• Title/Summary/Keyword: Paired T-Test

Search Result 2,809, Processing Time 0.03 seconds

Wound Healing Effects of Rose Placenta in a Mouse Model of Full-Thickness Wounds

  • Kim, Yang Woo;Baek, Seung Ryeol;Lee, Eun Sook;Lee, Sang Ho;Moh, Sang Hyun;Kim, Soo Yun;Moh, Ji Hong;Kondo, Chieko;Cheon, Young Woo
    • Archives of Plastic Surgery
    • /
    • v.42 no.6
    • /
    • pp.686-694
    • /
    • 2015
  • Background Rosa damascena, a type of herb, has been used for wound healing in Eastern folk medicine. The goal of this study was to evaluate the effectiveness of rose placenta from R. damascena in a full-thickness wound model in mice. Methods Sixty six-week-old C57BL/6N mice were used. Full-thickness wounds were made with an 8-mm diameter punch. Two wounds were made on each side of the back, and wounds were assigned randomly to the control and experimental groups. Rose placenta ($250{\mu}g$) was injected in the experimental group, and normal saline was injected in the control group. Wound sizes were measured with digital photography, and specimens were harvested. Immunohistochemical staining was performed to assess the expression of epidermal growth factor (EGF), vascular endothelial growth factor (VEGF), transforming growth factor-${\beta}1$ (TGF-${\beta}1$), and CD31. Vessel density was measured. Quantitative analysis using an enzyme-linked immunosorbent assay (ELISA) for EGF was performed. All evaluations were performed on postoperative days 0, 2, 4, 7, and 10. Statistical analyses were performed using the paired t-test. Results On days 4, 7, and 10, the wounds treated with rose placenta were significantly smaller. On day 2, VEGF and EGF expression increased in the experimental group. On days 7 and 10, TGF-${\beta}1$ expression decreased in the experimental group. On day 10, vessel density increased in the experimental group. The increase in EGF on day 2 was confirmed with ELISA. Conclusions Rose placenta was found to be associated with improved wound healing in a mouse full-thickness wound model via increased EGF release. Rose placenta may potentially be a novel drug candidate for enhancing wound healing.

The Wound Healing Effects of Opuntia Ficus-indica in Dogs (개에서 손바닥 선인장의 피부 결손창 치료 효과)

  • Lee Hyun sung;Cheong Jongtae;Park Hyun jung;Shin Tae-kyun;Kim Jae hoon;Lee Joo myoung
    • Journal of Veterinary Clinics
    • /
    • v.22 no.1
    • /
    • pp.43-49
    • /
    • 2005
  • The aim of this study is to investigate the wound healing effects of the Opuntia ficus-indica. Four full-thickness skin wounds(2.5 cm × 2.5 cm) were made in different areas on the back in each of five dogs. Two wounds were used for wound size measurement and two for skin biopsy. The ten full-thickness wounds were treated with the extract of Opuntia ficus-indica, and the ten full-thickness wounds were treated with normal saline. The wound areas were measured every other day for three weeks after wounding. Statistical analysis was performed with the paired t-test. The wound healing rates were 32.9±4.0%, 28.2±7.1%, 42.2±4.1%, 55.0±4.3%, 76.6±2.8%, 86.8±2.3%, 94.0±1.l%, 97.3±0.8%, 99.3±0.3%, 99.8±0.2%, 100.0±0.0% in the experimental group, and 18.0± 8.2%, 13.S± 11.6%, 15.2±6.1 %, 36.9±8.8%, 62.4±4.1%, 80.0±2.3%, 86.0±1.4%, 94.0±0.9%, 96.9±0.8%, 97.8±0.3%, 99.7±0.1% in the control group on the 1/sup st/, 3/sup rd/, 5/sup th/, 7/sup th/, 9/sup th/, 11/sup th/, 13/sup th/, 15/sup th/, 17/sup th/, 19/sup th/, 21/sup st/ day. On the 17/sup th/ day, the wound closed above 99.9% in 1 dog of the experimental group. On the 19/sup th/ day, the wound closed above 99.9% in 3 dogs of the experimental group. On the 21/sup st/ day, the wound closed above 99.9% in 5 dogs of the experimental group, and 1 dog of the control group. The wound healing period was shortened by 2 to 4 days in the experimental group as compared with the control group. The tensile strength was 4,508±513 g/㎠ in the experimental group and 2,772±400 g/㎠ in the control group on the 21/sup st/ day after wounding. The tensile strength was significantly higher in the experimental group than in the control group(p< 0.05). Inflammation rapidly spread and disappeared in the experimental group but not in the control group. Fibroblast and vascularization were found on the 5/sup th/ day in both group and increased only in the experimental group on the 9/sup th/ day. The firs finding of epithelialization was on the 13/sup th/ day in the experimental group and the 21/sup st/ day in the control group. A significantly higher wound healing rate(p< 0.05), tensile strength(p< 0.05) and better histopathological findings were observed in the experimental group than in the control group throughout the experimental period. These results suggest that topical application of Opuntia ficus-indica extract can promote wound healing in dogs.

