• 제목/요약/키워드: PULSE

검색결과 10,423건 처리시간 0.036초

맥 Energy와 사상체질병증의 연계 연구 (A Study on the Correlation between Pulse Energy and Sasang Constitutional Syndromes)

  • 김달래;김선형
    • 대한한의학회지
    • /
    • 제30권1호
    • /
    • pp.26-39
    • /
    • 2009
  • Objectives: Pulse energy values recorded with an add-pres sure-type pulse apparatus were correlated with Sasang constitutional syndromes in order to match pulse energy values with Sasang prescriptions. Methods: The pulse energy values were measured with Daeyo Pulse Apparatus at the Gwan pulse point of both wrists. Prescriptions were divided into two major categories of interior syndromes or exterior syndromes, and categorized according to major component herbs specific to each of the four Sasang constitutions, and the relationship between the pulse energy and each groups divided by their prescription was studied. Results: About 10% of all people had nonmal pulse energy values. 10% had values over normal range, and $70\sim80%$ had lower values than normal. The normal range of pulse energy was regarded as being between 450 and 700. Conclusions: 1. For patients of the Soeum constitution, prescriptions without Panax ginseng is suitable for patients with high pulse energy, and prescriptions containing Panax ginseng are suitable for patients who have lower pulse energy. 2. All prescriptions for the Soyang constitution containing Rehmannia radix preparata or Comus officinalis are suitable for patients who have lower pulse energy, and prescriptions containing Rehmannia radix or Gypsum fibrosum are applicable to patients with pulse energy values higher than normal. 3. Most prescriptions for the Taeum constitution containing Semen coicis or Semen castaneae are suitable for patients with lower pulse energy, and prescriptions containing Radix puerariae or Radix et rhizoma rhei can be prescribed for patients who have lower pulse energy levels. 4. The Taeyang constitutional prescription Ogapijangcuck-tang is suitable for patients who have higher pulse energy levels and Mihudeungsikjang-tang is better for patients with lower than normal pulse values. As described above, the pulse energy level of each patient can be matched with a specific Sasang constitutional prescription. If this relationship is taken into consideration with other conventional symptoms, it can be helpful in diagnosis, improving efficacy of treatment, and be used as objective evidence.

  • PDF

식사가 정상인의 맥에 미치는 영향 분석 (Effect of Taking Meal on Pulse Diagnosis in Healthy Subjects)

  • 이유정;이전;이혜정;최은지;김종열
    • 동의생리병리학회지
    • /
    • 제21권6호
    • /
    • pp.1670-1675
    • /
    • 2007
  • The pulse diagnosis studies reported to date has mainly been performed to clinically reveal the pulse wave characteristics according to the specific diseases, whereas no attempts have been made to study the effects on the pulse wave characteristics of the daily activities such as taking meals, exercise, and sleep, etc. This work reports the effect of feeding stimulus on the healthy subjects on the pulse wave pattern which has quantitatively been analyzed using the objective model for the pulse diagnosis in oriental medicine. The pulse waves right before/after the meal and 30 minutes after the meal were measured using the pulse analyzing equipment (3D-Mac, Daeyo Medi, Korea) and at the same time oriental medicine doctors' diagnoses were given. The pulse parameters obtained from the equipment and clinical records on the subjects were statistically processed and the variables showing statistically significant differences were analyzed. The results indicate that the pulse pressure, the pulse rate, and the respiratory rate increase while the blood pressure decreases after the meal. For the floating/sinking and the deficient/excess coefficients characterizing the pulse states described in the oriental medicine, the floating/sinking coefficients were observed to decrease whereas the deficiency/excess coefficients increase after the meal. The results indicates that besides the standard bio-indicators like blood pressure and respiratory rate, etc., the pulse wave characterization in terms of the pulse classifications in the oriental medicine using the floating/sinking, deficient/excess pulse states provide an important piece of biomedical information.

5단계 가압에 대한 맥파 변화 분석에 의한 맥 패턴 분류와 부침맥(浮沈脈) 연구 (A study on floating and sinking pulse by classification of pulse pattern through analysis of P-H volume-curve at 5 applied pressure levels)

  • 권선민;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제27권1호
    • /
    • pp.13-22
    • /
    • 2010
  • Objectives: The information on the depth where pulse wave appears is as important as pulse waveform. The aim of this study was to classify pulse pattern using pressure-height(P-H) volume-curve by 5 applied pressure levels to find out the information on the depth of pulse and interpret the floating & sinking pulse in oriental medical pulse diagnosis. Methods: We used 3 dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea), which measures radial pulse waveforms noninvasively by way of tonometric method at 5 applied pressure levels, and shows P-H volume-curves by applied pressure. 448 subjects were enrolled, pulse waveforms were measured and the P-H volume-curves were gained on the three locations of Chon, Kwan, and Cheok. Results: Gained P-H volume curves were classified into 3 types ; increase type, decrease type, and increase-decrease type. Increase-decrease type appeared more often on Chon and Kwan, while increase type appeared more often on Cheok. In a few cases, decrease-type appeared on Chon and Kawn, however it never appeared on Cheok. Conclusions: Through the classification of pulse by P-H volume-curve, we gained the information on the depth of pulse. We speculate the decrease type as floating pulse, the increase-decrease type as middle pulse, and the increase type as sinking pulse in oriental medical pulse diagnosis. After more researches on P-H volume-curve by applied pressure, the P-H volume-curve may be used as an important factor for pulse diagnosis.

