• 제목/요약/키워드: PZT-Actuator

검색결과 359건 처리시간 0.029초

PZT 구동기를 이용한 지렁이 이동방식의 캡슐형 내시경용 마이크로 로봇 (An Earthworm-Like Locomotive Mechanism for Capsule Endoscopes Using PZT Actuator)

  • 지창열;박석호;윤석진;김병규;박장현
    • 대한기계학회논문집A
    • /
    • 제30권1호
    • /
    • pp.84-89
    • /
    • 2006
  • A wireless capsule endoscope has been developed to replace the conventional endoscope. However, the commercialized capsule endoscope moves passively by peristaltic waves, which has some limitations for doctors to diagnose more thoroughly and actively. In order to solve this problem, a locomotive mechanism is proposed for wireless capsule endoscopes. Based on the tests of various actuators, a piezo actuator is selected as a micro actuator for capsule endoscope. In general, piezo actuators are known to have limited displacement with high voltage supply. In order to overcome the limitation of common piezo actuator, the impact based piezo actuator, is developed to realize long stroke up 11mm. By using the impact based piezo actuator, a prototype of an earthworm-like locomotive mechanism was developed. In addition, the proposed locomotive mechanism has engraved clamps mimicked the claw of an insect. The earthworm-like locomotive mechanism has 15 mm in diameter and 30mm under retraction stage and 41 mm under elongation stage in total length. Hollow space is allocated to comprise essential endoscope components such as a camera, a communication module, bio sensors, and a battery. For the feasibility test of proposed locomotive mechanism, a series of experiments were carried out including in-vitro tests. Based on results of the experiments, we conclude that the proposed locomotive mechanism is effective to be used for micro capsule endoscopes.

수평방향 변위증폭을 위해 U-형상의 PZT 스트립과 지렛대 구조를 이용한 압전구동형 엑츄에이터의 설계, 제작 및 실험

  • 서영호;이택민;이준형;최두선;황경현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 춘계학술대회 논문요약집
    • /
    • pp.130-130
    • /
    • 2004
  • 본 논문에서는 RF 스위치의 엑추에이터로 사용하기 위한 수평구동형 박막형 PZT 엑추에이터의 설계, 제작 및 시험에 관한 것이다 기존의 RF 스위치들은 대부분 수직 방향의 접촉 방식을 채택하고 있고, 대부분 구조체가 두껍지 않은 막으로 이루어져 있어서, 엑추에이터로부터 힘을 충분히 전달받지 못한다. 이로 인해, 접촉력이 상대적으로 작게 되어, 접촉저항을 줄이기 위한 접촉압력을 내기 위해 접촉 면적을 줄일 수밖에 없게 된다. 따라서, 본 연구에서는 효과적인 힘의 전달이 가능한 수평방향의 접촉 방식과 상대적으로 큰 힘을 낼 수 있는 PZT 엑추에이터를 사용하고자 한다.(중략)

  • PDF

세라믹칩 전기적 성능검사 시스템을 위한 고속구동 액튜에이터 개발 (Development of a High speed Actuator for electric performance testing System of ceramic chips)

  • 배진호;김성관
    • 한국산학기술학회논문지
    • /
    • 제12권4호
    • /
    • pp.1509-1514
    • /
    • 2011
  • IT 제품의 핵심 전자부품에는 MLCC, chip inductors, chip Varistors 등이 있다. chip의 전기적 특성을 검사하기 위해 리노핀을 이용한 접촉검사 방식이 사용되고 있다. 리노핀을 이용한 칩 검사에 고속으로 구동할 수 있는 Actuator가 필요하다. 그 중 PZT Actuator는 압전소자를 이용한 마이크로 Actuator의 하나로 높은 분해능 및 좋은 응답성 그리고 큰 힘을 낼 수 있는 장점을 가지고 있다. 하지만 진동변위가 매우 작다는 단점이 있다. 그래서 이러한 단점을 극복하기 위하여 변위 증폭구조를 설계하는 연구가 활발히 진행되고 있다. 따라서 본 논문에서는 유연힌지를 이용한 지레구조 증폭기구를 설계하였으며, 반도체칩 검사장비 산업분야에서 성능검사 및 전기적 특성을 측정할 수 있는 리노핀용 고속구동 Actuator 시스템을 개발하였다.

