• Title/Summary/Keyword: PVDF Film

Search Result 182, Processing Time 0.023 seconds

Damage Monitoring for Wind Turbine Blade using Impedance Technique (임피던스 기법을 이용한 풍력 블레이드 손상 모니터링)

  • Huh, Yong-Hak;Kim, Jongil;Hong, Seonggu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.452-458
    • /
    • 2013
  • Impedance based monitoring technique was investigated to evaluate the damage occurring in wind turbine blade. In this study, PVDF film piezo sensors were patched on the 10 kW wind turbine blade, and impedance was measured over the frequency range of 1~200 MHz under fatigue loading. With applying fatigue loads on the blade, change in maximum deflection of the blade and local strain values could be obtained from the strain gages attached on the blade, and difference of the impedance signatures was also observed. From these data, it could be found that local damage or geometrical change in the blade structure happened. To quantitatively compare the impedance signature patterns, a statistical algorithm, scalar damage metric M was used. It was calculated from the impedance signatures considering fatigue loads and location of the sensors. The metric values were compared to correlate the metrics with damage in the blade.

Measurement of Ultrasonic Field Propagation Characteristics in Biological Tissues Using a Two-dimensional Array Hydrophone (2차원 배열 수중청음기를 이용한 생체조직에서의 초음파 음장 전파특성 측정)

  • ;;;;Xiu-Fen Gong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.76-82
    • /
    • 2001
  • Because the biological tissue with inhomogeneous acoustic properties does not keep a particular shape, the measurement of propagation characteristics of ultrasonic fields by the conventional scanning method with a miniature hydrophone is difficult. In this study, a two-dimensional may hydrophone was fabricated using the PVDF (Polyvinylidene fluoride) piezo-electric film and a ultrasonic field measurement system with it was established. For the acoustic field produced by a circular plan transducer with center frequency of 2.25㎒ and 13㎜ in diameter, it was possible to make a fairly accurate field measurement using the hydrophone system. The attenuation coefficients at 2.25 ㎒ for biological tissues were 0.7∼1.3 dB/cm(average; 1.0 dB/cm) in bovine liver, 1.0∼1.8 dB/cm (average; 1.6 dB/cm) in pig liver, 0.9∼2,9 dB/cm(average: 2.1 dB/cm) in bovine muscles, 1.7∼3.3 dB/cm (average; 2.5 dB/cm) in pig muscles.

  • PDF

Unconstrained REM Sleep Monitoring Using Polyvinylidene Fluoride Film-Based Sensor in the Normal and the Obstructive Sleep Apnea Patients (PVDF 필름 기반 센서를 이용한 정상인 및 폐쇄성 수면 무호흡증 환자에서의 무구속적인 렘 수면 모니터링)

  • Hwang, Su Hwan;Yoon, Hee Nam;Jung, Da Woon;Seo, Sang Won;Lee, Yu Jin;Jeong, Do-Un;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.3
    • /
    • pp.55-61
    • /
    • 2014
  • In sleep monitoring system, polysomnography (PSG) is the gold-standard but previous studies revealed that attaching numerous amount of sensors disturb sleep during the test which is the fundamental disadvantage of PSG. We suggest an unconstrained rapid-eye-movement (REM) sleep monitoring method measured with polyvinylidene (PVDF) film-based sensor for the normal and the obstructive sleep apnea (OSA) patients. Nine normal subjects and seventeen OSA patients have participated in the study. During REM sleep, rate and variability of respiration are known to be greater than in other sleep stages. Based on this phenomena, respiratory signals of participants were unconstrainedly measured using the PVDF-based sensor with the PSG and REM sleep were extracted from the average rate and variability of respiration. In epoch-by-epoch REM sleep detection, proposed method classified REM sleep with an average sensitivity of 72.3%, specificity of 92.5%, accuracy of 88.9%, and kappa statistic of 0.60 compared to the results of PSG. Student's t-test showed no significant difference between the results of normal and OSA group. This method is potentially applicable to REM sleep detection in homing environment or ambulatory monitoring.

Focal Length Control of Line-focus Ultrasonic Transducer Using Bimorph-type Bending Actuator (바이몰프형 밴딩 액츄에이터를 이용한 선집속형 초음파 트랜스듀서의 초점 거리 제어)

  • 채민구;하강열;김무준
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.202-207
    • /
    • 2003
  • For medical ultrasonic transducer, phase-weighting method has been used for controlling focal length with electric circuit at each vibrating element. However, the electric circuit is complex as the number of vibrating elements is increased. In this paper, we fabricated line-focus transducer with a bimorph-type piezoelectric actuator. The polyvinylidene fluoride (PVDF) piezoelectric type polymer film is used for transmitting and receiving of ultrasonic signal. Using this transducer, focal length of the transducer can be controlled mechanically by changing voltage of the actuator. It is confirmed that focal length of the transducer can be controlled in range of 1095 to radius of curvature.

A Study on Efficiency of Energy Conversion for a Piezoelectric Power Harvesting Using Polyvinylidene Fluorid Film (PVDF 필름을 이용한 효과적인 에너지 하베스팅에 관한 연구)

  • Hur, Won-Young;Lee, Tae-Yong;Lee, Kyung-Chun;Hwang, Hyun-Suk;Song, Joon-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.422-426
    • /
    • 2011
  • Piezoelectric materials can be used to convert mechanical energy into electrical energy. In this study, we investigated the possibility of harvesting from mechanical vibration force using a high efficient piezoelectric material-polyvinylidene fluoride (PVDF). A piezoelectric energy harvesting system consists of rectifier, filter capacitor, resistance. The experiments were carried out with impacting force to PVDF film with the thickness of 1 ${\mu}m$. The output power was measured with change in the load resistance value from 100 ${\Omega}$ to 2.2 $M{\Omega}$. The highest power was obtained under optimization by selection of suitable resistive load and capacitance. A power of 0.3082 ${\mu}W/mm^2$ was generated at the external vibration force of 5 N (10 Hz) across a 1 $M{\Omega}$ optimal resistor. Also, the maximum power of 0.345 ${\mu}W/mm^2$ was generated at 22 ${\mu}F$ and 1 $M{\Omega}$. The developed system was expected at a solution to overcome the critical problem of making up small size energy harvester.