삭맥(數脈)의 허실(虛實)과 미발현(未發現) (A Study on the Deficiency-excess Pattern of the Rapid Pulse)

  • 홍승민;박휘은
    • 한국한의학연구원논문집
    • /
    • 제16권3호
    • /
    • pp.33-44
    • /
    • 2010
  • Pulse diagnosis is considered one of the most important diagnostic methods in traditional Korean medicine. Nonetheless, there have been troubles of using pulse diagnosis practically, for the lack of its differential standards and standardized terminology. Rapid pulse belongs to the several traditional pulse types. Rapid pulse was first mentioned in the chinese medical book Haungdineijin that matched it to the fever as well as yang in the human body. Meanwhile, chinese doctors in Ming Ching dynasty of China suggested that rapid pulse meant more of the yin, cold-related reaction than yang and fever. In this study, we organized the past arguments of the rapid pulse and went back tracking what biological activities could be possibly linked to the rapid pulse. Thus, we figured out that the inflammatory mechanism has a close connection with the rapid pulse. The definition of the rapid pulse in Haungdineijin was indicating the acute inflammatory response, while in Ming Ching dynasty, it indicated the chronic inflammation. This is the deficiency-excess pattern of the rapid pulse. Furthermore, we discussed the nonexpression pattern of the rapid pulse which could be happened in case of the heat stroke, etc.

"황제내경"에 나타난 침자 전후의 맥진 (Pulse diagnosis procedure before and after the acupuncture in Hwangjenaekyung)

  • 배성철;신승훈;김기왕
    • 대한한의학원전학회지
    • /
    • 제24권3호
    • /
    • pp.15-25
    • /
    • 2011
  • The acupuncture procedures in Hwangjenaekyung (黃帝內經) was different to modern ones in many aspects. Especially, the role of pulse diagnosis in acupuncture was totally different and the pulse diagnosis was essential part in acupuncture therapy in Hwangjenaekyung era. We found four noteworthy features on the pulse diagnosis before and after acupuncture in Hwangjenaekyung : (1) Pulse diagnosis was a mandatory process in acupuncture (2) Doctors who used pulse diagnosis in 12 meridians (十二經脈遍診脈法), pulse diagnosis in 9 points of 3 body parts (三部九候脈法), and comparative pulse diagnosis between radial artery and carotid artery (人迎寸口對比脈法) followed the former rule ((1)). (3) The major pulse features to detect before and after acupuncture were conversion between the vacuous pulse (虛脈) and the replete pulse (實脈), and conversion between slippery pulse (滑脈) and rough pulse (澁脈). (4) Deukki (得氣, Deqi) was synonym of Kiji (氣至), and it referred to the changes of arterial pulse, not the sensation followed by acupuncture manipulation.

나선형 블룸라인 PFL을 이용한 50 ns 펄스폭의 고전압 펄스 발생 (Generation of a High Voltage Pulse of 50 ns Pulse Duration using a Helical Blumlein Pulse Forming Line)

  • 노영수;진윤식
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.786-791
    • /
    • 2013
  • A high voltage pulse generator based on the Blumlein pulse forming line (PFL) was fabricated to produce a voltage pulse whose peak value is ~300 kV and pulse duration is ~50 ns. Three cylindrical electrodes, such as inner, middle, and outer electrodes, are concentrically placed to make a compact PFL. To increase the pulse duration of the output pulse without any change of the size of the generator, the middle electrode is replaced by a helical strip electrode. To determine the radius of the helical electrode, the impedance of the helical Blumlein PFL is calculated using an approximate formula where the dispersive property of the helical Blumlein PFL is not considered. The dependence of the impedance on the frequency is computed by a commercial program. The number of turns in the helical electrode is decided to provide a demanded pulse duration. The experimental result shows that the helical Blumlein PFL is capable of making a high voltage pulse of ~50 ns pulse duration.

