• Title/Summary/Keyword: PVDF 중공사막

Search Result 21, Processing Time 0.033 seconds

Preparation of PVDF Hollow Fiber Membrane via TIPS (Thermally Induced Phase Separation) and Stretching (열유도 상분리와 연신공정을 이용한 PVDF 중공사막의 제조)

  • Park, Minsoo;Kim, Jinho;Jang, Moonseog;Kim, Sung Soo
    • Membrane Journal
    • /
    • v.24 no.2
    • /
    • pp.158-166
    • /
    • 2014
  • In this research, microporous and bicontinuous poly vinylidene fluoride(PVDF) hollow fiber membranes were prepared via hybrid process of the thermally induced phase separation (TIPS) and stretching method. The mechanism of the membrane preparation is based on liquid-liquid phase separation. The final membranes have characteristic structures which have both bicontinuous and fibrillar morphology by applying the stretching method. They showed quite different structure when compared with the spherulitic or nodular structure from S/L TIPS and bicontinuous structure from L/L TIPS. At first, PVDF hollow fiber precursors were prepared via TIPS method using various kind of diluent mixtures. We used gamma-butyrolacton, dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP) as diluents. We could make hollow fiber membranes which had porous outer surface or dense outer surface by controling the parameters such as cooling conditions, PVDF concentration and the ratio of diluent mixtures. Finally, these hollow fiber were stretched at room temperature and diluents were extracted by ethanol. Effects of the stretching ratio on the membrane morphology were investigated using scanning electron microscope (SEM), and its effects on water flux, porosity, pore size, roughness and tensile strength were examined.

Preparation of PVDF Hollow Fiber Membrane and Absorption of SO2 from Flue Gas Using Bench Scale Gas-Liquid Contactor (PVDF 중공사막 제조 및 벤치규모 기-액 접촉기를 이용한 SO2 흡수특성)

  • Park, Hyun-Hee;Jo, Hang-Dae;Kim, In-Won;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.46 no.3
    • /
    • pp.521-528
    • /
    • 2008
  • The micro-porous asymmetric PVDF hollow fiber membranes for gas-liquid contactor were prepared by the dry-jet wet phase inversion process and the characteristics of hollow fiber membranes were evaluated by the gas permeation method and scanning electron microscope. The chemical absorbent for removal of $SO_2$ gas was sodium hydroxide at bench scale hollow fiber membrane contactor. The experiments were performed in a counter-current mode of operation with gas in the shell side and liquid in the fiber lumen of the module to examine the effect of various operating variables such as concentration of absorbent, gas flow rate, L/G ratio and concentration of inlet $SO_2$ gas on the $SO_2$ removal efficiency using PVDF hollow fiber membrane contactor. Membrane mass transfer coefficient($k_m$) was calculated by mathematical modeling. The volumetric overall mass transfer coefficient increased with increasing the concentration of absorbent and L/G ratio. The increase of the absorbent concentration and L/G ratio not only provides more sufficient alkalinity but also decreases liquid phase resistance. The volumetric overall mass transfer coefficient increased with increasing gas flow rate due to decreasing the gas phase resistance.

Thermophilic Hydrogen Production from Microbial Consortia Using PVDF Membrane Bioreactor (PVDF 여과막 생물막 반응기를 이용한 혐기 세균 복합체의 고온 수소생산)

  • Oh, You-Kwan;Lee, Dong-Yeol;Kim, Mi-Sun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.3
    • /
    • pp.223-229
    • /
    • 2007
  • 여과막 생물반응기를 이용하여 $60^{\circ}C$에서 혐기 세균 복합체가 포도당으로부터 수소를 생산할 수 있는 최적조건을 연구하였다. 여과막 생물반응기는 연속교반 탱크반응기와 외부에 장착된 PVDF (polyvinylidene fluoride) 중공사막 여과장치로 구성되었다. 접종슬러지는 하수처리장 소화 슬러지조에서 얻었고, 포자형성 수소생산 미생물을 얻기 위해 $90^{\circ}C$에서 20분 간 열처리하였다. 16S rRNA PCR-DGGE(polymer chain reaction-denaturing gradient gel electrophoresis) 분석을 통해 열처리 전후의 미생물상 변화를 조사하였다. 열처리 후 DGGE 밴드의 수는 감소하였고, 주요 밴드는 Clostridium perfringens와 유사한 염기서열을 나타내었다. 운전 기간 동안 바이오가스 내 수소함량은 60%(v/v)를 유지하였고, 메탄은 검출되지 않았다. 연속교반 탱크반응기를 여과막 없이 수력학적 체류 4시간에서 운전하였을 때 공급된 포도당의 95.0%가 제거되었고, 이때 균체농도 및 수소생산속도는 각각 1.35 g cell/L 및 7.4 L $H_2$/L/day이었다. 동일한 체류시간에서 PVDF중공사막 여과장치를 장착하여 연속교반 탱크반응기를 운전하였을 때, 균체농도는 1.62 g cel/L로 증가하였고 높은 포도당 제거율(99.5%) 및 수소생산속도(8.8 L $H_2$/L/day)가 관찰되었다. 40 nm 및 100 nm의 공극크기를 가진 여과막은 균체농도 및 수소생산 측면에서 유사한 성능을 나타내었다. 여과막 생물반응기는 여과막의 반복적인 세척을 통해 30일 이상 안정적으로 운전될 수 있었다.

