• Title/Summary/Keyword: PWM Method

Search Result 1,344, Processing Time 0.077 seconds

A Novel Control Algorithm of a Three-phase PWM Inverter with LC Filter (정현파 출력 필터를 가지는 3상 PWM 인버터 제어 기법)

  • Kim, Kwang-Seob;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.239-246
    • /
    • 2015
  • A novel control method of a three-phase PWM inverter with LC filter is proposed. The transfer function of LC filter is the same as that of second-order low pass filter(LPF), which has a zero damping ratio. A simple method of implementing second-order LPF with damping ratio is to add a resistor in an LC circuit. However, in a real power system, adopting damping resistors is impractical because it results in losses proportional to the square of the current flowing through the resistors. Instead of inserting resistors, the proposed control strategy utilizes the measured capacitor voltages to control the oscillation of LC circuit. The overall transfer function of the proposed method is the same as a second-order LPF, and its damping ratio is controllable via control variables. The current controller can have overshoots caused by LC filter. Improved current controller is implemented by an equivalent second-order of LC filter. A 7.5 kVA PWM converter and a PWM inverter with a 5.5 kW induction motor are set up to verify the proposed control algorithm. Test waveforms are also presented to verify the proposed LC filter control algorithm.

Experimental Study on Performance Evaluation of System Air-Conditioner using Compressor of PWM or Inverter Method (Cooling and Heating Characteristics) (PWM 방식과 인버터 방식의 압축기를 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(냉난방 특성))

  • 전용호;김대훈;허삼행;권영철;문제명;홍주태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.738-743
    • /
    • 2003
  • In the present study, the heating and cooling characteristics of system air-conditioner using a PWM compressor or a BLDC inverter compressor are investigated by the psychometric calorimeter using air enthalpy method. Cooling and heating capacities, power inputs and COPs are measured at the low, moderate, high loads under the cooling and heating standard conditions. At cooling conditions, the capacity of the PWM system is larger than that of the inverter case. Due to large power input, however, low COPs are measured under total load ranges. At heating conditions, the capacity of the PWM method is a little larger than that of the inverter case, except high load range. Since power input is low, large COPs are measured at moderate and high load ranges, which are different from cooling data. This shows that the PW system compared with the inverter case has good energy consumption efficiency at moderate and high load ranges except low load range. And when the system A/C is operated under the cooling and heating standard conditions, COPs are nearly uniform at total load ranges.

Design and implementation of BLDC motor drive logic using SVPWM method with FPGA (FPGA를 활용한 SVPWM방식의 정현파 BLDC 모터 구동 로직 설계 및 구현)

  • Jeon, Byeong-chan;Park, Won-Ki;Lee, Sung-chul;Lee, Hyun-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.652-654
    • /
    • 2016
  • This paper shows the Design and implementation of sinusoidal BLDC motor drive logic using SVPWM method with FPGA. Sinusoidal BLDC motor driver logic consists of sine-wave PWM generator, dead-time and lead angle control logic. PWM generator logic is designed using SVPWM method for increase of 15.5% linear domain than general sine-wave PWM. This logic is verified and implemented using Spartan-6 FPGA Board. Test results show that THD(Total Harmonic Distortion) of motor-driving current is 19.2% and rotor position resolution is 1.6 degree.

  • PDF

The Control of Single Phase High Power Factor PWM converter using Siding mode Observer without a source voltage sensor (슬라이딩 모드 관측기를 이용한 전원전압 센서없는 단상 PWM 컨버터의 고역율 제어)

  • 유지용;양이우;김영석
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.684-687
    • /
    • 1999
  • In this paper, a method for controlling a single phase PWM AC/DC converter without any voltage sensors is proposed. In this method, the source voltage is estimated by sliding mode observer and input current is synchronized with the estimated source voltage. The source voltage is estimated by current error between the actul and the estimated current. The experimental results confirm the validity of the proposed control method.

  • PDF

A Novel Random PWM Technique with a Constant Switching Frequency Utilizing an Offset Voltage (옵셋 전압을 이용한 일정 스위칭 주파수의 Random PWM 기법)

  • Kim, Do-Kyeom;Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.1
    • /
    • pp.67-74
    • /
    • 2017
  • This study proposes a novel random pulse-width modulation (PWM) technique with a constant switching frequency utilizing a random offset voltage. The proposed PWM technique spreads switching harmonics by varying the position of an active voltage vector without a switching frequency variation. The implementation of the proposed PWM technique is simple because it does not require additional hardware and complex algorithm. The proposed random PWM technique is compared with the conventional PWM technique on the factors of harmonic spectrum, total harmonic distortion, and harmonic spread factor to confirm the harmonic spread effect. The validity of the proposed method is verified by simulations and experiments on a three-phase inverter drive system.

