• Title/Summary/Keyword: PVC membrane

Search Result 169, Processing Time 0.027 seconds

Test on the Mechanical Characteristics of Glass Fiber Membrane (유리섬유 막재의 역학적 특성에 관한 시험)

  • Park, Kang-Geun;Yoon, Sung-Kee
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.2
    • /
    • pp.55-62
    • /
    • 2008
  • Membrane structures are now used in various ways throughout the world with the merits of free shape, lightness, durability, sunlight transmittance and homogeneous material. The development of new membrane material opened up new possibility for the design of new building structures. Recently it was mainly used PVC, PVF, PVDF, PTFE, ETFE membrane for using the roofing material of membrane structures. Some problems of membrane materials have fire proofing, lack of strength, self cleaning capacity, tear resistance, durability, heat insulation, sound insulation and elasticity. For the solution of this problems, it will be tested the mechanical properties of membrane material about tensile strength, tearing resistance, etc.

  • PDF

Preparation of Poly(vinyl chloride)-graft-poly(styrene sulfonic acid) Composite Nanofiltration Membranes (폴리비닐클로라이드-그래프트-폴리스티렌 술폰산 복합 나노막 제조)

  • Kim, Jong-Hak;Park, Jung-Tae;Koh, Joo-Hwan;Roh, Dong-Kyu;Seo, Jin-Ah
    • Membrane Journal
    • /
    • v.18 no.2
    • /
    • pp.132-137
    • /
    • 2008
  • Nanofiltration membranes were prepared based on coating a sulfonated comb-like copolymer layer on top of a poly(vinylidene fluoride) (PVDF) support. The comb-like copolymer comprising poly(vinyl chloride) backbone and poly(styrene sulfonic acid) side chains, i.e. PVC-g-PSSA was synthesized by atom transfer radical polymerization (ATRP) using direct initiation of the secondary chlorines of PVC. The successful synthesis of graft copolymers were confirmed by nuclear magnetic resonance ($^1H$-NMR), FT-IR spectroscopy and wide angle X-ray scattering (WAXS). Composite nanofiltration membranes consisting PVC-g-PSSA as a top layer exhibited the increase of both rejections and solution flux with increasing PSSA concentration. This performance enhancement is presumably due to the increase of SO3H groups and membrane hydrophilicity. The rejections of composite membranes containing 71 wt% of PSSA were 88% for $Na_2SO_4$ and 33% for NaCl, and the solution flux were 26 and $34L/m^2h$, respectively, at 0.3 MPa pressure.

Novel Silver(I) Ion Selective PVC Membrane Electrode Based on the Schiff Base (N2E,N2'E)-N2,N2'-Bis(Thiophen-2-ylmethylene)-1,1'-Binaphthyl-2,2'-Diamine

  • Jeong, Eunseon;Ahmed, Mohammad Shamsuddin;Jeong, Hae-Sang;Lee, Eun-Hee;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.800-804
    • /
    • 2011
  • A potentiometric sensor based on the Schiff base $(N^2E,N^{2'}E)-N^2,N^{2'}$-bis(thiophen-2-ylmethylene)-1,1'-binaphthl-2,2'-diamine has been synthesized and explored as an ionophore PVC-based membrane sensor selective for the silver ($Ag^+$) ion. Potentiometric investigations indicate a high affinity of this receptor for the silver ion. Seven membranes have been fabricated with different compositions, with the best performance shown by the membrane with an ionophore composition (w/w) of: 1.0 mg, PVC: 33.0 mg, DOA: 66.0 mg in 1.0 mL THF. The sensor worked well within a wide concentration range of $1.0{\times}10^{-2}$ to $1.0{\times}10^{-7}$ M, at pH 5, at room temperature (slope 57.4 mV/dec.), and with a rapid response time of 9 s; the sensor also showed good selectivity towards the silver ion over a huge number of interfering cations, with the highest selectivity coefficient for $Hg^{2+}$ at -3.7. Thus far, the best lower detection limit was $4.0{\times}10^{-8}$ M.