압전 감지기/작동기를 포함하는 셀 요소의 개발 (Development of Shell Element to Analyze an Intelligent Structure with Piezoelectric Sensor/Actuator)

  • 황우석;고성현;박현철
    • 한국소음진동공학회논문집
    • /
    • 제13권3호
    • /
    • pp.225-231
    • /
    • 2003
  • A new three-dimensional thin shell element for a structure containing an integrated distributed piezoelectric sensor and actuator is Proposed. The assumed strain formulation and the bubble function are introduced to improve the performance of the shell element. A finite element formulation gives a general tool that can predict the static or dynamic responses of the shell with piezoelectric sensor/actuator. The verification through the calculation of the static response for the piezoelectric bimorph beam shows that the results agree with those from the theoretical analysis very well. Dynamic response of a shell shows that the reduction of vibration is possible with the introduction of the piezoelectric shell sensor and actuator. However. the curvature of sensor/actuator is an obstacle for application, since the flexible PVDF is not strong enough and the PZT with curvature should be made specially.

주파수응답 분리방법을 이용한 비접촉식 AFM (Non-contact type AFM using frequency separation scheme)

  • 이성규;염우섭;박기환;송기봉;김준호;김은경;박강호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.375-378
    • /
    • 2002
  • In this paper, the frequency response separation scheme is proposed for high scanning speed and simple structure of non-contact type of AFM. A self-sensing cantilever is attached on the actuator for detect the atomic force between tip and the media surface. VCM or PZT are used for actuator. This paper presents the method to simplify the actuator structure and the performance of each actuator for non-contact type AFM. Based on the frequency response separation scheme, the only one actuator plays roles 1311owing low frequency surface and modulating self-sensing cantilever tip in contrast with convention non-contact type AFM. 10 ${\mu}{\textrm}{m}$ standard grid sample imaged to verify proposed scheme. This result shows the possibility simplifying the actuator structure and reducing cost of non-contact type AFM.

  • PDF

층수 변화에 따른 적층형 압전액츄에이터의 압전특성 (Piezoelectric properties of multilayer actuator as a function of the number of multilayer)

  • 이갑수;이일하;류주현;정영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.270-271
    • /
    • 2007
  • In this study, piezoelectric properties of PZW-PMN-PZT multilayer actuator sintered at $900^{\circ}C$ low temperature have been investigated. The multilayer actuator was fabricated by tape casting methods. The density above $8[g/cm^3]$ was obtained at all the specimens. Also, according to increasing the number of multilayer, effective electromechanical coupling factor$(k_{eff})$ showed increasing trend. The $k_{eff}$ of multilayer actuator showed the maximum value of 0.283 at 11 layer. However, according to increasing the number of multilayer, mechanical quality factor(Qm') showed decreasing tend. The Qm' of multilayer actuator showed the maximum value of 920 at 5 layer.

  • PDF

Analysis of a three-dimensional FEM model of a thin piezoelectric actuator embedded in an infinite host structure

  • Zeng, Xiaohu;Yue, Zhufeng;Zhao, Bin;Wen, S.F.
    • Advances in materials Research
    • /
    • 제3권1호
    • /
    • pp.237-257
    • /
    • 2014
  • In this paper, we adopted a two-dimensional analytical electro-elastic model to predict the stress distributions of the piezoelectric actuator in 3D case. The actuator was embedded in an elastic host structure under electrical loadings. The problem is reduced to the solution of singular integral equations of the first kind. The interfacial stresses and the axial normal stress in both plane stress state and plane strain state were obtained to study the actuation effects being transferred from the actuator to the host. The stress distributions of the PZT actuator in different length and different thickness were analyzed to guarantee the generality. The validity of the present model has been demonstrated by application of specific examples and comparisons with the corresponding results obtained from the Finite Element Method.

