• Title/Summary/Keyword: PTV coverage

Search Result 52, Processing Time 0.025 seconds

Study of overlapping setting up of Planning Target Volume for Improving Target Coverage adjacent Organ At Risk (손상위험장기에 인접한 표적 Coverage 개선을 위한 Planning Target Volume 중복 설정에 관한 연구)

  • Lee, Jung Woong;Kim, Bo Kyum;Mun, Jun Ki;Woo, Hun;Lee, Yang Hoon;Jeon, Chang Woo;Lee, Jea Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.33-41
    • /
    • 2019
  • Purpose: The purpose of this study is to improve the reduction of coverage of PTVs adjacent to organ at risk (OAR) by setting up overlapping Planning Target Volume (PTV) during Volumetric Modulated Arc Therapy(VMAT). Materials and Methods: In patients who received Whole Brain, Gall Bladder and Rectum radiation therapy, We compared the cover change, maximum dose, Homogenicity Index and Conformity Index of PTV and also compared the maximum dose and average dose change of Organ At Risk by organizing treatment plans that are not applied overlaped PTV and treatment plans that are applied overlaped PTV in areas where coverage is insufficient. Results: overage of treatment plans with overlapping PTVs was increased in all patients, and overall coverage was also increased in each of the four patients. The maximum dose for PTV was increased in five patients, and the Homogenicity Index and Conformity Index for all patients did not differ much. The maximum dose of the lens was increased by 1.12 times, and the maximum dose was decreased in two patients for brain stem. The mean dose of the eyeball was increased by a maximum of 1.15 times, and there was no significant difference between both parotid gland. In case of gallbladder cancer patients, the mean dose in the liver and colon was decreased, and the mean dose in the duodenum was increased. In the case of rectal cancer patients, the mean dose was reduced for both femur and bladder set as OARs. The overall MU was shown to be similar in four patients, excluding one. Conclusion: If the critical dose of OAR is considered and used properly, I think it is a useful way to improve coverage of PTV.

The Dosimetric Effect on Real PTV and OARs at Various Image Fusion Protocol for Pituitary Adenomas (뇌하수체 종양의 방사선 수술 시 영상 융합 프로토콜이 실제 PTV와 OAR 선량에 미치는 영향)

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.354-359
    • /
    • 2010
  • The purpose of this study is to verify the dosimetric effect on real PTV (planning target volume) coverage and safety of OARs (organs at risk) at various image fusion protocol-based radiosurgery plan for pituitary adenomas. Real PTV coverage and its variation was acquired and maximum dose and the volume absorbing above threshold dose were also measured for verifying the safety of optic pathway and brainstem. The protocol that can reduce superior-inferior uncertainty by using both axial and coronal MR (magnetic resonance) image sets shows relatively lower values than that of case using only axial image sets. As a result, the image fusion protocol with both axial and coronal image sets can be beneficial to generate OAR-weighted radiosurgery plan.

Plan Dose Evaluation of Three Dimensional Conformal Radiotherapy Planning (3D-CRT) of Nasopharyngeal Carcinoma (NPC): Experience of a Tertiary Care University Hospital in Pakistan

  • Abbasi, Ahmed Nadeem;Hafiz, Asim;Ali, Nasir;Khan, Khurshid Ahmed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5989-5993
    • /
    • 2013
  • Background: Radiation therapy is the mainstay of treatment for nasopharyngeal carcinoma. Importance of tumor coverage and challenges posed by its unique and critical location are well evident. Therefore we aimed to evaluate our radiation treatment plan through dose volume histograms (DVHs) to find planning target volume (PTV) dose coverage and factors affecting it. Materials and Methods: This retrospective study covered 45 histologically proven nasopharyngeal cancer patients who were treated with definitive 3D-CRT and chemotherapy between Feb 2006 to March 2013 at the Department of Oncology, Section Radiation Oncology, Aga Khan University Hospital, Karachi, Pakistan. DVH was evaluated to find numbers of shrinking field (phases), PTV volume in different phases and its coverage by the 95% isodose lines, along with influencing factors. Results: There were 36 males (80%) and 9 females (20%) in the age range of 12-84 years. Stage IVA (46.7%) was the most common stage followed by stage III (31.1). Eighty six point six-percent received induction, 95.5% received concurrent and 22.2% received adjuvant chemotherapy. The prescribed median radiation dose was 70Gy to primary, 60Gy to clinically positive neck nodes and 50Gy to clinically negative neck regions. Mean dose to spinal cord was 44.2Gy and to optic chiasma was 52Gy. Thirty seven point eight-percent patients completed their treatment in three phases while 62.2% required four to five phases. Mean volume for PTV3 was $247.8cm^3$ (50-644.3), PTV4 $173.8cm^3$ (26.5-345.1) and PTV5 $119.6cm^3$ (18.9-246.1) and PTV volume coverage by 95% isodose lines were 74.4%, 85.7% and 100% respectively. Advanced T stage, intracranial extension and tumor volume > $200cm^3$ were found to be important factors associated with decreased PTV coverage by 95% isodose line. Conclusions: 3D CRT results in adequate PTV dose coverage by 95% isodose line. However advanced T stage, intracranial extension and large target volume require more advanced techniques like IMRT for appropriate PTV coverage.