Preparation of Ag Nanoparticles by Templating Poly(vinyl chloride)-g-poly(styrene sulfonic acid) Graft Copolymer Membrane (Poly(vinyl chloride)-g-poly(styrene sulfonic acid) 가지형 공중합체막을 이용한 은 나노입자 제조)

  • Byun, Su-Jin;Seo, Jin-Ah;Chi, Won-Seok;Shul, Yong-Gun;Kim, Jong-Hak
    • Membrane Journal
    • /
    • v.21 no.1
    • /
    • pp.39-45
    • /
    • 2011
  • An amphiphilic graft copolymer consisting of a poly(vinyl chloride) (PVC) backbone and poly(styrene sulfonic acid) (PSSA) side chains (PVC-g-PSSA) was synthesized via atom transfer radical polymerization (ATRP). This polymer electrolyte membrane was ion-exchanged to Ag ions by immersing in 10 wt% $AgNO_3$ aqueous solution and templated the growth of Ag nanoparticles by a reducing agent. The formation of Ag nanoparticles was confirmed using UV-visible spectroscopy and X-ray diffraction (XRD). Transmission electron microscopy (TEM) revealed that utilization of $NaBH_4$ was the most effective in the formation of Ag nanoparticles with 10~15 nm in size. The formation of Ag nanoparticles was also strongly affected by the concentration of reducing agent and reduction time.

Determination of Nitrate in Chromium Plating Solution with Nitrate-Selective Electrodes

  • 강유라;이원;허황;차근식;남학현
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.3
    • /
    • pp.221-226
    • /
    • 1995
  • A method for determining nitrate in post treatment chromium plating solutions with PVC-based nitrate-selective electrodes is described. PVC-based nitrate-selective membranes which contain TDMANO3 ion-exchanger in PVC/NPOE, PVC/DOA or PVC/DBP matrices, and a commercially available Corning electrode (No. 476134) have been compared in respect of their detection limits, response slopes, selectivities at various pHs, and dynamic response to the hydrochromate ion in basic condition. The PVC/DBP/TDMANO3 membrane electrode was chosen as the ISE detector for the determination of nitrate in the presence of hydrochromate interference. The amount of nitrate in real post treatment chromium plating solution could be determined successfully with this electrode in both static and flow-injection measurements when the sample was properly diluted with an alkaline buffer.

Treatment of Nitrogen Oxides in Ambient Air using a Ion-Selective Electrode (대기중 질산화물의 이온 선택성 전극에 의한 처리)

  • 안형환;우인성;강안수;이영순;김윤선
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.2
    • /
    • pp.40-49
    • /
    • 1990
  • For the determination of polluant NOx in ambient air, nitrate ion-selective electrode(ISE) was made. To comparison of NOx in each method, the nitrate-ISE, NEBA, Orion electrode were used to determinee NOx in ambient air. In this work, the concentration of NOx in ambient air was average 0.06ppm. The results were good agreement with those obtained by each method within a relative error of 3%, Absorbing efficiency of nitrogen oxides in ambient air was good for Alkali solution. The determination of nitrogen oxides in ambient air using the Aliquat 336N-PVC membrane electrode was one of the useful method. The best characteristics of the Aliquat 336N-PVC me,mbrane electrode were obtained with the ion-exchanger concentration level of 6.5-9.1 percent by weight. The optimal membrane composition, was 9.09wt.% of ion-exchanger, 30.95wt.% of PVC, 60.6wt.% of plasticizer (DBP), and 0.5mm of thickness. Under the above condition, the electrode approached the Nernstian slope most closely, and the linear response ranges produced the best results.

  • PDF

Titanium Acetylacetonate as an Excellent Ion-Carrier in Construction of Iodide Sensor

  • Ganjali, Mohammad Reza;Daftari, Azadeh;Mizani, Farhang;Salavati-Niasari, Masoud
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.1
    • /
    • pp.23-26
    • /
    • 2003
  • Titanium acetylacetonate was used in the construction of a PVC-based membrane electrode. This sensor shows very good selectivity for iodide ion over a wide variety of common inorganic and organic anions. It exhibits Nernstian behavior with a slope of 59.1 mV per decade. The working concentration ranges of the sensor are with a detection limit of $3.0\;{\times}\;10^{-6}\;M$. The response time of the sensor is very fast (<8 s), and can be used for at least twelve weeks in the pH range of 4.0-9.2. The best performance was obtained with a membrane composition of 30% PVC, 65% dibutylphthalate, 3% titanium acetylacetonate and 2% hexadecyltrimethylammonium bromide. The proposed sensor was successfully applied as an indicator electrode for titration of iodide with silver ion.