An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber (PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구)

  • Joo, Hongjin;Kwak, Heeyoul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.

Preparation of Composite Membranes Via PVA/PAM Solution Coating onto Hydrophilized PVDF Hollow Fiber Membrane and Their Pervaporation Separation of Water-ethanol Mixture (PVDF 중공사막의 표면친수화 후 PVA/PAM 용액의 코팅을 통한 복합막제조와 이의 물-에탄올계의 투과증발 분리)

  • Kim, Ji Seon;Park, Chae Young;Park, Hun Whee;Seo, Chang Hee;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.23 no.4
    • /
    • pp.312-318
    • /
    • 2013
  • Poly vinylidene fluoride (PVDF) hollow fiber membranes were hydrophilized using polyethylenimine (PEI) and p-xylylene dichloride (XDC), and poly(vinyl alcohol) (PVA) and poly (acrylic acid -co- maleic acid) (PAM) mixed solutions by varying the concentration of PAM were coated onto PVDF membrane surface. The surface coating was verified by the observation of scanning electron microscope (SEM) and the permselective characteristcs of the resulting composite membranes were tested for 90 wt% aqueous ethanol solution by the pervaporation technique. The effects of the corsslinking agent concentraion, the temperature of feed solution, and the reaction temperature on the flux and separation factors were measured. Typically, the flux, $1,480g/m^2hr$ at the reaction temperature $100^{\circ}C$, PAM 3 wt%, feed temperature $70^{\circ}C$ was obtained, on the other hand, for the separation factor, ${\alpha}_{W/E}=82$ at the conditions of the reaction temperature $100^{\circ}C$, PAM 15 wt% and feed temperature $25^{\circ}C$ was shown.

Measurement of Liquid Entry Pressure of PE and PVDF Hollow Fiber Membranes in Membrane Distillation Process (막증류 공정에서 PE 및 PVDF 중공사막의 액체투과압력 측정에 관한 연구)

  • Min, Ji Hee;Park, Min Soo;Kim, Jinho
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.216-222
    • /
    • 2015
  • The method measuring LEP (liquid entry pressure) was optimized to evaluate the wettabilities of hydrophobic membranes which might affect long-term durability of membrane in MD (membrane distillation) process. Conductivity of the permeate was monitored to measure the LEPs of PE (polyethylene) and PVDF (polyvinylidene di-fluoride) hollow fiber membranes from highly concentrated synthetic feed water of 20 wt% NaCl. Holding time over 5 min and the ratio of membrane area to the tank volume more than $10m^2/m^3$ were required to ensure LEP value.

A Study on the Absorption of Carbon Dioxide using PVDF/Plasma Membrane Contactor (PVDF/플라즈마 막접촉기를 이용한 이산화탄소의 흡수에 관한 연구)

  • Choi, Seung-Hak;Gao, Tongzhai;Oh, Sae-Joong
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.161-169
    • /
    • 2005
  • Numerical simulation and experiments were carried out on the absorption of carbon dioxide using PVDF hollow-fiber membrane contactor. Water or monoethanolamine (MEA) aqueous soluton was used as absorbents. Simulation results showed that the concentration profile of carbon dioxide was less affected by the flow rate of MEA than that of water absorbent. The absorption rate and mass transfer coefficient of carbon dioxide increased as the concentration of MEA increased. The mass transfer coefficients obtained by experiments coincided with those obtained by numerical simulation and theoretical results for $CO_2-water$ system. However, for $CO_2-MEA$ system, the mass transfer coefficients obtained by experiments were lower than those obtained by simulation, while the simulation results agreed well with theoretical results. The durability of plasma-treated hollow fiber membranes was better than that of no plasma-treated ones.

Preparation and Performance of Low Pressure PVDF Nano-composite Hollow Fiber Membrane Using Hydrophilic Polymer (친수화 고분자 소재를 이용한 저압용 PVDF 나노복합중공사막의 제조 및 성능 연구)

  • Park, Cheol Oh;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.28 no.5
    • /
    • pp.361-367
    • /
    • 2018
  • In this study, the nanofiltration (NF) composite membranes for the low pressure use were prepared using polyvinylidene fluoride (PVDF) hollow fiber membrane as a supporter. Poly styrene sulfonic acid (PSSA) and polyethyleneimine (PEI) were coated onto the PVDF membrane by both layer-by-layer and salting-out methods. To characterize the prepared NF membranes in terms of the flux and salt rejection, 100 mg/L feed solutions of NaCl, $MgCl_2$, and $CaSO_4$ were used at the flow rate of 1 L/min and the operating pressure of 2 bar at room temperature. The NF membranes coated with 20,000 ppm PSSA (ionic strength 1.0) solution for 3 minutes and then 30,000 ppm (ionic strength 0.1) solution for 1 minute were observed the best performance. The permeability and salt rejection were 38.5 LMH, 57.1% for NaCl, 37.9 LMH and 90.2% for $MgCl_2$ and 32.4 LMH and 54.6% for $CaSO_4$, respectively.