The Comparative Analysis of the Present and Expected Level on Meal-Price and Facilities Investment Cost Perceived by Foodservice Managers of Contract-Managed Highschools in Seoul (서울시내 고등학교 위탁급식의 급식비와 투자비의 실태 및 위탁업체의 기대수준 비교 분석)

  • Bae, Hwan-Mee;Kim, Hyun-Ah;Shin, Seo-Young;Jo, Mi-Na;Park, Su-Yeon;Cha, Jin-A;Yi, Bo-Sook;Yang, Il-Sun
    • Journal of the Korean Society of Food Culture
    • /
    • v.17 no.5
    • /
    • pp.578-583
    • /
    • 2002
  • The purposes of this study were to a) find out the operational characteristics of the contract-managed highschool foodservice in Seoul, b) investigate the expected level of meal-price and facilities investment cost perceived by contract-managed highschool foodservice managers c) compare the present level and expected level of meal-price and facilities investment cost. From October 12 to November 13 in 2001, the questionnaires were mailed to 249 high schools which was managed by contract foodservice company with respondent rate 40.2%. Data were analyzed using SPSS Win(10.0) for descriptive analysis and one group paired t-test. The results of this study were as follows ; 1. The student enrollment of highschools run by contract-managed foodservice was 1,243 with 72.6% participation rate of school lunch program. The average meal-price was 2,138 won. The average annual period of school foodservice operation was 156.78 days per year. The average contracting period was about 3 years. 2. The average cost concerned in the facilities investment amounts 169,578,180 won at the initial investment and 25,204,092 won at the repairs and maintenance cost in the course of operation. 3. The present level of meal-price and facilities investment cost were respectively 2,136won/meal and 171,157,336.72 won. And expected level of meal-price and amount of facilities investment cost were 2,418.75 won and 121,353,215.19 won. Comparing the present level with the expected level of the meal- price and facilities investment cost, expected level of meal-price was significantly higher than the present level of meal-price(p<.001) and expected level of facilities investment cost was significantly lower than present level of facilities investment cost(p<.001).

Comparison of TEMPO BC and MYP Plate Methods for the Enumeration of Bacillus cereus in Various Foods

  • Lee, Da Yeon;Kim, Hee Yeon;Cho, Yong Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.4
    • /
    • pp.249-253
    • /
    • 2017
  • This study aimed to compare the automated most-probable-number (MPN) TEMPO BC and the quantitative mannitol-egg yolk-polymyxin (MYP) plate methods for enumeration of Bacillus cereus in food samples known to be frequently contaminated. Food products that were naturally or artificially contaminated with B. cereus were analyzed by both methods. A difference of less than 1 log (CFU/g) between the two methods was noted in 95.3% samples. There were no significant differences in artificially contaminated products between the two methods in terms of $R^2$ values for sauce products, jorim products, fish products, etc. However, a significant difference was noted for sunsik, fermented soybean products, and products. The linear equation of naturally versus artificially contaminated food was $log_{(TEMPO\;BC)}=0.8453{\times}log_{(MYP\;plate\;agar)}+0.1642$. Statistical analysis of the results showed good agreement between the two methods. Due to growing interest in food safety, the use of the TEMPO BC method may increase. In response to this trend, the results from this study will offer valuable comparative data on the feasibility of existing methods and help develop new approaches for food safety testing.

Knowledge and attitude change towards radiation protection after radiation safety management education in dental hygiene students (치위생과 학생들의 학업관련 특성에 따른 방사선안전관리 교육 후 방사선 방어에 대한 지식과 태도의 변화)

