Browse > Article

A Study on the Pulse Wave Parameter in Hypertension Patients  

Jung, Hyun-Jung (Department of Diagnostics College of Korean Medicine, Deagu Hanny University)
Publication Information
The Journal of the Society of Korean Medicine Diagnostics / v.18, no.2, 2014 , pp. 51-62 More about this Journal
Abstract
Objectives The purpose of this study was to determine whether a pulse analyzer was useful to characterize the variables of pulse wave of hypertension (HT), compared with those of normal blood pressure group (NP). Methods The subjects were 22,646 who worked at car manufacturing factory. The pulse wave variables and pulse types measured in Guan by DMP 1000. Results In the main and secondary pulse type, there were significant differences between HT and NP. Whereas, in the field of pulse wave variables, no specific differences were between HT and NP. Conclusion Although pulse wave variables were not statistically significant, pulse analyzer might have reliable diagnostic sensitivity between hypertension and non-hypertension population.
Keywords
Hypertension; Pulse wave; Pulse type; Pulse analyzer;
Citations & Related Records
Times Cited By KSCI : 8  (Citation Analysis)
연도 인용수 순위
1 Choi SD, Kim MS, An MC, Choi YG, Kim GY, Park DH, et al. Achievement of 3-D Pulse Waves of Pulse Diagnostic Apparatus by using Multi-Hall Devices. Journal of the Korean Magnetics Society. 2006;16(4):216-20.   DOI
2 Lee YJ, Lee J, Kim JY. Suggestion on an Innovative Pulse Diagnosis System based on Technical Trend Analysis. Korean journal of oriental physiology & pathology. 2009;23(3):174-9.
3 Park YB, Lee HJ, Huh Y. The development of pulse diagnostic apparatus enable to gain multi-information and it's clinical significance. Journal of Korean Oriental Med. 1995;16(1):499-504.
4 Kim EG, Heo H, Nam KC, Huh Y. 15 channel tonometric radial pulse measurement system using air cuff pressure. Journal of information and control system. 2008:205-6.
5 Shin YJ, Kim YB, Youn SH. A clinical study of atopic dermatitis patients as measured by pulse diagnostic apparatus. Journal of Korean Oriental Medical Ophthalmology & Otolaryngology & Dermatology. 2008;21:112-9.
6 Lee YJ, Lee HJ, Lee J, Kang JH, Lee SW, Kim JY. The effect of the BMI on the automatic pulse diagnosis on Korean traditional medicine. Journal of the Korean Magnetics society. 2007;Summer: 1904-5.
7 Ha IY, Youn YC, Youn DH, Choi CH, Lee YS, Lim SI, et al. Comparative study of speed, size and depth of pulse on the traditional pulse diagnosis and pulse analyzer. Korean Journal of Acupuncture. 2011;28(1):23-37.
8 Song MS, Park HS, Kim OY, Kim BS, Yang DC, Choi CH. Relationship of Inyoung-Chongu Pulse, BMI and Sasang constitution using pulse diagnosis device. Korean J. Oriental Physiology & Pathology. 2011;25:399-440.
9 Choi YS, Kim KY, Hwang SY, Kim JY, Lee SW, Kim HH et al. Charateristic of the pulse wave in hypertension using pulse analyzer with array piezoresistive sensor. Journal of Meridian & Acupoint. 2007;24:105-16.
10 Ha HJ, Cho MY, Yun JM, Jun KS, Park SJ, Shin SH. Characteristics of Pulse Waves in Various Age Categories and Applicability of Pulse Wave to Metabolic Syndromes Using Pen-Type Piezoresistive Sensor. Korean J. Oriental Int. Med. 2012:33(3);257-71.
11 唐亞平, 侯恩存, 戴芳. 體型胖瘦對脈象影響的 硏究. 中國中醫基礎醫学杂誌 2009;15:387-8.
12 唐亞平, 楊宏寶, 樊新榮, 戴芳, 朱文鋒. 沈脈與. 生理性因素的相關性研究. 遼寧中醫雜誌 2007; 34:1046-7.
