• 제목/요약/키워드: PWM Control

검색결과 2,049건 처리시간 0.041초

Current-Programmed Control of Three Phase PWM AC-AC Boost Converter

  • Choi, Nam-Sup;Li, Yulong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.414-416
    • /
    • 2005
  • In this paper, a new scheme of current programmed control for three phase PWM AC-AC converter is presented. By considering only the magnitude components, a similar scheme in the DC-DC converter can be extended to the three phase PWM AC-AC converter. The proposed current programmed control will be well adopted into various converter topologies though three phase PWM AC-AC boost converter is treated as an example. The converter analysis is carried out by applying the vector DQ transformation to obtain physical insight into the converter operation. Finally, the experiment result shows the validity of the proposed scheme.

  • PDF

적응 추정 기법을 이용한 PWM 인버터의 Dead Beat 제어 (Dead Beat Controlled PWM Inverter with On Line Parameter Estimation)

  • 노정욱;문건우;정영석;윤명중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.388-390
    • /
    • 1995
  • A new control scheme based on dead beat control with adaptive parameter estimation for PWM Inverter is proposed. The proposed scheme updates dead beat control parameters continouously, and make PWM inverter excellent performance at any load or parameter condition. Simulation results show very attractive features in this proposed scheme.

  • PDF

대형 동기 발전기 계자제어를 위한 PWM 인버터에 관한 연구 (A Study of PWM Inverter for Field Control on Large Synchronous Generator)

  • 류호선;이주현;임익헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.958-959
    • /
    • 2006
  • For the life extension of Jeju thermal power plant, digital PWM excitation system was replaced by KEPRI. This system consist of TMR(Triple Modular Redundant) controller, dual PWM power inverter for field current control and MMI etc. The Performance test during the commissioning verified the reliability of digital PWM excitation system and recently, this system has been operated successfully.

  • PDF

PWM인버터의 DC입력전달 맥동에 대한 고조파 적응제어 (Adaptive Harmonic Control for DC Input Voltage Fluctuation of PWM Inverter)

  • 이윤종;임남혁
    • 대한전기학회논문지
    • /
    • 제38권11호
    • /
    • pp.896-904
    • /
    • 1989
  • PWM techniques which eliminate and reduce harmonics of output voltage in PWM Inverter driving System with fluctuating input volotage are described. First, harmonic factors are analyzed from harmonic equation of general PWM waveform and by examination of control possiblity of each factor, controllable factor is selected. Applying controllable factor to NPWM, PWM techniques using reference wave and carrier wave modulation are introduced. Actually, by the experiment applied with this strategy, the reduction of harmonics of output voltage is confirmed.

  • PDF

공간 전류벡터를 이용한 PWM CSI 구동 유도전동기의 벡터제어 (Vector Controlled Induction Motor Drives Fed by PWM CSI Using Space Current Vectors)

  • 이동춘;고성범;노채균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.357-359
    • /
    • 1995
  • In this paper, vector control of induction motor drives using space current vector PWM is presented. The scheme gives advantages, besides robustness to inverter arm-shoot, sinusoidal input current and voltage for induction motors. In addition, space vector PWM for CSI produces faster transient response than conventional pattern PWM. Also, a modulation index control is proposed.

  • PDF

옵셋전압입력원리를 이용한 2상 인버터의 PWM 방식과 3상 인버터의 PWM 방식의 비교 (PWM Control Method for Two-Phase Inverter Using Offset Voltage Inserting Concept Comparing for its Method of three-Phase Inverter.)

  • 장도현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.498-499
    • /
    • 2014
  • 본 논문에서는 3상 PWM 옵셋전압방식을 응용하여 2상 인버터에 대한 PWM 제어방식을 확립하였다. 또한 기존의 3상 PWM 인버터 옵셋전압방식과의 최대 전압영역과 비교 분석하였다.

  • PDF

강압형 컨버터의 비선형 순시추종 PWM 제어기의 특성 분석 (Characteristic Analysis of Buck Converter by using the Non-Linear Instantaneous Following PWM Controller)

  • 라병훈;김상돈;권순걸;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.378-381
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of DC-DC converter. In this control method, the duty ratio of a switch is exactly equal to or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with buck converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM.

  • PDF

PWM 제어에 의한 솔레노이드-유량제어방식 ABS의 제동압력 특성 (Braking Pressure Characteristics of Solenoid-Flow Control Type ABS by PWM Control)

  • 송창섭;양해정
    • 한국정밀공학회지
    • /
    • 제14권8호
    • /
    • pp.146-154
    • /
    • 1997
  • Solenoid-folw control type ABS is used with a 'dump and reapply' pressure control arrangement instead of using 2/2 (normal open/close) solenoid valves in convensional systems(sol. -sol. control type), a flow control valve is used which replaces the (no) inlet valve. The flow control valve controls fluid flow providing a nearly constant reapply rate( .theta. ) after the dump plase of ABS operation. In this study, to investigate a characteristics of brake pressure by PWM control, test rig was consisted of ABS hydraulic modulator, digital controller, pneumatic power supply and brake master cylinder. For comparison with experi- mental results, system modelling and computer simulation were performed. As a result, experiment results showed fairly agreement with the simulation. Also, it is shown that the pressure gradient (tan .theta. ) is affected by pressure, frequency, duty ratio and expressed with an exponential funtion.

  • PDF

전압제어 링 발진기를 이용한 LED구동회로 및 조명제어기설계 (Design of LED Driving Circuit using Voltage Controlled Ring Oscillator and Lighting Controller)

  • 권기수;서영석
    • 조명전기설비학회논문지
    • /
    • 제24권4호
    • /
    • pp.1-9
    • /
    • 2010
  • LED구동회로및 제어회로를 개발하였다. 개발된 LED구동회로는 새로운 PWM회로를 가지고 있으며 LED열의 디밍, 전류 및 온도제어 및 통신 기능을 할 수 있다. 개발된 PWM회로는 기본적인 디지털 논리소자를 사용하여 만들어 질 수 있는 두 개의 링 발진기와 한 개의 카운터로 구성되어 있다. 부가적으로 이 회로는 온-오프 제어 모드, 비상모드, 전력절감모드를 가지고 있으며 직열통신을 이용해서 제어된다. 설계 된 PWM 발생기와 제어회로는 마그나칩/하이닉스의 디지털 공정을 이용하여 제작되었다. 제작된 칩은 LED구동장치와 제어기 보드에 장착되어 테스트 되었으며 성공적으로 동작하였다.

Advanced Control of a PWM Converter with a Variable-Speed Induction Generator

  • Ahmedt, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo;Tanaka, Toshihiko
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.97-108
    • /
    • 2007
  • This paper describes simple control structures for a vector controlled stand-alone induction generator (IG) for use under variable speeds. Different control principles, indirect vector control and deadbeat current control, are developed for a voltage source PWM converter and the three-phase variable speed squirrel-cage IG to regulate DC-link and generator voltages with a newly designed phase locked loop circuit. The required reactive power for the variable speed IG is supplied by means of a PWM converter and a capacitor bank to buildup the voltage of the IG without the need for a battery, to reduce the rating of the PWM converter while using only three sensors and to eliminate the harmonics generated by the PWM converter. These proposed schemes can be used efficiently for variable speed wind energy conversion systems. The measurements of the IG systems at various speeds and loads are given and show that these systems are capable of good AC and DC voltage regulation.