• Title/Summary/Keyword: PULSE

Search Result 10,459, Processing Time 0.034 seconds

Research on the Imminent Labor Pulse - A Focus on Pulse Theory and Clinical Practicality - (임산(臨産) 이경맥(離經脈)에 대한 연구 - 맥리(脈理)와 임상활용을 중심으로 -)

  • Lyu, Jeong-Ah;Baik, Sang-Ryong;Jeong, Chang-Hyun
    • Journal of Korean Medical classics
    • /
    • v.26 no.1
    • /
    • pp.131-150
    • /
    • 2013
  • Subject : The Imminent Labor Pulse(臨産 離經脈, extra-meridian pulse approaching labor) is one of many practical clinical knowledges, unique to Traditional Korean(Eastern) Medicine. Objective : This research explores the origin and change of perception on the subject throughout history, with objective to sort out practical knowledge applicable in the clinic of today. Also, it draws clinical meaning of pulse diagnosis according to the physiological theories, and suggests directions for future clinical researches. Method : First, the Imminent Labor Pulse was examined based on major publications such as the "Nanjing", "Maijing" and theories of major doctors. Second, this previous study was examined through clinical observation research. Third, further research was carried out on pulse theory according to the Traditional Medical theories. Fourth, their clinical practicality and points of further research were sorted out. These points need to be examined through additional clinical research. Conclusion : The following conclusions could be drawn from study of the Imminent Labor Pulse. From the Imminent Labor Pulse which indicated the beginning of the first period of labor in the "Maijing", it developed into trying to grasp the beginning of the second period of labor which is the actual time of labor, through "Zhubingyuanhoulun" and "Shizaizhifang". By Xueji, another pulse that could be felt on the middle finger of the mother had been discovered. The middle finger is where the Pericardium Meridian flows. The child's connection to the uterus becomes disconnected on the first period, but that with the Pericardium meridian which provides blood meridian to the Taichongmai of the child continues throughout labor until the umbilicus chord is cut. Therefore, this middle finger pulse could serve as showing the heart condition of the mother and child during labor. The time of its appearance and disappearance, and their correlation with the child's heartbeat need to be clinically examined.

Oriental Pulse Diagnostic Apparatus with an emphasis on sense on fingers (수지부 감각정보에 중점을 둔 한의학적 전자 맥진 시스템에 대한 고찰)

  • Kim, Byoung-Chul;Chae, Han
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.112-120
    • /
    • 2008
  • This study aims to develop a system for diagnosing pulse and disease conditions based on oriental medical classics to collect objective quantitative information in the traditional pulse examination environment that uses fingers. For this purpose, the study suggested a thimble-type sensor unit as the most appropriate pulse analyzer and proposed a traditional method to measure the pulse pressure wave on the spots of cheok, gwan and chon by installing the pulse analyzer on the forefinger, middle finger and medical finger. Then, it was interpretively found that this pulse analyzer enables us to objectively recognize 28 pulses defined in Oriental medical classics including the yukjo pulse, described as the buchimjisak-heosil pulse, and the hong, yoo, hyeok and san pulses. Finally, the study proposed a method to extract key parameters essential to pulse condition diagnosis from the pulse pressure wave measured by this pulse analyzer.

  • PDF

Propagation and Crosstalk Characteristic Analysis of Pulse Shaped Signals on the Coupled Microstrip Lines (결합 마이크로스트립 선로상의 펄스형태 신호의 전파 및 누화 특성 해석)

  • Park, Sun-Keun;Kim, Nam;Rhee, Sung-Yup;Jang, Woo-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.5
    • /
    • pp.516-524
    • /
    • 1997
  • The propagation properties of various pulse signal types(square pulse, Gaussian pulse, trapezoid pulse, RF pulse) on coupled microstrip lines are investigated. Numerical integration technique which has its accuracy and is easily simulated, is used to obtain the time domain response of pulse signals. Frequency-dependent characteristics of coupled microstrip line is obtained using Jansen's approximate equation. The propagation properties of pulse signal on coupled microstrip lines is analyzed regarding to its geometric structure (relative permittivity ${varepsilon}_r$ substrate height h, strip width w of the microstrip line) and pulse width ${\tau}$ of signal pulse. The simulation results show that space between two lines is very significant parameter in pulse distortion in comparison of any other parameters. The results of this paper are compatible to the trade-off determination of relative permittivity, substrate height, strip width and pulse width of signal pulse when a design of MIC and MMIC is necessary.

