• Title/Summary/Keyword: Pahang

Search Result 44, Processing Time 0.022 seconds

Development of multi-dimensional body image scale for malaysian female adolescents

  • Chin, Yit Siew;Taib, Mohd Nasir Mohd;Shariff, Zalilah Mohd;Khor, Geok Lin
    • Nutrition Research and Practice
    • /
    • v.2 no.2
    • /
    • pp.85-92
    • /
    • 2008
  • The present study was conducted to develop a Multi-dimensional Body Image Scale for Malaysian female adolescents. Data were collected among 328 female adolescents from a secondary school in Kuantan district, state of Pahang, Malaysia by using a self-administered questionnaire and anthropometric measurements. The self-administered questionnaire comprised multiple measures of body image, Eating Attitude Test (EAT-26; Gamer & Garfinkel, 1979) and Rosenberg Self-esteem Inventory (Rosenberg, 1965). The 152 items from selected multiple measures of body image were examined through factor analysis and for internal consistency. Correlations between Multi-dimensional Body Image Scale and body mass index (BMI), risk of eating disorders and self-esteem were assessed for construct validity. A seven factor model of a 62-item Multi-dimensional Body Image Scale for Malaysian female adolescents with construct validity and good internal consistency was developed. The scale encompasses 1) preoccupation with thinness and dieting behavior, 2) appearance and body satisfaction, 3) body importance, 4) muscle increasing behavior, 5) extreme dieting behavior, 6) appearance importance, and 7) perception of size and shape dimensions. Besides, a multidimensional body image composite score was proposed to screen negative body image risk in female adolescents. The result found body image was correlated with BMI, risk of eating disorders and self-esteem in female adolescents. In short, the present study supports a multi-dimensional concept for body image and provides a new insight into its multi-dimensionality in Malaysian female adolescents with preliminary validity and reliability of the scale. The Multi-dimensional Body Image Scale can be used to identify female adolescents who are potentially at risk of developing body image disturbance through future intervention programs.

Physical and Mechanical Properties of Light Red Meranti Treated with Boron Preservatives

  • Man Djun LEE;Ridge Wei Cheong TANG;Zeno MICHAEL;Miqdad KHAIRULMAINI;Azmi ROSLAN;Ahmad Faidzal KHODORI;Hazim SHARUDIN;Pui San LEE
    • Journal of the Korean Wood Science and Technology
    • /
    • v.52 no.2
    • /
    • pp.157-174
    • /
    • 2024
  • This study investigates the influence of varying concentrations of boric acid (BA) preservative on the physical and mechanical properties of light red meranti (LRM) found in Sarawak. LRM or Shorea leprosula samples were treated with various concentrations of BA via the dip diffusion method using American Society for Testing and Materials (ASTM) standards. The physical property, particularly the retention rate and mechanical properties, bending strength, modulus of elasticity (MOE), tensile and compression strength parallel to grain of impregnated and control samples were tested to determine the effects of BA preservative. The retention rate was found to increase with increasing BA concentration and higher surface area to volume ratio. The mechanical properties in terms of the MOE and tensile strength parallel to grain were found to be greater than those of the control samples, whereas the bending strength and tensile strength parallel to grain were lower. Amongst the results, only the retention rate and MOE showed significant interaction effects at 5% level of significance between all factors tested (samples size and BA concentration for retention rate and BA concentration for MOE).

Stratigraphical Study on Tertiary System of Pohang Area Compared with Petrogeologies of Japan (포항(浦項)의 제삼기층(第三紀層)과 일본유전지질(日本油田地質)의 층위대비연구(層位對比硏究))

