• Title/Summary/Keyword: PV Output Simulation

Search Result 140, Processing Time 0.024 seconds

Bus Voltage Regulation of DC Home Grid with PV-Battery-Ultracap (태양광-배터리-수퍼캡을 갖는 직류 홈 그리드의 버스 전압 제어)

  • Heryanto, Nur A.;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.467-468
    • /
    • 2019
  • This paper proposes an improved bus voltage regulation scheme in filter-based reference current generation of power management for DC home grid with photovoltaics (PV), battery, and ultracapacitor (ultracap) by using feedforward terms instead of the filter output to produce the ultracap reference current. Simulation results have proved the effectiveness of the proposed scheme.

  • PDF

Estimation of Output Power for PV Module with Damaged Bypass Diode using MATLAB (Matlab을 이용한 손상된 바이패스 다이오드가 포함된 PV 모듈의 출력 추정)

  • Shin, Woogyun;Go, Seokhwan;Ju, Youngchul;Chang, Hyosik;Kang, Gihwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.63-71
    • /
    • 2016
  • Installed PV module in field is affected by shading caused by various field environmental factors. Bypass diodes are installed in PV module for preventing a power loss and degradation of PV module by shading. But, Bypass diode is easily damaged by surge voltage and has often initial a defect. This paper propose the electric characteristic variation and the power prediction of PV module with damaged bypass diode. Firstly, the resistance for normal bypass diode and damaged bypass diode of resistance was measured by changing the current. When the current increases, the resistance of normal bypass diode is almost constant but the resistance of damaged bypass diode increases. Next, To estimate power of PV module by damaged bypass diode, the equation for the current is derived using solar cell equivalent circuit. Finally, the derived equation was simulated by using MatLab tools, was verified by comparing experimental data.

A Study on the Off-Grid Photovoltaic Generation System with Sequential Voltage System (순차전압시스템을 고려한 독립형 태양광 발전 시스템에 관한 연구)

  • Kim, Gu-Yong;Bae, Jun-Hyung;Kim, Jong-Hae
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.364-367
    • /
    • 2020
  • This paper presents the off-grid PV-ESS system of sequential voltage control method applied to OR logic gate. The conventional off-grid PV-ESS system with the low-voltage series connection has problems due to capacity expansion. To solve these problems, this paper proposes a noble PV-ESS system with high efficiency and low cost by applying sequential voltage control technique of the high-voltage series connection of analog circuit type. The input voltage of DC to AC inverter can be converted from the low-voltage by the combinations of series connection of the conventional cascaded 24V solar cell unit modules to the high-voltage of 384V in battery. The output voltage of the battery was 384V as the each input voltage of three phase DC to AC inverter, and the each output voltage of three phase 10kW DC to AC inverter is designed to be AC380V@60Hz as the line to line rms voltage value. To prove the validity of the theoretical analysis by PSIM simulation, the operating characteristics of sequential voltage control system with OR logic gate were confirmed through experiment results.

Modelling of I-V Characteristics of PV module with resistance variation (PV 모듈의 손실 저항 성분을 고려한 I-V 출력 모델링에 관한 연구)

  • Hong, Jong-Kyuong;Jung, Tae-Hee;Ryu, Se-Hwan;Won, Chang-Sub;Kang, Gi-Hwan;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.177-179
    • /
    • 2008
  • This paper, we proposed the theoretical model which includes series resistance $R_s$ and shunt resistance $R_{sh}$ of single-crystalline PV module and used numerical method based on physics. Series resistance $R_s$ was derived from approach for p-n junction diode instead of established form obtained from the simulator with irradiance changes. Electrical output characteristics for PV modules to count the effect of $R_s$ were then studied. Finally simulation results were compared to experimental data leading to good agreement.

  • PDF

Comparison of MPPT Control Method Characteristic for Stand-alone PV System (독립형 태양광 발전시스템의 MPPT 제어기법 특성비교)

  • Lee, Yong-Sik;Kim, Nam-In;Jeong, Sung-Won;Gim, Jae-Hyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.75-79
    • /
    • 2012
  • Maximum power point tracking(MPPT) techniques are used in photovoltaic systems to maximize the PV array output power by tracking continuously the maximum power point which depends on panels temperature and on irradiance conditions. This paper proposes a variable step size MPPT algorithm which can improve the MPPT speed and accuracy. Depending on insolation and temperature, the MPPT controller gives optimized step size. The effectiveness of the proposed system is verified thorough PSIM simulation and experiments on a 50[W] prototype. The experimental results confirm that the PV power of the improved P&O method is higher than that of the traditional P&O method.