  • PDF

The Effects of Sa-Am Spleen-tonifying Acupuncture on Radial Pulse in Healthy Human Subjects (비정격(脾正格) 자침이 정상 성인 맥파(脈波) 변화에 미치는 영향)

  • Yoon, Kwang Sik;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.1-14
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the effects of Sa-Am spleen-tonifying acupuncture on radial pulse in healthy human subjects. Methods : Forty healthy human subjects participated in this study, divided into acupuncture group and control group. Radial pulse was measured by 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after and 60 minutes after acupuncture in the acupuncture group. The subjects in the control group didn't received acupuncture but took a rest and then the radial pulse was measured at the same time points as the acupuncture group. The parameters were analyzed by gender, measuring location, and measuring time point. However the time related parameters exceptionally were analyzed without distinction of measuring location. Results : 1. T, variance of period, T2/T, T4/T, (T-T4)/T, T4/(T-T4), and W significantly changed after acupuncture. 2. Pressure, amplitude of H1, amplitude of H2, Amplitude of H4 and pulse energy significantly changed after acupuncture. 3. Pulse area, systolic pulse area and diastolic pulse area significantly changed after acupuncture. 4. Elasticity, AIx and AIx/HR significantly changed after acupuncture. Conclusions : The effect of Sa-Am spleen-tonifying acupuncture in healthy human may be observed on time, amplitude, pulse area and augmentation index. Further studies on the effects of Sa-Am acupuncture using radial pulse are needed.

Embodiment of Spatially Arterial Pulse Diagnostic Apparatus using Array Multiple Hall Devices

  • Lee, Sang-Suk;Kim, Gi-Wang;Ahn, Myung-Cheon;Park, Young-Seok;Choi, Jong-Gu;Choi, Sang-Dae;Park, Dal-Ho;Hwang, Do-Guwn;Yoon, Hyung-Rho
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.721-726
    • /
    • 2007
  • The study relates to achievement and analysis of 3-dimensional spatial pulse wave archived by a spatially arterial pulse diagnostic apparatus (SAPDA), wherein a pulse sensing part array consists of multiple hall devices and is located over a skin contacting part which consists of a magnetic material. When a radially arterial pulse is transferred to the magnetic material, which is contacted skin that results in changes in a magnetic field of the lower part of the pulse sensing part array, the changes in a magnetic field can be detected by the commercial Hall semiconductor device of the pulse sensing part array. Finally, according to development of SAPDA, the 3-dimensionally arterial pulse waveform can be measured noninvasively by detecting the changes of the magnetic field.

The literature study on the individual characteristic factor by the interrogation of history taking and palpation (소증(素證)과 맥진(脈診)에서의 개체성(個體性) 관찰(觀察)에 대한 문헌적(文獻的) 고찰(考察))

  • Kim, Gyeong Cheol;Lee, Hae Woong
    • Journal of Korean Medical classics
    • /
    • v.27 no.3
    • /
    • pp.1-10
    • /
    • 2014
  • Objectives : For the excellent differentiation of syndromes, we study on the individual characteristic factor by the interrogation of history taking and palpation. Methods : To the subject of diagnosis special books and diagnostics textbook of korean medicine, we arrange the individual characteristic factor by the interrogation of history taking and palpation. Results : The interrogation of history taking on the individual characteristic factor was arranged dispositional symptoms and individual characteristic of syndromes. And the pulse taking and palpation on the individual characteristic factor was arranged the moderate person's pulse condition ; floating pulse, deep and sinking pulse, replete and forceful pulse, intermittent pulse, long pulse, slippery or smooth pulse, relaxed or loose pulse (浮沈實大長滑緩脈), six Yin and six Yang pulse (六陽脈, 六陰脈). Conclusions : As the results, the individual characteristic factor is very important item of the four methods of diagnosis and the differentiation of syndromes. And therefore, we have to divide the signs of individual characteristic factor and the signs of disease in the process on four methods of diagnosis and differentiation of syndromes.