마이크로 펀칭시스템 구현을 위한 심벌변위확대기구의 설계 (Design of Cymbal Displacement Amplification Device for Micro Punching System)

  • 최종필;이광호;이해진;이낙규;김성욱;주은덕;김병희
    • 한국공작기계학회논문집
    • /
    • 제18권1호
    • /
    • pp.36-41
    • /
    • 2009
  • This paper presents the development of a micro punching system with modified cymbal mechanism. To realize the micro punching, we introduced the hybrid system with a macro moving part and micro punching part. The macro moving part consists of a ball screw, a linear guide and the micro step motor and micro punching part includes the PZT actuators and displacement amplification device with modified cymbal mechanism. The PZT actuator is capable of producing very large force, but they provide only limited displacements which are several micro meters. Thus the displacement amplification device is necessary to make those actuators more efficient and useful. For this purpose, a cymbal mechanism in series is proposed. The finite element method was used to design the cymbal mechanism and to analyze the mode shape of the one. The displacement and mode shape error between the FEM results and experiments are within 10%. A considerable design effort has been focused on optimizing the flexure hinge to increase the output displacement and punching force.

압전구동기를 이용한 정밀 가공용 초음파 진동장치 해석 및 실험 (Analysis and Experiment of Ultrasonic Vibration Mechanism using PZT Actuator for Precision Laser Machining)

  • 김우진;전용호;조성학
    • 한국정밀공학회지
    • /
    • 제28권12호
    • /
    • pp.1347-1352
    • /
    • 2011
  • Recently, as the aged population grows around the world, many medical instruments, devices, and their fabrication processes are developing. Among the devices, a drug delivery stent is a good example for precision machining. Conventional drug delivery stent has problem of the remaining polymer because the drug is coated on the surface with it. If the drug is impregnated into the micro hole array on the stent surface, the polymer can be perfectly eliminated. Micro sized holes are generally fabricated by laser machining however, the fabricated holes do not have an enough aspect ratio to contain the drug or a good surface finish to deliver the stend to blood vessel tissue. To overcome these problems, we propose a vibration-assisted machining mechanism with PZT (Piezoelectric Transducers) for abrication of micro sized holes better. The results indicated that the burr size can be significantly decreased with vibration assisted in nanosecond pulse laser drilling test.

압전구동기를 이용한 정밀 가공용 초음파 진동장치 설계 (Design of Ultrasonic Vibration Device using PZT Actuator for Precision Laser Machining)

  • 김우진;;조성학;박종권;이문구
    • 한국레이저가공학회지
    • /
    • 제14권2호
    • /
    • pp.8-12
    • /
    • 2011
  • As the aged population grows around the world, many medical instruments and devices have been developed recently. Among the devices, a drug delivery stent is a medical device which requires precision machining. Conventional drug delivery stent has problems of residual polymer and decoating because the drug is coated on the surface of stent with the polymer. If the drug is impregnated in micro hole array on the surface of the stent, the problem can be solved. Micro sized holes are generally fabricated by laser machining; however, the fabricated holes do not have an enough aspect ratio to contain the drug or a good surface finish to deliver it to blood vessel tissue. To overcome these problems, we propose a vibration-assisted machining mechanism with PZT (Piezoelectric Transducers) for the fabrication of micro sized holes. If the mechanism vibrates the eyepiece of the laser machining head, the laser spot on the workpiece will vibrate vertically because objective lens in the eyepiece shakes by the mechanism's vibration. According to the former researches, the vibrating frequency over 20kHz and amplitude over 500nm are preferable. The vibration mechanism has cylindrical guide, hollowed PZT and supports. In the cylinder, the eyepiece is mounted. The cylindrical guide has upper and low plates and side wall. The shape of plates and side wall are designed to have high resonating frequency and large amplitude of motion. The PZT also is selected to have high actuating force and high speed of motion. The support has symmetrical and rigid characteristics.

  • PDF