  • Kim, Sung-Ae;Lee, Ji-Young;Hwang, Se-Hyun;Cho, Mi-Suk;Park, Jung-Hyun;Jung, Nam-Yeong;Yu, Byeng-Chul
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.101-109
    • /
    • 2015
  • Objectives: The purpose of the study is to investigate the knowledge and attitude towards radiation protection after radiation safety management education in dental hygiene students. Methods: After receiving informed consents, a self-reported questionnaire was carried out for 135 dental hygiene students in Busan on June 17 for preliminary survey and September 3 for post-education survey, 2011. The questionnaire was modified from Han and consisted of 5 questions of general characteristics, 6 questions of radiation use, 7 questions of scholastic characteristics, 15 questions of knowledge towards radiation safety management, and 15 questions of attitude towards radiation safety management. Cronbach's alpha was 0.808 in the knowledge towards radiation safety management. Attitude towards radiation safety management included 15 questions of general attitude towards radiation safety management, individual and patient, and attitude toward radiation exposure reduction measured by Likert 5 scale. Cronbach's alpha was 0.970 in the attitude towards radiation safety management. Data were analyzed using SAS version 9.2 for educational analysis, technical analysis and multivariate analysis, paired t-test, and GLM. Results: Significant differences were shown in the knowledge and attitudes towards radiation safety management; the level of knowledge was respectively $9.8{\pm}3.0$ and $12.9{\pm}1.9$ points before and after education, and the level of attitude was $4.28{\pm}0.51$ and $4.53{\pm}0.47$ before and after the education. The levels of knowledge and attitude according to general characteristics showed a significant differences in grade and academic results. Post-education survey suggested that the education is very important and necessary and can change the knowledge and attitude towards radiation safety management in the dental hygiene students. Conclusions: Through the radiation safety management education, the levels of knowledge and attitude towards radiation safety management have changed significantly, which showed that the radiation safety management education proved to be very effective. Therefore, an effective radiation safety management education program is necessary to improve the levels of knowledge and attitude towards radiation safety management in the dental hygiene students.

RADIOLOGICAL EVALUATION OF FRACTURE LINE STABILITY DURING FUNCTIONAL LOADING AFTER MINIPLATE FIXATION OF MANDIBULAR ANGLE FRACTURES (하악 우각부 골절의 소형금속판 내고정 후 기능시 골접합선의 안정도에 관한 방사선학적 평가)

  • Suh, Chang-Ho;Bae, Jung-Soo;Chin, Byung-Rho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.428-434
    • /
    • 2001
  • After miniplate fixation of mandibular angle fractures, fracture line stability during functional loading was evaluated. Using panoramic radiographs, 15 mandibular angle fracture patients who were treated by open reduction and one miniplate fixation along the external oblique ridge, were evaluated at postoperative 1, 4 and 8 weeks. At each time, 2 radiographs were taken: one taken during maximum biting of hardened silicone sheet on the affected side molar area and the other on the non-affected side. The distraction gap of inferior border of mandible at each time and each side was measured and these data were analysed statistically with clinical findings. The differences of inferior border distraction gap during hardened silicone sheet biting on the affected side molar area and on the non-affected side molar area at 4 week radiographs were smaller than those of 1 week's except one case. At 8 week's radiographs, the fracture lines were so stabilized that it was almost impossible to find the gap differences except one case and there were increased radiopacity along the entire fracture lines. Clinically, bony union was confirmed in all cases during plate removal performed at postoperative 6 month. By statistical analysis(paired t-test), the inferior border distraction gap during biting of hardened silicone sheet on the affected side was significantly reduced during 1 and 4 week interval(p<0.01). The differences of inferior border distraction gap during biting on the affected side molar area and on the non-affected side molar area were also significantly reduced at 1 and 4 week interval(p<0.01). But the inferior border distraction(compression) gap during non-affected side biting was not significantly changed. From these findings, it could be concluded that fracture line stability during functional loading after one miniplate fixation of mandibular angle fractures stems mainly from reduction of inferior border distraction gap during affected side biting on time interval. According to these radiographic and clinical findings, the clinical superiority of one miniplate fixation technique in mandibular angle fracture treatment could be confirmed.

  • PDF

Accuracy of simulation surgery of Le Fort I osteotomy using optoelectronic tracking navigation system (광학추적항법장치를 이용한 르포씨 제1형 골절단 가상 수술의 정확성에 대한 연구)

  • Bu, Yeon-Ji;Kim, Soung-Min;Kim, Ji-Youn;Park, Jung-Min;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.2
    • /
    • pp.114-121
    • /
    • 2011
  • Introduction: The aim of this study was to demonstrate that the simulation surgery on rapid prototype (RP) model, which is based on the 3-dimensional computed tomography (3D CT) data taken before surgery, has the same accuracy as traditional orthograthic surgery with an intermediate splint, using an optoelectronic tracking navigation system. Materials and Methods: Simulation surgery with the same treatment plan as the Le Fort I osteotomy on the patient was done on a RP model based on the 3D CT data of 12 patients who had undergone a Le Fort I osteotomy in the department of oral and maxillofacial surgery, Seoul National University Dental Hospital. The 12 distances between 4 points on the skull, such as both infraorbital foramen and both supraorbital foramen, and 3 points on maxilla, such as the contact point of both maxillary central incisors and mesiobuccal cuspal tip of both maxillary first molars, were tracked using an optoelectronic tracking navigation system. The distances before surgery were compared to evaluate the accuracy of the RP model and the distance changes of 3D CT image after surgery were compared with those of the RP model after simulation surgery. Results: A paired t-test revealed a significant difference between the distances in the 3D CT image and RP model before surgery.(P<0.0001) On the other hand, Pearson's correlation coefficient, 0.995, revealed a significant positive correlation between the distances.(P<0.0001) There was a significant difference between the change in the distance of the 3D CT image and RP model in before and after surgery.(P<0.05) The Pearson's correlation coefficient was 0.13844, indicating positive correlation.(P<0.1) Conclusion: Theses results suggest that the simulation surgery of a Le Fort I osteotomy using an optoelectronic tracking navigation system I s relatively accurate in comparing the pre-, and post-operative 3D CT data. Furthermore, the application of an optoelectronic tracking navigation system may be a predictable and efficient method in Le Fort I orthognathic surgery.