맥솔(脈率)과 심박변이도(心搏變移度)의 상관성(相關性) 연구(硏究) (Correlation between Pulse-respiration Ratio and Heart Rate Variability)

  • 양동훈;박영배
    • 대한한의진단학회지
    • /
    • 제10권2호
    • /
    • pp.104-120
    • /
    • 2006
  • Background : Pulse-respiration ratio has been used for estimating subject's status in oriental medicine. Pulse and respiration is strongly associated with autonomic nerve system. But there is no research about correlation between pulse-respiration ratio and autonomic nerve system. Objectives : We performed this study to know correlation between pulse-respiration ratio and HRV(heart rate variability) that shows autonomic nerve system status well and to clarify clinical meaning of pulse-respiration ratio. Methods : After subject's 10 minutes rest, we measured subject's ECG, respiration pattern and HRV. In this research, subject's number is 95(Male 50/Female 45). We calculated pulse-respiration ratio from ECG and respiration pattern. Then, we analyzed correlation between pulse-respiration ratio and HRV parameters in all subjects, 2 group divided by Wan-Maek(P-R ratio 4.28). We tried to compare HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek group. Correlation analysis between pulse-respiration Ratio and Pulse rate, respiration rate is performed. Finally correlation analysis between Respiration and HRV parameters in all subjects, 2 group divided by Wan-Maek(4.28) is studied. Results : 1. Mean pulse-respiration is 4.10${\pm}$0.67, Mean pulse rate is 68.06${\pm}$7.82bpm, Mean respiration rate is 16.81${\pm}$2.72 times per minute in all subjects. 2. Correlation analysis between pulse-respiration ratio and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm(correlation coefficient 0.306, p= 0.018), lnHF (0.308, p=0.002) is significantly correlated with pulse-respiration ratio. 3. Comparison of HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek Group is not significant. 4. Pulse-respiration ratio is more affected by respiration rate(correlation coefficient-0.17, p=0.000) than pulse rate (correlation coefficient 0.396, p=0.000). 5. Correlation analysis between respiration rate and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm (correlation coefficient -0.327, p=0.011), LF/HF(0.346, p=0.007), lnHF (-0.355, p=0.006) are significantly correlated with respiration rate. Conclusion : Pulse-respiration ratio and parasympathetic index has positive correlation. The closer Wan-Maek, The higher parasympathetic index in low pulse-respiration ratio group. Respiration rate is more related with pulse-respiration ratio than pulse rate. Respiration is negatively correlated with autonomic parameters. And the slower respiration, the higher parasympathetic index in low pulse-respiration ratio group.

  • PDF

고혈압 환자의 맥상 연구 (A Study on the Pulse Wave Parameter in Hypertension Patients)

  • 정현정
    • 대한한의진단학회지
    • /
    • 제18권2호
    • /
    • pp.51-62
    • /
    • 2014
  • Objectives The purpose of this study was to determine whether a pulse analyzer was useful to characterize the variables of pulse wave of hypertension (HT), compared with those of normal blood pressure group (NP). Methods The subjects were 22,646 who worked at car manufacturing factory. The pulse wave variables and pulse types measured in Guan by DMP 1000. Results In the main and secondary pulse type, there were significant differences between HT and NP. Whereas, in the field of pulse wave variables, no specific differences were between HT and NP. Conclusion Although pulse wave variables were not statistically significant, pulse analyzer might have reliable diagnostic sensitivity between hypertension and non-hypertension population.

IGBT 직렬구동에 의한 60KV 펄스 전원장치 개발 (Development of 60KV Pulsed Power Supply using IGBT Stacks)

  • Ryoo, Hong-Je;Kim, Jong-Soo;Rim, Geun-Hie;Goussev, G.I.;Sytykh, D.
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.88-99
    • /
    • 2007
  • In this paper, a novel new pulse power generator based on IGBT stacks is proposed for pulse power application. Because it can generate up to 60kV pulse output voltage without any step- up transformer or pulse forming network, it has advantages of fast rising time, easiness of pulse width variation and rectangular pulse shape. Proposed scheme consists of series connected 9 power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. To reduce component for gate power supply, a simple and robust gate drive circuit is proposed. For gating signal synchronization, full bridge invertor and pulse transformer generates on-off signals of IGBT gating with gate power simultaneously and it has very good characteristics of short circuit protection.

Marx 펄스발생기를 응용한 소형 고전압 급준 펄스 발생장치 (Fast Rise Time High Voltage Pulse Generator Applying The Marx Generator)

  • 박승록;정석환;김진규;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권2호
    • /
    • pp.72-78
    • /
    • 2001
  • A compact size high voltage pulse generator with nanosecond rise time has been designed and investigated experimentally. The inductance of a pulse generator can be reduced by fixing the Marx generator and pulse forming network components into a single cylindrical unit. As a result, nanosecond rise time about $8{\sim}10[ns]$ and pulse width of several hundred [ns] can be obtained from a modified Marx pulse generator. And parametric studies showed that the rise time of the output pulse was depended little on the change of the load resistance and the charging capacitance while, the pulse width of the output pulse was depended greatly upon the change of the load resistance and the charging capacitance. The theoretical showed the possibility to design the laboratory-size pulse generator very fast rising time and a proper pulse width by minimizing stray inductance and varying resistance and capacitance.

  • PDF