  • Chang, Seyong
    • Economic and Environmental Geology
    • /
    • v.9 no.1
    • /
    • pp.1-11
    • /
    • 1976
  • It is believed that geological survey, drilling and geophysical survey which was carried out on Tertiary deposits in Pohang is a valuable but through the studying of many Tertiary sediments in Japan discovered many questions on analysis of final report prepared by National geological survey. The main reason is: 1. The seismic sound velocity which have regulated in the final report prepared by geological survey for Tertiary deposits in Pohang was 1,500-2,000m/sec in spite of oil bearing sediments of same age in Japan are 2,000-3,800m/sec. These may means the requirement of reconsideration of seismic velocity for Tertiary deposits in Pohang and required to have a dipper drilling. 2. Stratigraphically, geophysically, and paleontologically, the Tertiary deposits in Pahang land area is similar with that of Nishiyama-Hunakawa formations of Akita oil field in Japan. Nishiyama-Hunakawa formation is the main oil bearing formation in Japan. 3. Those valcanic rock including andestitic rock and liparitic rock which have extensively distributed over either at land area or at sea bottom, assumed by geological survey as the base of Tertiary sediments. But in case of Japan many oil bearing deposits are in over laid by these kind of volcanic rock. Therefore a possible of same condition with Japan is presumable on Tertiary sediments in Pohang. 4. It is believed that the Tertiary sediments of land area in Pohang is the extension of offshore basin but is wandering that the final report submitted by geologic survey have not remain any word on report of ECAFE discribed so much problematics as followed: A. Although it was assumed that no great thickness exceeding 1,000 meters, or major structures would be encountered in the Tertiary offshore sequence, it was hoped that shallow hydrocarbon deposits might be found, because these sediment are lithologically similar to those of the same age in the producing area of the northwest Honshu region of Japan where hydrocarbon are extracted from depths of only 500 to 600 meters. B. Four possible hydrocarbon trap conditions are represented in the survey area: anticlinal folds, faults, pinch outs, along the igneous basement and lateral facies changes. C. Most of the prime possible reservoir area are beyond the 50 meter water depth mark, except for the structures in Yonil Bay. D. Despite the shallowness of the offshore basin, sufficient trap condition exist in the area to warrant further exploration for hydrocarbon. 5. All of the problems mentioned above have gave us a strong reasons to have us hesitating to make a final conclusion on Tertiary problems in Pohang, before to have a drill to a depth to 3,000 meters or more whatever it is the Tertiary or a Mesozoics below 1,000 meters.

  • PDF

Experimental Investigation on Post-Fire Performances of Fly Ash Concrete Filled Hollow Steel Column

  • Nurizaty, Z.;Mariyana, A.A.K;Shek, P.N.;Najmi, A.M. Mohd;Adebayo, Mujedu K.;Sif, Mohamed Tohami M.A;Putra Jaya, Ramadhansyah
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.335-344
    • /
    • 2021
  • In structural engineering practice, understanding the performance of composite columns under extreme loading conditions such as high-rise bulding, long span and heavy loads is essential to accuratly predicting of material responses under severe loads such as fires or earthquakes. Hitherto, the combined effect of partial axial loads and subsequent elevated temperatures on the performance of hollow steel column filled fly ash concrete have not been widely investigated. Comprehensive test was carried out to investigate the effect of elevated temperatures on partial axially loaded square hollow steel column filled fly ash concrete as reported in this paper. Four batches of hollow steel column filled fly ash concrete ( 30 percent replacement of fly ash), (HySC) and normal concrete (CFHS) were subjected to four different load levels, nf of 20%, 30%, 40% and 50% based on ultimate column strength. Subsequently, all batches of the partially damage composite columns were exposed to transient elevated temperature up to 250℃, 450℃ and 650℃ for one hour. The overall stress - strain relationship for both types of composited columns with different concrete fillers were presented for each different partial load levels and elevated temperature exposure. Results show that CFHS column has better performance than HySC at ambient temperature with 1.03 relative difference. However, the residual ultimate compressive strength of HySC subjected to partial axial load and elevated temperature exposure present an improvement compared to CFHS column with percentage difference in range 1.9% to 18.3%. Most of HySC and CFHS column specimens failed due to local buckling at the top and middle section of the column caused by concrete crushing. The columns failed due to global buckling after prolong compression load. After the compression load was lengthened, the columns were found to fail due to global buckling except for HySC02.