• 제목/요약/키워드: PV systems

검색결과 601건 처리시간 0.029초

액티브필터 기능을 가진 태양광발전시스템(PV-AF 시스템)의 MPPT제어법에 따른 출력특성비교 (Comparison of the operational characteristics of the PV-AF system according to the various MPPT controls)

  • 박민원;김봉태;이재득;성기철;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.325-327
    • /
    • 2001
  • So far, because the photovoltaics power generation system can be treated to a harmonics source for the power distribution systems, the PV system combined the function of AF systems as well as the AF systems using the PV module as the power source have never been reported. However, authors have recently proposed a novel concept of the photovoltaics power generation system adding the function of the active filter (PV-AF system). In this paper, in order to confirm the operational characteristics of the PV-AF system, various MPPT controls are applied and analyzed.

  • PDF

태양광 발전과 에너지저장시스템을 활용한 모빌리티 충전 시스템의 제어 방법 (Control Strategies of Mobility Charging Systems Using PV-ESS Systems)

  • 김대원;이현민;박성민
    • 전력전자학회논문지
    • /
    • 제26권5호
    • /
    • pp.334-341
    • /
    • 2021
  • Operation modes and control strategies for single-phase mobility charging station utilizing photovoltaic (PV) generation and energy storage systems (ESS) are proposed. This approach generates electric power from PV to transmit the mobility, ESS, and then transfer it to the grid when surplus electric power is generated during daytime. However, the PV power cannot be generated during night-time, and ESS and the mobility system can be charged using grid power. The power balance control based on power fluctuations and the resonant current control that can compensate harmonic components have been added to increase the stability of the system. The MATLAB/Simulink simulation was carried out to verify the proposed control method, and the 2-kW single-phase grid-tied PV-ESS smart mobility charger was built and tested.

엑티브필터 기능을 추가한 새로운 태양광 발전시스템의 제안 (Novel Concept of Shunt Active Filter Function Added in PV Generation System)

  • 김봉태;박민원;성기철;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.296-300
    • /
    • 2001
  • Novel concept of shunt active filter (AF) function added in Photovoltaic (PV) generation system is described in this paper. So far, for the PV generation system has been treated as one of harmonic sources to the power distribution systems, not only a PV system combined with AF but also AF systems using PV module as their power source have never been discussed. The basic structure and control strategy of the PV-AF system are, for the first time, introduced in this work. In order to stabilize the output current of voltage source inverter (VSI), the reference voltage MPPT control is applied. Simulation analysis shows that it is possible to combine AF function to the three-phase grid-connected PV generation system without any physical difficulties, and the performance of the proposed PV-AF system is acceptable and stable as well.

  • PDF

스위칭방식 PV Simulator의 전력회로와 LCL필터 설계 (A Design of Power Circuit and LCL Filter for Switching Mode PV Simulator)

  • 이성민;유태식;김효성
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.431-437
    • /
    • 2012
  • PV simulators are essential equipment for testing power conditioning systems (PCS) which are one of an important part in PV generator systems, for testing before shipment. High dynamic PV simulator is required since MPPT(Maximum Power Point Tracking) test procedure has been established by EN50530 regulation recently. Most high quality PV simulator prevailed in the market is linear type which however has low efficiency. This paper proposes design guide lines for the power stage and LCL type filter cooperating with a switching mode PV simulator that shows high efficiency and very low power consumption. Proposed theory is verified by experiment.

수상 태양광 발전 부유체에 대한 풍하중과 파랑하중을 통한 전산 해석과 설계적 방법의 비교 연구 (Comparative Study of Effect of Wind and Wave Load on Floating PV: Computational Simulation and Design Method)

  • 이규한;최지웅;서지현;하호진
    • 한국기계가공학회지
    • /
    • 제18권11호
    • /
    • pp.9-17
    • /
    • 2019
  • Interest in renewable energy is rapidly growing around the world. One of the most popular renewable energy sources is solar power, and photovoltaic (PV) systems are the most representative route for generating solar energy. However, with the growing adoption of solar power systems, the demand for land on which to install these systems has increased, which has caused environmental degradation. Recently, floating PV systems have been designed to utilize idle water surface areas of dams, rivers, and oceans. Because floating PV systems will be exposed to harsh environmental stresses, the safety of such systems should be secured before installation. In this study, the structural robustness of a floating PV system was analyzed by conducting numerical simulation to investigate whether the system can withstand harsh environmental stresses, such as wind and wave loads. Additionally, conventional wind and wave load predictions based on the design method and the simulation results were compared. The comparison revealed that the design method overestimated wind and wave loads. The total drag of the PV system was significantly overestimated by the conventional design criteria, which would increase the cost of the mooring system. The simulation offers additional advantages in terms of identifying the robustness of the floating PV system because it considers real-world environmental factors.

