• Title/Summary/Keyword: PWM Generator

Search Result 190, Processing Time 0.033 seconds

DC Bus Voltage Regulation With Six-Step Operation in Maritime DC Power System (식스 스텝 운전을 이용한 선박용 DC 전력 시스템의 직류단 전압 제어)

  • Yun, Jonghun;Son, Young-Kwang;Sul, Seung-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2021
  • Active AC/DC converters with PWM operation are utilized to regulate rectified DC bus voltage of a permanent magnet synchronous generator in the maritime DC power system. A DC bus voltage regulation strategy that exploits the six-step operation is proposed in this study. Compared with that of the PWM operation, switching loss of the converter can be significantly reduced under the six-step operation. Moreover, conduction loss can also be reduced due to the high modulation index and reduced flux-weakening current of the six-step operation. A controller is used for the proposed DC bus voltage regulation strategy to verify its validity with the simulation and experimental setup. The simulation and the experimental test results showed that the converter loss reduces to a maximum of 70% and 19%, respectively.

Switching Noise Reduction in Radiated from Three-Phase Induction Motor by Chaotic Random PWM Technique (카오스 랜덤 PWM기법을 이용한 3상 유도모터의 스위칭 소음저감)

  • Kim, J.H.;Jung, Y.G.;Oh, S.Y.;Lim, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.134-138
    • /
    • 2004
  • 본 연구에서는 카오스 랜덤 PWM(Chaotic Random PWM) 기법에 의한 3상 유도모터의 스위칭 소음 저감에 대하여 다루고 있다. 일반적으로 사용되고 있는 랜덤 발생기로서 선형일치발생기(Linear Congruential Generator : LCG)대신에 로지스트 사상(Logistic Map)의 분기도(Bifurcation Diagram)를 랜덤 발생기로 사용하였다. 카오스 랜덤수 발생기는 80C196 마이크로 콘트롤러가 전담하고 있으며, 80C196으로부터 발생된 카오스랜덤 수와 MAX038에 의하여 삼각파 랜덤 캐리어가 발생되고 있다. 1.5kw급 3상 유도모터 구동 시스템에 카오스 RPWM기법을 적용하여 모터전압 및 전류 그리고 스위칭 소음의 스펙트럼을 고찰하였다. 카오스 RPWM과 LCG에 의한 RPWM의 결과를 각각 비교하였으며 본 연구의 타당성을 입증하였다.

  • PDF

FPGA Based PWM Generator for Three-phase Multilevel Inverter

  • Tran, Q.V.;Chun, T.W.;Kim, H.G.;Nho, E.C.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.225-227
    • /
    • 2008
  • This paper deals with the implementation on a Field Programmable Gate Array (FPGA) of PWM switching patterns for a voltage multilevel inverter. The reference data in main microcontroller is transmitted to the FPGA through 16 general purpose I/O ports. Herein, three-phase reference voltage signals are addressed by the last 2-bit (bit 15-14) and their data are assigned in remaining 14-bit, respectively. The carrier signals are created by 16-bit counter in up-down counting mode inside FPGA according to desirable topology. Each reference signal is compared with all carrier signals to generate corresponding PWM switching patterns for control of the multilevel inverter. Useful advantages of this scheme are easy implementation, simple software control and flexibility in adaptation to produce many PWM signals. Some simulations and experiments are carried out to validate the proposed method.

  • PDF

Control and Analysis of Vienna Rectifier Used as the Generator-Side Converter of PMSG-based Wind Power Generation Systems

  • Zhao, Hongyan;Zheng, Trillion Q.;Li, Yan;Du, Jifei;Shi, Pu
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.212-221
    • /
    • 2017
  • Permanent-Magnet Synchronous Generators (PMSGs) are used widely in Wind Power Generation Systems (WPGSs), and the Vienna rectifier was recently proposed to be used as the generator-side converter to rectify the AC output voltage in PMSG-based WPGS. Compared to conventional six-switch two-level PWM (2L-PWM) converters, the Vienna rectifier has several advantages, such as higher efficiency, improved total harmonic distortion, etc. The motivation behind this paper is to verify the performance of direct-driven PMSG wind turbine system based-Vienna rectifier by using a simulated direct-driven PMSG WPGS. In addition, for the purpose of reducing the reactive power loss of PMSGs, this paper proposes an induced voltage sensing scheme which can make the stator current maintain accurate synchronization with the induced voltage. Meanwhile, considering the Neutral-Point Voltage (NPV) variation in the DC-side of the Vienna rectifier, a NPV balancing control strategy is added to the control system. In addition, both the effectiveness of the proposed method and the performance of the direct-driven PMSG based-Vienna rectifier are verified by simulation and experimental results.

