reaches faster to the steady state in comparison to the ceramic heater. The infrared thermal imaging system is utilized to investigate the temperature distribution over the heater surface. The measured thermal images show that the thermal boundary layer induced by the free convection near the heater surface affects the temperature distribution on the surface. The images also show the fairly good uniformity of the temperature distribution in the core region of the surface.

  • PDF

유동해석을 통한 신형 탈황설비용 GGH 요소 최적화 (Optimization of the Gas Gas Heater Element for Desulfurization Equipment through Flow Analysis)

  • 류봉조;오부진;백수곤;김후식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.599-602
    • /
    • 2008
  • This paper deals with the optimization of Gas-Gas-Heater elements for desulfurization equipment through flow analysis. The flow analysis model used in the paper is ${\kappa}-{\varepsilon}$ turbulent flow model. Temperature and flow velocity distributions for three types of panel elements are calculated. Through the analysis the following conclusions are obtained. Firstly, pressure differences of between inlet and outlet for three types of panel elements do not exceed in the standard pressure difference. Secondly, it is expected that NU-type panel element having wide area of heat transfer will be more effective in the aspect of the heat transfer.

  • PDF

냉장고 진공단열재 성능진단을 위한 열유속계 위치에 관한 연구 (A Study on the Heat Flux Meter Location for the Performance Test of a Refrigerator Vacuum Insulation Panel)

  • 하지수
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.471-476
    • /
    • 2013
  • The present study has been carried out to elucidate the optimal method for the performance test of a refrigerator vacuum insulation panel (VIP), by using numerical heat transfer analysis. Three locations of heat flux meter have been tested, for deriving the best test method to clarify the normal or the abnormal condition of the vacuum insulation panel in a refrigerator. The first location of the heat flux sensor is at the same place as the heater, the second one is at the nearby side location of the heater and the third one is at the opposite side location of heater in the refrigerator. The heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$ were calculated for the cases with the normal VIP, and with the abnormal VIP, and their differences analyzed. From the present study, the first and the second method had a mere difference characteristics of heat flux and $1/q^{{\prime}{\prime}^2}$ or $q^{{\prime}{\prime}^4}$, between the cases with the normal or the abnormal VIP. The magnitude of the heat flux after 300sec had a great difference between the cases with the normal or abnormal VIP for the third method, and it could be considered the most optimal method to test the performance of a refrigerator vacuum insulation panel.

침적 입자를 고려한 유동해석을 통한 신형 탈황설비용 GGH 요소 최적화 (Optimization of the Gas-Gas Heater Element for Desulfurization Equipment through Fluid Analysis of considering Deposition Particles)

  • 오부진;류봉조;이영신;김종호;백수곤
    • 한국소음진동공학회논문집
    • /
    • 제20권7호
    • /
    • pp.611-619
    • /
    • 2010
  • The paper deals with the proper design of GGH(gas-gas heater) panel elements of desulfurization equipments in a thermoelectric power plant. When fossil fuels such as coal, petroleum et cetera are burnt to ashes, sulfur oxide compounds are produced, and calcareous sludges are deposited at GGH panel elements. In this case, operation of a power plant equipments is interrupted, and a tremendous economic loss comes into existence. One of the purposes of the paper is to find flow velocity distributions and regions of depositions when calcareous sludges pile up on the GGH panel elements through the fluid analysis. In the fluid analysis, flow velocity and position distributions of particles between GGH panel elements are demonstrated according to time variation for ammonia and calcium hydroxide particles.

OLED 증착을 위한 선형증발원 히터 위치선정 (Selection of Heater Location in Linear Source for OLED Vapor Deposition)

  • 주영철;한충환;엄태준;이상욱;김국원;권계시
    • 제어로봇시스템학회논문지
    • /
    • 제14권6호
    • /
    • pp.515-518
    • /
    • 2008
  • Organic light emitting diode(OLED) is one of the most promising type of future flat panel display. A linear source is used to deposite organic vapor to a large size OLED substrate. An electric heater which is attached on the side of linear source heats the organic powder for the sublimation. The nozzle of heater, which is attached at the top of the linear source has an optimal temperature. An numerical analysis has been performed to find optimal heater position for the optimal nozzle temperature. A commercial CFD program, FLUENT, is used on the analysis. Two-dimensional and three-dimensional analysis have been performed. The analysis showed that the heater should be attached at the outer side of crucible wall rather than inner side of housing, which was original design. Eighteen milimeter from the top of the linear source was suggested as the optimal position of heater. Improving thermal performance of linear source not only helps the uniformity of organic vapor deposition on the substrate but also increase productibity of vapor deposition process.

