• Title/Summary/Keyword: PWM filter

Search Result 310, Processing Time 0.03 seconds

Output Filter Design of High Precision Current Source Magnet Power Supply (고안정 전류원 전자석 전원장치의 출력 필터 설계)

  • Choi, Won-Shik;Kim, Min-Jae;Jeong, Il-Woo;Park, Ki-Hyeon;Park, Hyun-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.992-993
    • /
    • 2015
  • 본 논문은 양방향 전류 제어를 위한 고안정 전류원 전원 장치의 영점 전류 부근에서의 PWM 방법과 출력 필터 설계를 위한 가이드 라인에 대해 기술 하였다. LCR 출력 필터의 공진점에서 전압의 크기를 줄이기 위한 댐핑 저항의 크기에 따라 Bode plot을 통해 임피던스와 전달함수의 주파수 특성을 분석하고 낮은 Q-factor를 갖는 출력 필터의 댐핑 저항 크기를 확인 하였다.

  • PDF

A SERIES ACTIVE POWER FILTER ADOPTING CONTROL APPROACH OF DETECTING LOAD VOLTAGE

  • Yao Weizheng;Wang Qun;Liu Jinjun;Wang Zhaoan
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.785-789
    • /
    • 1998
  • In this paper a new control approach of detecting load voltage is proposed. It can directly detect the as side harmonic voltage of a voltage source load for the series APE to do dynamic compensation for harmonic voltages. In addition, the control methods of PWM inverter and its dc side voltage are discussed. According to these, a prototype of the series APF is manufactured and corresponding experiment studies are done.

  • PDF

Design of Digital Controller for Uninterruptible Power Supply Using Disturbance Observer

  • Cho, Jun-Seok;Lee, Seung-Yo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.830-835
    • /
    • 1998
  • This paper describes a new digital control method of 3-phase PWM inverter with LC filter for uninterruptible power supply(UPS). The overall control system is based on the dead beat control, which has the minor loop of current control within the voltage control major loop. In this paper, the full-order disturbance observer is proposed to compensate the disturbances generated due to a sudden change of load currents. The proposed disturbance observer is composed of dead beat observer which estimates state values within a finite time, and cancels the disturbances by adding feedforward compensation loop in the control system. In addition, on order to remove a defect of oscillation generated in output of conventional dead beat controller, a modified dead beat algorithm is proposed in this paper.

  • PDF

A Operation characteristics of the HB inverter for Remote Plasma Source (리모트 프라즈마 전원용 하프 브리지 인버터의 운전 특성)

  • Kim S.S.;Won C.Y.;Choi D.K.;Choi S.D.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.611-615
    • /
    • 2003
  • In this paper, a operation characteristics and analysis of the HB(half bridge) inverter for remote plasma system are studied. the remote plasma system is cleaning system for the chemical vapor deposition (CVD) chamber in semiconductor processing. The remote plasma system is powered by the RF generator The main power stage of the RF generator is used for the HB PWM inverter with an low pass filter in the secondary circuit of the transformer. The detailed mode analysis of HB invertor was described. The operation characteristics of Remote Plasma Source are verified by simulation and experimental results.

  • PDF

Noise Modeling and Improved Harmonic Spectrum for DC/DC Converter by RPWM Control

  • Park, Seok-Ha;Kim, Jong-Bum;Kim, Jin-Sung;Kim, Yang-Mo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.620-624
    • /
    • 1998
  • Higher operating frequency provides rising output power from modern power electronics devices. Nevertheless, the switch-mode operation results in EMI which is produced due to large di/dt and/or dv/dt. The methods to reduce EMI are the use of classic and expensive input filters or the addition of the active filter into the main circuits. In this paper, by using the randomized PWM the EMI effect can be reduced and implementation of the proposed control scheme into the forward converter can improve the harmonic spectrum as well

  • PDF

A Sinusoidal Input Current Multi-Level Converter Using Transformer (변압기를 사용한 정현파 입력전류 Multi-Level Converter)

  • Kim, C.S.;Lee, H.W.;Suh, K.Y.;Chun, J.H.;Han, H.D.;Park, W.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.250-253
    • /
    • 2001
  • This paper is proposed a sinusoidal input voltage Multi-level AC-DC Converter using transformer. In this paper Multi-level PWM Control converter which controls input current by combining buck Converters together to improve input current characteristic, and confirmed its validity throughout simulation and experiment. This method, which is multiplying and duplicating output of converter of equal capacity, is able to control unit power factor of input current, reduce the problem caused by high frequency switching, and apply to high power converter because filter is not necessary.

  • PDF

Comparison of Flywheel Systems for Harmonic Compensation Based on Wound/Squirrel-Cage Rotor Type Induction Motors

  • Kim, Yoon-Ho;Jeong, Yeon-Suk;Jeong, Yeon-Suk
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.127-132
    • /
    • 2001
  • This paper describes two different systems which can compensate harmonic currents generated in a power system. As non-linear loads increase gradually in industry fields, harmonic current generated in the electric power network system also increases. Harmonic current makes a power network current distorted and generates heat, vibration and noise in the power machinery. Many approaches have been applied to compensate harmonic currents generated in the power system. Among various approaches, in this paper, two kinds are compared and evaluated. They are flywheel compensators bases on secondary excitation of WRIM(wounded rotor induction motor) and SCIM(squirrel cage induction motor). Both systems have a common structure. They use a flywheel as an energy storage device and use PWM inverters. The main differences are the size and rating of the converter used.

  • PDF

Dynamics of Current-Mode-Controlled DC-to-DC Converters With Input Filter Stage (입력 필터단이 연결된 전류 제어 DC-DC 변환기의 동특성)

  • Kim, Dong-Soo;Lee, Dong-Gyu;Cho, Byung-Cho
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.269-271
    • /
    • 2005
  • 본 논문은 입력 필터 상호 작용 (Interacton)의 일반적인 해석 방법으로 입력 필터단이 연결된 전류 제어 DC-DC 변환기의 동특성을 해석한다. 또한 입력 필터단의 강한 영향을 받는 상태의 전류 제어 강압형 변환기의 새로운 소신호 해석 결과를 제시한다. 이론적 해석은 컴퓨터 시뮬레이션 결과 및 제작된 실험용 PWM DC-DC 변환기로 검증하였다.

  • PDF

The Control of Single Phase AC/DC Converter by using Binary Combination (바이너리 조합에 의한 단상 AC/DC 컨버터의 제어)

  • Park, S.W.;Chun, J.H.;Woo, J.I.;Kim, J.H.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1336-1338
    • /
    • 2000
  • This paper proposed the single phase multi-level PWM AC/DC converter using binary combine which controls input current by combining buck converters to improve input current characteristic, and confirmed its validity throughout simulation and experiment. This method, which is multiplying and duplicating output of converter of equal capacity, has the advantage of being able to control unit power factor of input current and reducing of the problem caused by high frequency switching, and appling to high power converter because filter is not necessary etc.

  • PDF

Receving-end's power factor improvement and harmonic current filtering useing the private-substion STATCOM (자가변전설비용 STATCOM의 수전단 역률개선과 고조파 전류 필터링)

  • Oh, Young-Woong;Lee, Eun-Woong;Lim, Su-Saeng;Kim, Seok-Gon;Lee, Seung-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.79-81
    • /
    • 1998
  • STATCOM can compensate industrial load's reactive power and filter the harmonic of nonlinear load's with the rapid dynamic response. In this paper, STATCOM is modelled to synchronous rotating coordinate by circuit dq transformation, and space vector PWM method is applied for broad voltage modulation. Also predict current controller is used for harmonic current filtering.

  • PDF