Flyback Inverter Using Voltage Sensorless MPPT for Photovoltaic AC Modules

  • Ryu, Dong-Kyun;Choi, Bong-Yeon;Lee, Soon-Ryung;Kim, Young-Ho;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1293-1302
    • /
    • 2014
  • A flyback inverter using voltage sensorless maximum power point tracking (MPPT) for photovoltaic (PV) AC modules is presented. PV AC modules for a power rating from 150 W to 300 W are generally required for their small size and low price because of the installation on the back side of PV modules. In the conventional MPPT technique for PV AC modules, sensors for detecting PV voltage and PV current are required to calculate the PV output power. However, system size and cost increase when the voltage sensor and current sensor are used because of the addition of the auxiliary circuit for the sensors. The proposed method uses only the current sensor to track the MPP point. Therefore, the proposed control method overcomes drawbacks of the conventional control method. Theoretical analysis, simulation, and experiment are performed to verify the proposed control method.

The PV MPPT & Charge and Discharge Algorithm for the Battery Included Solar Cell Applications (배터리 내장형 초소형 태양광 장치용 PV MPPT 및 충방전 제어 알고리즘)

  • Kim, Seung-Min;Park, Bong-Hee;Choi, Ju-Yeop;Choy, Ick;Lee, Sang-Chul;Lae, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.69-75
    • /
    • 2013
  • To increase the efficiency of the photovoltaic, almost photovoltaic appliances are controlled by Maximum Power Point Tracking(MPPT). Existing most of the PV MPPT techniques have used power which multiplies sensed output current and voltage of the solar cell. However, these algorithms are unnecessarily complicated and too expensive for small and compact system. The other hand, the proposed MPPT technique is only one sensing of the MPPT converter's output current, so there is no need to insert another sensors of battery side. Therefore, this algorithm is simpler compared to the traditional approach and is suitable for low power solar system. Further, the novel proper charge/discharge algorithm for the battery with PV MPPT is developed. In this algorithm, there is CC battery charge mode and load discharge mode of the PV cell & battery dual. Also we design current control to regulate allowable current during the battery charging. The proposed algorithm will be applicable to battery included solar cell applications like solar lantern and solar remote control car. Finally, the proposed method has been verified with computer simulation.

Solar Cell Arrays Connection of Large Scale PV System (대규모 PV시스템의 태양전지 어레이 구성법)

  • Yu, Gwon-Jong;Song, Jin-Soo;Ro, Myong-Gun;Sung, Se-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.326-328
    • /
    • 1996
  • The 10kW or 1MW model of a photovoltaic array written in PSPICE is presented in this paper. A problem with this large scale centralized photovoltaic system is the decrease of power due to the resistance of cable connecting individual subarray with inverter. In this paper, we analyzed the relationship between the resistance of cable and subarray output power of 1MW photovoltaic system by the PSPICE modeling. As a result of simulation, we can proved that photovoltaic array output power is limitted by the resistance of cable.

  • PDF

Optimization technique of POS MPPT operational characteristics for grid-connected PV generation system (계통 연계형 태양광발전시스템을 위한 POS MPPT 운전특성 최적화 기법)

  • Park, Sang-Soo;Kim, Sang-Yong;Jang, Seong-Jae;Kim, Gyeong-Hun;Seo, Hyo-Ryong;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1064_1065
    • /
    • 2009
  • PV (Photovoltaic) power generation system has been widely studied as a clean and renewable power source. Tracking the MPP (maximum power point) of a PV array is usually an essential part of a PV system. This paper describes POS (Photovoltaic Output Sensorless) MPPT method and optimization technique of its operational characteristics for grid-connected PV generation system. A DC-DC converter has been used to step-up the PV voltage and DC-AC converter has been used for connecting the system to the grid. Optimization technique has been implemented to optimize the current and voltage controller gain parameters and duty ratio increment of DC-DC converter. Simulation results reveal that the proposed control has better response.

  • PDF

Active Frequency Drift Positive Feedback Method for Anti-islanding applied Digital Phase-Locked-Loop (Digital PLL을 이용한 Active Frequency Drift Positive Feedback에 관한 연구)

  • Lee, K.O.;Choi, J.Y.;Choy, I.;Jung, Y.S.;Yu, G.Y.;Song, S.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.250-254
    • /
    • 2007
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

  • PDF