13 唐亞平, 樊新榮, 楊力強, 戴芳, 朱文鋒. 浮脈與 .生理性因素的相關性的研究. 時珍國醫國藥 2007;18:2818-9.
14 Shin SH, Rhim HW, Park YJ, Park YB. A study of the cardiovascular aging effect on the pulse shape. The Journal of The Korea Institute Of Oriental Medical Diagnostics. 2005;9(1) :59-68.
15 Korea Health Statistics 2011 : Korea National Health and Nutrition Examination Survey (KNHANES V-2)
16 배성인. 최운영. 맥진법의 의사학적 소고. 대한한의학경락진단학회지. 2003;2:114-28.
17 Kim HH, Lee J, Kim JW, Kim JY. Proposal for pulse diagnosis positions (Chon-Kwan-Chuk) for pulse analyzer based on literature review and anthropometry. J Korean Oriental Med. 2007; 28(3):13-22.
18 陳可. 高血壓弦脈的血液動力學分析, 中華內科雜誌. 1962;19:638-41.
19 趙思儉. 高血壓 88例 脈象圖分析. 天進醫學. 1982;39(3):34-128.
20 Lee YJ, Lee HJ, Lee SW, Kim JY. The Process of Clinical Test on Pulse Analyzer. The international conference on oriental medicine. 2005:62-5.
21 Shin SS, Rhim HW, Park YJ, Park YB. A Study of the Cardiovascular Aging Effect on the Pulse Shape. The Journal of The Korea Institue of Oriental Medical Diagnostics. 2005;9(1):59-68.
22 Nichols W, O'Rourke MF. McDonald's blood flow in arteries. London: Arnold;1998./Nurnberger J, Keflioglu-Scheiber A,Opazo Saez AM, Wenzel RR, Philipp T,Schafers RF. Augmentation index is associated with cardiovascular risk. J Hypertension 2002;20:2407-14.
23 Weber T, Auer J, O'Rourke MF, Kvas E, Lassnig E, Berent R, Eber B. Arterial stiffness, wave reflections, and the risk of coronary artery disease. Circulation 2004;109:184-9.   DOI   ScienceOn
24 London GM, Blacher J, Pannier B, Guerin AP, Marchais SJ, Safar ME.Arterial wave reflections and survival in end-stage renal failure. Hypertension 2001;38:434-8.   DOI   ScienceOn
25 이봉교, 박영배, 김태희. 한방진단학. 6판. 서울: 성보사. 2004:161-3.
26 임양근. 진단학아틀라스맥진. 서울:정담. 2003: 11-12, 49-50, 66-76, 113-205.
27 朱文鋒. 中醫脈診與鑑別診斷學. 北京:人民衛生出版社. 1999:110-3.
28 張洪義. 中醫臨床診斷全書. 中國天津:天津科學技術出版社. 2002:46-9.
29 채인식. 한방임상학. 서울:의성당. 2005:230-45.
30 陳德奎. 弦滑脈的血液動力學分析. 中西醫綜合雜誌. 1983;3(4):232.
31 김경철, 강희정, 맥의공학연구회. 맥의공학 연구 방법론. 경기도 안산:대요메디. 2008:83-6.
32 張保榮, 黃建國. 弦脈脈象臨床觀察報告. 湖北中醫雜誌. 2001;3:19-20.
33 Ha YJ, Choi MY, Yun JM, Jun KS, Park SJ, Shin SH. Characteristics of Pulse Waves in Various Age Categories and Applicability of Pulse Wave to Metabolic Syndrome Using Pen-type Piezoresistive Sensor. Korean J. Orient. Int. Med. 2012:33(3): 257-71.
34 이봉교. 맥진 현대화의 이론과 실제. 서울:성보사. 2003:212-40.
35 Kang HJ, Kwon YS, Kim DL, Kim KC, Yim YK. A study on wiry pulse in hypertensive patients analyzed at 5 levels of applied pressure using 3 dimensional pulse imaging analyzer. Journal of Meridian & Acupoint. 2010;27(1):1-12.