Variable Step Size Maximum Power Point Tracker Using a Single Variable for Stand-alone Battery Storage PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.218-227
    • /
    • 2011
  • The subject of variable step size maximum power point tracking (MPPT) algorithms has been addressed in the literature. However, most of the addressed algorithms tune the variable step size according to two variables: the photovoltaic (PV) array voltage ($V_{PV}$) and the PV array current ($I_{PV}$). Therefore, both the PV array current and voltage have to be measured. Recently, maximum power point trackers that arc based on a single variable ($I_{PV}$ or $V_{PV}$) have received a great deal of attention due to their simplicity and ease of implementation, when compared to other tracking techniques. In this paper, two methods have been proposed to design a variable step size MPPT algorithm using only a single current sensor for stand-alone battery storage PV systems. These methods utilize only the relationship between the PV array measured current and the converter duty cycle (D) to automatically adapt the step change in the duty cycle to reach the maximum power point (MPP) of the PV array. Detailed analyses and flowcharts of the proposed methods are included. Moreover, a comparison has been made between the proposed methods to investigate their performance in the transient and steady states. Finally, experimental results with field programmable gate arrays (FPGAs) are presented to verify the performance of the proposed methods.

PV 어레이의 계통연계 모의를 위한 PSCAD 사용자 정의 모델 개발 (Development of PSCAD User-defined Model for the Simulation of a PV Array)

  • 안선주;최준호
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.134-139
    • /
    • 2011
  • Since large and small scale photovoltaic(PV) systems have been commercialized in many countries, it is necessary to assess the effects of PV systems on the electric power system. For this, the development of accurate simulation model of PV arrays is very important. PSCAD/EMTDC, a widely used simulation tool for analyzing the transient behavior of electrical apparatus and networks, does not have a standard model of a PV array. Therefore in order to simulate the PV array, users have to develop their own simulation model. However, the block-diagram-based model is very complicated, and it is hard to modify the model parameters. In this study, we develop the user-defined model of a PV array by using the Design Editor, which is provided by PSCAD program. The mathematical model of a PV array and the method to determine the parameters of nonlinear I-V equation are implemented in a Fortran code. The graphical user interface provides the users with easy and simple way to modify the PV array parameters and simulation conditions. In order to help the users, this model also provides the parameters of 10 commercial PV arrays.

출력편차의 통계학적 신호처리를 통한 태양광 발전 시스템의 고장 위치 진단 기술 (Fault Location Diagnosis Technique of Photovoltaic Power Systems through Statistic Signal Process of its Output Power Deviation)

  • 조현철
    • 전기학회논문지
    • /
    • 제63권11호
    • /
    • pp.1545-1550
    • /
    • 2014
  • Fault detection and diagnosis (FDD) of photovoltaic (PV) power systems is one of significant techniques for reducing economic loss due to abnormality occurred in PV modules. This paper presents a new FDD method against PV power systems by using statistical comparison. This comparative approach includes deviation signals between the outputs of two neighboring PV modules. We first define a binary hypothesis testing under such deviation and make use of a generalized likelihood ratio testing (GLRT) theory to derive its FDD algorithm. Additionally, a recursive computational mechanism for our proposed FDD algorithm is presented for improving a computational effectiveness in practice. We carry out a real-time experiment to test reliability of the proposed FDD algorithm by utilizing a lab based PV test-bed system.

A CONSIDERATION ON PHOTOVOLTAIC POWER GENERATION SYSTEMS

  • Sugisaka, Masanori;Nakanishi, Kiyokazu;Mitsuo, Noriaki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.468-468
    • /
    • 2000
  • In our laboratory, the control aspects are investigated in the photovoltaic power generation systems (PV systems). The PV system is very good for earth environment, but if it connects to power network system, many problems are raised (protection, voltage, harmonics etc.). In this paper, we present the result of the basic studies for the building of the PV system that amplifies the electric energy obtained from the solar cell. We consider electronic circuits in order to protect the PV system from power surge induced by lightning and also design an electronic circuit in order to detect defaults in the power network system. We would like to integrate these circuits into the PV system by considering its control equipment build by 8-bit microcomputer using various control theory (fuzzy, neural network etc.).

  • PDF

Novel Islanding Detection Method for Distributed PV Systems with Multi-Inverters

  • Cao, Dufeng;Wang, Yi;Sun, Zhenao;Wang, Yibo;Xu, Honghua
    • Journal of Power Electronics
    • /
    • 제16권3호
    • /
    • pp.1141-1151
    • /
    • 2016
  • This study proposes a novel islanding detection method for distributed photovoltaic (PV) systems with multi-inverters based on a combination of the power line carrier communication and Sandia frequency shift islanding detection methods. A parameter design method is provided for the novel scheme. On the basis of the designed parameters, the effect of frequency measurement errors and grid line impedance on the islanding detection performance of PV systems is analyzed. Experimental results show that the theoretical analysis is correct and that the novel method with the designed parameters has little effect on the power quality of the inverter output current. Non-detection zones are not observed, and a high degree of reliability is achieved. Moreover, the proposed islanding detection method is suitable for distributed PV systems with multi-inverters.