Experimental Study on Conducted EMI Mitigation in SMPS using a Novel Spread Spectrum Technique

  • Premalatha, L.;Raghavendiran, T.A.;Ravichandran, C.
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.619-625
    • /
    • 2013
  • Switched mode power supplies (SMPS) are power electronic circuits extensively used in a wide range of applications. High frequency switching operation of SMPS causes electromagnetic emissions and has the potential to interfere with system operation, which in turn has an impact on system performance. This makes electromagnetic compatibility (EMC) an important concern. In this paper, a new and simple spread spectrum technique is proposed by modulating chaotic pulse position modulation (CPPM) and pulse width modulation (PWM). The resulting CPWM is implemented to reduce the conducted EMI in SMPS. The proposed method is found to be effective in reducing conduction EMI. The effectiveness and simplicity of the proposed method on spreading those dominating frequencies is compared to the EMI mitigation technique using an external chaotic generator. Finally, the levels of conductive EMI with standard PWM, CPWM with an external chaos generator and the proposed method are experimentally verified to comply with the CISPR 22A regulations. The results confirm the effectiveness of the proposed method.

Static Var Compensator Using Current Source PWM Converter (전류형 PWN 콘버어터의 희한 정지형 무효전력 보상장치에 관한연구)

  • 김철우;권순재;김광태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.11
    • /
    • pp.1183-1190
    • /
    • 1990
  • In this paper, instantaneous reactive power compensation algorithm is proposed and analyzed. The static Var generator developed in this paper is the current source PWM converter using hysteresis comparator method, which compensates the reactive power by detecting each instantaneous phase voltage and line current, independently. Some aspects on the static Var compensator-such as inductance, capacitance, hysteresis width, and switching frequency, etc.-are discussed. The dynamic performances are examined through digital simulation and experimental test.

  • PDF

Design of LED Driving Circuit using Voltage Controlled Ring Oscillator and Lighting Controller (전압제어 링 발진기를 이용한 LED구동회로 및 조명제어기설계)

  • Kwon, Ki-Soo;Suh, Young-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.1-9
    • /
    • 2010
  • An LED driving and control circuit has been developed. The LED driver has a new PWM circuit for current control of LED columns with dimming, current and thermal control, and communication functions. The PWM circuit is composed of two ring oscillator and one counter which can be constructed using basic digital logic components. In addition, it has the functions of remote control mode such as ON, OFF, emergency and power saving modes by the serial communication. The PWM generator and control circuit have been designed and fabricated 0.35[${\mu}m$] Magnachip/Hynix digital IC fabrication process. The LED driving and control board using the developed chip is fabricated and tested successfully.

Grid faults characteristics simulation of inverter-fed induction generator (인버터 부착형 농형 유도발전기의 계통고장특성 모의)

  • Hong, Jitae;Kwon, Soonman;Kim, Chunkyung;Lee, Jongmoo;Cheon, Jongmin;Kim, Hong-Ju;Kim, Heeje
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.43.1-43.1
    • /
    • 2011
  • The detail simulation modeling of fully-fed induction generator is investigated through PC based MATLAB/Simulink environment. Generator's stator currents are controlled by indirect vector control method. In this method, generator side converter controls the maximum excitation (air gap flux) by stator d-axis current and controls generator torque by stator q-axis current. Induction generator speed is controlled by tip speed ratio (TSR) upon the wind speed variations in order to generate the maximum output power. The generator torque model is specified as a 3-blade wind turbine with rating, then, the model is simulated under normal operating condition and three different fault conditions. The matlab model designed for fully-fed induction generator based wind farm provides good performance under normal and grid fault conditions. It provides good results for different pwm techniques and fault conditions except the single-phase line to ground fault, which should be verified with real time data from wind farms.

  • PDF

Study on the Operating Characteristics of Double Fed Induction Generator Connected AC network (계통 연계형 권선형 유도발전기의 동작특성 연구)

  • Kim, Chan-Ki;Han, Sang-Yul;Choo, Jin-Boo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.247-257
    • /
    • 2006
  • This paper shows the comparison of operating characteristics between squirrel cage induction generator and DFIG(Double Fed Induction Generator). Because squirrel cage induction generator consume the reactive power due to magnetizing reactance, the capacitor is need to compensate the reactive power. Otherwise, two back-to-back PWM voltage-fed inverters connected between the stator and the rotor allow sub/super synchronous operation with low distortion currents. In this paper, the response characteristics of squirrel cage induction generator and DFIG, were analyzed and investigated using PSCAD/EMTDC.