Experimental study on the Organic Ferroelectric Thin Film on Paper Substrate (유기 강유전 박막의 종이기판 응용가능성 검토)

  • Park, Byung-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2131-2134
    • /
    • 2015
  • In this study, It has been demonstrated a new and realizable possibility of the ferroelectric random access memory devices by all solution processing method with paper substrates. Organic ferroelectric poly(vinylidene fluoride-trifluoroethylene) (P(VDF-TrFE)) thin films were formed on paper substrate with Al electrode for the bottom gate structure using spin-coating technique. Then, they were subjected to annealing process for crystallization. The fabricated PVDF-TrFE thin films were observed by scanning electron microscopy (SEM) and atomic force microscopy (AFM). It was found from polarization versus electric field (P-E) measurement that a PVDF-TrFE thin film on paper substrate showed very good ferroelectric property. This result agree well with that of a PVDF-TrFE thin film fabricated on the rigid Si substrate. It anticipated that these results will lead to the emergence of printable electron devices on paper. Furthermore, it could be fabricated by a solution processing method for ferroelectric random access memory device, which is reliable and very inexpensive, has a high density, and can be also fabricated easily.

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.

Combinational flexible OLED display device using piezoelectric polymer PVDF (압전폴리머 PVDF를 이용한 복합형 유연 OLED 디스플레이 소자)

  • Le, Sang-Yub;Bea, Byung-Tack;Park, Dong-Hee;Choi, Ji-Won;Choi, Won-Kook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.55-55
    • /
    • 2008
  • 압전폴리머 PVDF(polyvinylidene difluoride)의 기판소재를 기반으로 한 디스플레이 소자를 연구하였다. 압전 폴리머 PVDF의 양면은 두께 300nm정도의 ITO(Indium Tin Oxide)를 TCO(Transparent conducting oxide)로 R2R(roll to roll)증착하였으며, 이를 적외선 계열 Pulsed Laser로 상온 건식 에칭을 통해 패턴해내고, 이후 고진공 환경에서 Alq3 를 기반의 유기발광소자를 제작하였다. 전기적 신호에 대해서 기계적인 작동이 가능한 투명 압전 폴리머 재료를 디스플레이 발광소자의 기판 소재로 사용함으로써, 궁극적으로 발광기능과 더불어 압전효과에 의한 스피커 기능이 한 개의 개체내에서 독립적으로 구현될 수 있도록 설계하고, 기술적으로 실현시켰다는 점이 본 연구의 의의라고 할 수 있다. 이를 위해서, 섭씨 80도 이상의 온도에서 압전 성질을 상실하는 것으로 알려진 PVDF에 대해서 투명산화전극을 레이져를 이용한 비가열식 승화방법을 통해 패턴화하는 것을 사용했으며, 밀리미터 단위에서 수십 마이크로미터 수준까지 패턴화할 수 있었다. 제작된 복합형 유연 OLED소자는 기계적으로 휘어진 상태에서도 발광 성능과 스피커 성능을 각각 독립적으로 보였으며, Alq3에 의한 녹색발광을 보임을 확인하였고, 이 경우 양자효율은 약 3%이하의 값을 보였다. 또한 각주파수별 음압(SPL: Sound Pressure Level)측정 결과는 압번폴리머가 가청주파수 영역에서 작동함을 보였으며, 고주파영역에서의 SPL값이 증가하는 전형적인 PVDF사용 필름 스피커의 특성을 보였다. 이로부터 제작된 복합형 소자는 본 연구에서 제안된 목적에서 보인 것과 같이, 두 개의 기능이 서로간의 간섭없이 독립적으로 한 개의 개체 내에서 작동함을 확인할 수 있었다. 본 연구 결과로부터 새로운 유연 전자 소자에 대한 디자인 개념을 제시하고, 기타 다른 기능이 접합된 형태의 신개념 전자 소자를 제안하는 것도 가능할 것으로 기대된다.

  • PDF

A Study on the Ultrasonic Response Characteristic of PVDF Organic Thin Film by Physical Vapor Deposition Method (진공증착법으로 제조된 PVDF 유기박막의 초음파 응답 특성에 관한 연구)

  • Park, Soo-Hong
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.221-228
    • /
    • 2009
  • The purpose of this paper is to discuss the fabrication of $\beta$-PVDF($\beta$-Polyvinylidene fluoride, $\beta$-PVF2) organic thin films through the vapor deposition method and to investigate the ultrasonic response properties of the organic thin films produced. Vapor deposition was performed under the following conditions : the temperature of evaporator, the applied electric field and the pressure of reaction chamber were $270^{\circ}C$, 142.4 kV/cm and $2.0{\times}10^{-5}\;Torr$, respectively. The results showed that the degree of crystallinity increased from 47% to 67.8% with an increase in the substrate temperature. In the case of a sensor response characteristic by varying the distance from 1cm to 100cm, the output voltage decreased from 0.615V to 0.4V.