An Efficient High Voltage Level Shifter using Coupling Capacitor for a High Side Buck Converter

  • Seong, Kwang-Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.125-134
    • /
    • 2016
  • We propose an efficient high voltage level shifter for a high side Buck converter driving a light-emitting diode (LED) lamp. The proposed circuit is comprised of a low voltage pulse width modulation (PWM) signal driver, a coupling capacitor, a resistor, and a diode. The proposed method uses a property of a PWM signal. The property is that the signal repeatedly transits between a low and high level at a certain frequency. A low voltage PWM signal is boosted to a high voltage PWM signal through a coupling capacitor using the property of the PWM signal, and the boosted high voltage PWM signal drives a p-channel metal oxide semiconductor (PMOS) transistor on the high side Buck converter. Experimental results show that the proposed level shifter boosts a low voltage (0 to 20 V) PWM signal at 125 kHz to a high voltage (370 to 380 V) PWM signal with a duty ratio of up to 0.9941.

Direct Duty Ratio Pulse Width Modulation Method for Matrix Converters

  • Li, Yulong;Choi, Nam-Sup;Han, Byung-Moon;Kim, Kyoung-Min;Lee, Buhm;Park, Jun-Hyub
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.660-669
    • /
    • 2008
  • This paper presents a new carrier based pulse-width modulation (PWM) method for matrix converters. By using the concept of average over one switching period, the modulation algorithm and the required equations are derived to synthesize the desired output voltage and to achieve the controlled input power factor. The proposed method uses a continuous carrier and the predetermined duty ratio signals to directly generate the gating signals and, thus, is referred to as "direct duty ratio PWM (DDPWM)". The feasibility and validity of the proposed method were verified by simulation and experiment.

A New Control Method for PWM AC Chopper (펄스푹 변조 교류포퍼를 위한 새로운 제어방)

  • 박창엽;김태곤;유주현;홍순석
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.8
    • /
    • pp.547-553
    • /
    • 1987
  • A new control method is proposed for PWM ac chopper whcih can have the features of both linear control of the fundamental voltage and complete elimination of the harmonics up to specified order. Through theoretical investigation of the proposed method, it is found that both input and output characteristics can be improved better than those of the conventional methods. Also the newly modified triangular carrier wave is suggested to perform the above features over full control range and to implement the control circuit easily. To evaluate the performances of the proposed PWM method, the comparsion with the conventional PWM technique is made and the exterimental results are suggested.

A New Dead Time Minimization Method for the Bridge Type PWM Converters (브리지 형태 PWM 변환기의 데드타임 최소화 방법)

  • Kim, Nam-Jeung;Lee, Eul-Jae;Oh, Won-Seok;Cho, Kyu-Min
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2715-2720
    • /
    • 1999
  • To prevent the short circuit of upper and lower arms of bridge type PWM converters as like a voltage source inverter and PWM AC/DC converter, the dead time is inserted in between two switching signals. As a result, unexpected errors are occurred. In this paper, a new dead time minimization method is proposed. According to the proposed method, very short time which is equal to the applied dead time or more short than it, is adopted at the time of current polarity is changing. Moreover, it can be operated with the polarity information of reference current in case of current control. With the experimental results. the varidity of proposed method is verified.

  • PDF

ave PWM Inverter (안정파PWM인버어터를 위한 새로운 디지털방식)

  • 정연택;한경희;이종수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.2
    • /
    • pp.80-88
    • /
    • 1988
  • As a method to improve harmonics in the voltage source PWM inverter, 5 level stair case wave method is used. The complementary transistor inverter (CTI) bridge circuit has this characteristics. This circuit required synchronous type 3 level PWM signal. In this paper, the 3 phase PWM digital signals within about 10 modulation error of the natural sampling was caculated, and a ROM table out of it for the digital signal of the control system was made. According to this table, the digital control method was proposed, and DTI circuit operated by this method was reviewed. It was confirmed to make V/F control possible by the select modulation ratio to the frequency.