A Study on the Microhole Machining Characteristics of the ${Al_2}{0_3}$ Ceramics using Excimer Laser (Excimer laser를 이용한 알루미나(${Al_2}{0_3}$) 세라믹의 미세구멍 가공 특성에 대한 연구)

  • 김병용;이건상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.1072-1075
    • /
    • 2001
  • $Al_2O_3$ ceramics are generally used as components in processing equipment, devices or machinery because it can perform some functions better than competing metals or polymers. Many of these applications rely on $Al_2O_3$ ceramics special electromagnetic properties, its relative chemical inertness, hardness, strength and its temperature capabilities. But $Al_2O_3$ ceramics are brittle materials, a fact that may cause problems and at the same time be helpful while machining with laser. This study described a basic study of the input parameters effect on the dimension of the microhole at the $Al_2O_3$ ceramics using Excimer laser. In the laser microhole machining of $Al_2O_3$ ceramics, major input parameters are pulse energy, pulse power, pulse frequency and pulse numbers. In conclusion, we can get a smaller microhole and diameter rate by an appropriate pulse energy, pulse frequency and pulse number.

  • PDF

Trichel Pulse in Negative DC Corona discharge and Its Electromagnetic Radiations

  • Zhang, Yu;Liu, Li-Juan;Miao, Jin-Song;Peng, Zu-Lin;Ouyang, Ji-Ting
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1174-1180
    • /
    • 2015
  • We investigate in this paper the radiated electromagnetic waves together with the discharge characteristics of Trichel pulse of negative DC corona discharge in air in pin-to-plate and wire-to-plate configurations. The feature of the current pulse and the frequency spectrum of the electromagnetic radiations were measured under various pressures and gas gaps. The results show that the repetition frequency and the amplitude of Trichel pulse current depend on the discharge conditions, but the rising time of the pulse relates only to the radius of needle or wire and keeps constant even if the other conditions (including the discharge current, the gas gap and the gas pressure) change. There exists the characterized spectrum of electromagnetic waves from negative corona discharge in Trichel pulse regime. These characterized radiations do not change their frequency at a given cathode geometry even if the averaged current, the gas gap or the air pressure changes, but the amplitude of radiations changes accordingly. The characterized electromagnetic radiations from Trichel pulse corona relate to the formation or the rising edge of current pulse. It confirms that the characterized radiations from Trichel pulse supply information of discharge system and provide a potential method for detecting charged targets.

Study on Pulse Simulator of Oriental Medicine for Objective Structured Clinical Examination (OSCE) (한의학 객관구조화진료시험(OSCE)을 위한 진맥 시뮬레이터 개념 연구)

  • Kim, Kyoung-Shin;Kim, Kyoung-Ho;Choi, Chan-Hun;Lee, Soo-Jin;Kim, Byoung-Soo
    • The Journal of Korean Medicine
    • /
    • v.32 no.1
    • /
    • pp.1-11
    • /
    • 2011
  • Objectives: The aim of this study was to examine the controversial issues about objective structured clinical examination (OSCE) of pulse diagnosis and investigate the objectification of traditional Korean medicine and technical feasibility of pulse simulation through the suggestion of a pulse simulator. Methods: The concept, validity and reliability of OSCE and the current situation of medical simulation was described. The actual level and problems on the simulator development was presented through haptics and tactile technology in order to compose a pulse simulator for OSCE. Results: The pulse wave system of a pulse simulator should materialize through haptic technology and the classification of the differences between tactile sensation and tactile quality is essential for the development of the relevant pulse simulator for OSCE in traditional Korean medicine. Conclusions: The introduction and controversial issues of OSCE and methodology of pulse wave reappearance system are proposed for the objectification of Traditional Korean Medicine and the development of clinical technology.

Generation and Characteristics of Exponential Pulse Shaping Functions using Chebychev Identity Equation and Bessel Coefficients (Chebychev 항등식과 Bessel 계수를 이용한 지수펄스모형함수 생성 및 특성)

  • Lee, Jeong-Jae;Park, Sun-Kwang
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.1
    • /
    • pp.60-65
    • /
    • 2009
  • In this paper, we propose a new exponential pulse shaping function based on Chebychev identity equation and Bessel coefficients. The proposed pulse shaping function can produce various pulses with the different characteristics in the time and frequency domain by changing its two parameters. By differentiating the exponential pulse shaping function, we obtain new different pulse functions, in which the even order derivatives of the exponential pulse shaping function are orthogonal to its odd order derivatives. To find the efficiency of the proposed exponential pulse shaping function we analyze its essential characteristics and compare them with those of the conventional Gaussian pulses. We can choose the most suitable exponential pulse waveform according to the design criteria of communication systems.

  • PDF