OLED 증착용 서큘러소스의 열적성능 해석 (Thermal Performance Analysis of Circular Source for OLED Vapor Deposition)

  • 주영철;한충환;엄태준;이상욱;김국원
    • 반도체디스플레이기술학회지
    • /
    • 제6권4호
    • /
    • pp.39-42
    • /
    • 2007
  • Temperature distribution of the circular heat source was studied by analyzing the heat transfer of the environment of the circular source for OLED. Circular nozzle source was used to fabricate thin organic layer as the organic material in it was heated, vaporized and deposited to the large size panel. A modified heater structure of circular source has been suggested. The results of numerical analysis shows that the modified heater structure can use 15% more powder in a batch than the original heater structure does. Moreover, the modified heater structure can improve the uniformity of organic vapor deposition by controlling the temperature.

  • PDF

FPD 장비 습식공정에서의 안전한 히터 공급 계통도 및 제어 회로 (Safety Schematic Diagram and Sequence of Heater in FPD Wet Equipment)

  • 유흥렬;손영득
    • 전기전자학회논문지
    • /
    • 제23권1호
    • /
    • pp.107-111
    • /
    • 2019
  • FPD(Flat Panel Display) WET(습식) 장비의 히터 사용은 필수로 사용된다. 히터 사용에 따른 단선과 과열로 인한 전기사고가 다발하여 안전적인 전기 계통도 및 인터락이 필요하다. 따라서 본 논문에서는 FPD WET장비에 들어가는 전기 계통도 및 인터락을 제안하였다. 레벨센서, 과열방지기, SSR heater sink와 같은 하드웨어 인터락을 넣었으며, 전기 계통도로써는 ELB-MC-SSR-EOCR-Heater로 구성되어 있다. 인터락 발생시 마그네틱 컨텍터(MC)가 오프되어 Heater의 전원을 차단하는 방식이다. 전기적 과전류 보호장치인 EOCR 과전류, 부족전류, 단선 체크를 하면서 히터에 이상 있을 시 MC를 차단하는 인터락이 구성되어 있다. 이러한 회로 구성 및 인터락은 WET 장비 뿐만 아니라 히터가 들어가는 어떠한 장비에도 유용할 것으로 보인다.

태양열 이용 난방용 공기가열기 개발을 위한 기초 운전 특성 (Basic Operational Characteristics for Developments of Solar Air Heater for Air Heating in Winter)

  • 김종열;홍부표;우종수;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.87-94
    • /
    • 2011
  • To develop the solar air heater, prototype of solar heater with test room set up on the roof of test chamber and operation characteristics were examined with solar radiation. Air induced from outside was supplied by a blower and also heated air was supplied to the test chamber(size of 1,000mm(inwidth)*2,000mm(in length)*2,000mm(in depth)) established already for performance. It was clear that almost 30% of solar radiation was converted into effective heating energy at maximum and the highest air temperature was $46^{\circ}C$, and thus solar air heater in winter could be used as an possible alternative heating system in building. Furthermore, heat energy obtained from solar air heater can be applied to regenerate absorber in the solar desiccant cooling system.

$RADCAD^{TM}$를 이용한 PDP용 Pane 1 가열 시스템 해석 (Analysis of Heating System for PDP Panel Using $RADCAD^{TM}$)

  • 김욱중;홍용주;박영선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.453-458
    • /
    • 2001
  • Analysis of radiation heating system for producing 60" size PDP panels was carried out using $RADCAD^{TM}$ software. Optimum arrangement of infrared heating elements was found to obtain uniform temperature distribution in PDP panel during heating. Heating capacity of each heater was determined to obtain an appropriate maximum panel temperature. Parametric study to find the effect of design parameters such as the thermophysical and optical properties of glass and cooling system was carried out. As a reference system, about 35 kW heating capacity was chosen to obtain about 800 K maximum panel temperature after 30 minute heating. The maximum temperature difference in panel was below 20 K. The maximum/minimum and its difference in the panel were very sensitive to the variation of the emissivity of glass and cooling block.

  • PDF

Si 칩에 형성된 박막히터를 이용한 Chip-on-Glass 공정 (Chip-on-Glass Process Using the Thin Film Heater Fabricated on Si Chip)

  • 정부양;오태성
    • 마이크로전자및패키징학회지
    • /
    • 제14권3호
    • /
    • pp.57-64
    • /
    • 2007
  • Si 칩에 박막히터를 형성하고 이에 전류를 인가하여 LCD (liquid crystal display) 패널의 유리기판은 가열하지 않으면서 Si 칩만을 선택적으로 가열함으로써 Si 칩을 LCD 패널의 유리기판에 실장 하는 새로운 COG 공정기술을 연구하였다. $5\;mm{\times}5\;mm$ 크기의 Si 칩에 마그네트론 스퍼터링법으로 폭 $150\;{\mu}m$,두께 $0.8\;{\mu}m$, 전체 길이 12.15 mm의 정방형 Cu 박막히터를 형성하였으며, 이에 0.9A의 전류를 60초 동안 인가하여 Si칩의 Sn-3.5Ag 솔더범프를 리플로우 시킴으로써 Si 칩을 유리기판에 COG 본딩하는 것이 가능하였다.

  • PDF