Evaluation of the clinical efficacy of a TW3-based fully automated bone age assessment system using deep neural networks

  • Shin, Nan-Young;Lee, Byoung-Dai;Kang, Ju-Hee;Kim, Hye-Rin;Oh, Dong Hyo;Lee, Byung Il;Kim, Sung Hyun;Lee, Mu Sook;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.237-243
    • /
    • 2020
  • Purpose: The aim of this study was to evaluate the clinical efficacy of a Tanner-Whitehouse 3 (TW3)-based fully automated bone age assessment system on hand-wrist radiographs of Korean children and adolescents. Materials and Methods: Hand-wrist radiographs of 80 subjects (40 boys and 40 girls, 7-15 years of age) were collected. The clinical efficacy was evaluated by comparing the bone ages that were determined using the system with those from the reference standard produced by 2 oral and maxillofacial radiologists. Comparisons were conducted using the paired t-test and simple regression analysis. Results: The bone ages estimated with this bone age assessment system were not significantly different from those obtained with the reference standard (P>0.05) and satisfied the equivalence criterion of 0.6 years within the 95% confidence interval (-0.07 to 0.22), demonstrating excellent performance of the system. Similarly, in the comparisons of gender subgroups, no significant difference in bone age between the values produced by the system and the reference standard was observed (P>0.05 for both boys and girls). The determination coefficients obtained via regression analysis were 0.962, 0.945, and 0.952 for boys, girls, and overall, respectively (P=0.000); hence, the radiologist-determined bone ages and the system-determined bone ages were strongly correlated. Conclusion: This TW3-based system can be effectively used for bone age assessment based on hand-wrist radiographs of Korean children and adolescents.

Effect of Occlusal Stabilization Appliance on Driving Distance in Golf (교합안정장치가 전문골프선수들의 드라이버 비거리에 미치는 영향)

  • Kwon, Tae-Hoon;Shin, Sang-Wan;Ryu, Jae-Jun;Lee, Richard Sung-Bok;Ahn, Su-Jin;Choi, Yeo-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.157-168
    • /
    • 2010
  • Many athletes have been using occlusal stabilization appliances to improve their performance. Few studies have examined the benefits of such an appliance in golf. We determined the effect of such appliances on the masticatory muscle activities and driving distances of professional golf players. The appliances were customized for each player and adjusted using a computerized device. The electromyographic muscle activities and driving distances with and without the appliance were measured and compared using the K7 Analyzer and the GolfAchiever II assembly. A paired t-test was used for statistical analysis. The muscle activities of the temporo-frontal and masseter muscles with the appliance were significantly more stable than those without the appliance, and the driving distances with the appliance were significantly different from those without it. Although there were intra-individual differences, professional golf players with temporomandibular disorders showed a greater improvement in performance.

Effect of Increase in Occlusal Vertical Dimension on Appendage Muscle Strength (수직적 교합고경의 증가가 사지 근력에 미치는 영향에 관한 연구)

  • Ahn, Su-Jin;Lee, Richard Sung-Bok;Lee, Suk-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.169-178
    • /
    • 2010
  • Objective. This study was conducted to observe the effect on appendage muscle strength according to increase in occlusal vertical dimension. Materials and methods. Ten males with a mean age of 21 were selected. The tested occlusal splints were made at the position of increased occlusal vertical dimension of 2mm,3.5mm and 5mm from the intercuspal position. Before and after wearing occlusal splints, the appendage muscle strength were tested by Cybex II dynamometer (Lumex Inc., Ronkonkoma, NY, USA). Results. Statistical analysis using the paired t-test revealed significant differences for flexion and extension of the hip, pronation of the forearm, internal rotation of the shoulder, external and internal rotation of the knee, and dorsiflexion and plantarflexion of the ankle (p<0.05). Conclusions. As the result of this study, we conclude that when occlusal vertical dimension was increased, most of mean muscular strength values were increased. Especially at the position of 3.5mm increased vertical dimension displayed the highest mean muscular strength value than other positions.