Study on the Preparation of Polyvinyl Chloride Anion Exchange Membrane as a Separator in the Alkaline Water Electrolysis (알칼리 수전해용 격막으로서 폴리염화비닐(polyvinyl chloride) 음이온교환막의 제조에 관한 연구)

  • Park, Jong-Ho;Bong, Soo-Yeon;Ryu, Cheol-Hwi;Hwang, Gab-Jin
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.469-474
    • /
    • 2013
  • An anion exchange membrane was prepared for a separator in the alkaline water electrolysis. An anion exchange membrane was prepared by the chloromethylation and amination of polyvinyl chloride (PVC) used as a base polymer. The membrane properties of the prepared anion exchange membrane such as the membrane resistance and ion exchange capacity were measured. The minimum membrane resistance of the prepared anion exchange membrane was $2.9{\Omega}{\cdot}cm^2$ in 1M NaOH aq. solution. This membrane had 2.17 meq./g-dry-membrane and 43.4% for the ion exchange capacity and water content, respectively. The membrane properties of the prepared anion exchange membrane was compared with that of the commercial anion exchange membrane. The membrane resistance decreased in the order; AHT>IOMAC> Homemade membrane> AHA>APS=AFN. The ion exchange capacity decreased in the order; Homemade membrane>AFN>APS>AHT>AHA>IOMAC.

Salphen H2 as a Neutral Carrier for the Uranyl Ion-Selective PVC Membrane Sensor

  • Kim, Dong-Wan;Park, Kyeong-Won;Yang, Mi-Hyi;Kim, Jin-eun;Lee, Shim-Sung;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.6
    • /
    • pp.899-902
    • /
    • 2006
  • The complexation of N,N'-4,5-(ethylenedioxy)benzenebis(salicylideneimine), (salphen$H_2$) with uranyl ion was studied in acetonitrile solution spectrophtometrically, and the formation constant of the resulting 1 : 1 complex was evaluated. The salphen$H_2$ ligand was used as an ionophore in plasticized poly(vinyl chloride) (PVC) matrix membrane sensor for uranyl ion. The prepared sensors exhibited a near Nernstian response, 28.0-30.9 mV/decade for uranyl ion over the concentration range $1.0\;{\times}\;10^{-2}$ to $1.0\;{\times}\;10^{-6}$M with a limit of detection of $3.2\;{\times}\;10^{-7}$ M. The proposed electrode could be used at a working pH range of 1.5 - 4.0.

Copper(II) Selective PVC Membrane Electrodes Based on Schiff base 1,2-Bis (E-2-hydroxy benzylidene amino)anthracene-9,10-dione Complex as an Ionophore

  • Jeong, Eun-Seon;Lee, Hyo-Kyoung;Ahmed, Mohammad Shamsuddin;Seo, Hyung-Ran;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.2
    • /
    • pp.401-405
    • /
    • 2010
  • The Schiff base 1,2-bis(E-2-hydroxy benzylidene amino)anthracene-9,10-dione has been synthesized and explored as ionophore for preparing PVC-based membrane sensors selective to the copper ($Cu^{2+}$) ion. Potentiometric investigations indicate high affinity of these receptors for copper ion. The best performance was shown by the membrane of composition (w/w) of ionophore: 1 mg, PVC: 33 mg, DOP: 66 mg and KTpClPB as additive were added 50 mol % relative to the ionophore in 1 ml THF. The proposed sensor's detection limit is $2.8{\times}10^{-7}$ M over pH 5 at room temperature (Nernstian slope 31.76 mV/dec.) with a response time of 15 seconds and showed good selectivity to copper ion over a number of interfering cations.