Convolution-Superposition Based IMRT Plan Study for the PTV Containing the Air Region: A Prostate Cancer Case (Convolution-Superposition 알고리즘을 이용한 치료계획시스템에서 공기가 포함된 표적체적에 대한 IMRT 플랜: 전립선 케이스)

  • Kang, Sei-Kwon;Yoon, Jai-Woong;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.271-277
    • /
    • 2013
  • In prostate IMRT planning, the planning target volume (PTV), extended from a clinical target volume (CTV), often contains an overlap air volume from the rectum, which poses a problem inoptimization and prescription. This study was aimed to establish a planning method for such a case. There can be three options in which volume should be considered the target during optimization process; PTV including the air volume of air density ('airOpt'), PTV including the air volume of density value one, mimicking the tissue material ('density1Opt'), and PTV excluding the air volume ('noAirOpt'). Using 10 MV photon beams, seven field IMRT plans for each target were created with the same parameter condition. For these three cases, DVHs for the PTV, bladder and the rectum were compared. Also, the dose coverage for the CTV and the shifted CTV were evaluated in which the shifted CTV was a copied and translated virtual CTV toward the rectum inside the PTV, thus occupying the initial position of the overlap air volume, simulating the worst condition for the dose coverage in the target. Among the three options, only density1Opt plan gave clinically acceptable result in terms of target coverage and maximum dose. The airOpt plan gave exceedingly higher dose and excessive dose coverage for the target volume whereas noAirOpt plan gave underdose for the shifted CTV. Therefore, for prostate IMRT plan, having an air region in the PTV, density modification of the included air to the value of one, is suggested, prior to optimization and prescription for the PTV. This idea can be equally applied to any cases including the head and neck cancer with the PTV having the overlapped air region. Further study is being under process.

Dosimetric Comparison between Intensity Modulated Radiotherapy and 3 Dimensional Conformal Radiotherapy in the Treatment of Rectal Cancer

  • Simson, David K;Mitra, Swarupa;Ahlawat, Parveen;Sharma, Manoj Kumar;Yadav, Girigesh;Mishra, Manindra Bhushan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.11
    • /
    • pp.4935-4937
    • /
    • 2016
  • Objective: To compare dosimetric parameters of 3 dimensional conformal radiotherapy (3 DCRT) and intensity modulated radiotherapy (IMRT) in terms of target coverage and doses to organs at risk (OAR) in the management of rectal carcinoma. Methods: In this prospective study, conducted between August 2014 and March 2016, all patients underwent CT simulation along with a bladder protocol and target contouring according to the Radiation Therapy Oncology Group (RTOG) guidelines. Two plans were made for each patient (3 DCRT and IMRT) for comparison of target coverage and OAR. Result: A total of 43 patients were recruited into this study. While there were no significant differences in mean Planning Target Volume (PTV) D95% and mean PTV D98% between 3 DCRT and IMRT, mean PTV D2% and mean PTV D50% were significantly higher in 3 DCRT plans. Compared to IMRT, 3 DCRT resulted in significantly higher volumes of hot spots, lower volumes of cold spots, and higher doses to the entire OAR. Conclusion: This study demonstrated that IMRT achieves superior normal tissue avoidance (bladder and bowel) compared to 3 DCRT, with comparable target dose coverage.

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

A study on the effect of collimator angle on PAN-Pelvis volumetric modulated arc therapy (VMAT) including junction (접합부를 포함한 PAN-전골반암 VMAT 치료 계획 시 콜리메이터 각도의 영향에 관한 고찰)

  • Kim, Hyeon Yeong;Chang, Nam Jun;Jung, Hae Youn;Jeong, Yun Ju;Won, Hui Su;Seok, Jin Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.61-71
    • /
    • 2020
  • Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.

Dose Planning Study of Target Volume Coverage with Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma: Penang General Hospital Experience

  • Vincent Phua, Chee Ee;Tan, Boon Seang;Tan, Ai Lian;Eng, Kae Yann;Ng, Bong Seng;Ung, Ngie Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2243-2248
    • /
    • 2013
  • Background: To compare the dosimetric coverage of target volumes and organs at risk in the radical treatment of nasopharyngeal carcinoma (NPC) between intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3DCRT). Materials and Methods: Data from 10 consecutive patients treated with IMRT from June-October 2011 in Penang General Hospital were collected retrospectively for analysis. For each patient, dose volume histograms were generated for both the IMRT and 3DCRT plans using a total dose of 70Gy. Comparison of the plans was accomplished by comparing the target volume coverage (5 measures) and sparing of organs at risk (17 organs) for each patient using both IMRT and 3DCRT. The means of each comparison target volume coverage measures and organs at risk measures were obtained and tested for statistical significance using the paired Student t-test. Results: All 5 measures for target volume coverage showed marked dosimetric superiority of IMRT over 3DCRT. V70 and V66.5 for PTV70 showed an absolute improvement of 39.3% and 24.1% respectively. V59.4 and V56.4 for PTV59.4 showed advantages of 18.4% and 16.4%. Moreover, the mean PTV70 dose revealed a 5.1 Gy higher dose with IMRT. Only 4 out of 17 organs at risk showed statistically significant difference in their means which were clinically meaningful between the IMRT and 3DCRT techniques. IMRT was superior in sparing the spinal cord (less 5.8Gy), V30 of right parotid (less 14.3%) and V30 of the left parotid (less 13.1%). The V55 of the left cochlea was lower with 3DCRT (less 44.3%). Conclusions: IMRT is superior to 3DCRT due to its dosimetric advantage in target volume coverage while delivering acceptable doses to organs at risk. A total dose of 70Gy with IMRT should be considered as a standard of care for radical treatment of NPC.

Volumetric-Modulated Arc Radiotherapy Using Knowledge-Based Planning: Application to Spine Stereotactic Body Radiotherapy

  • Jeong, Chiyoung;Park, Jae Won;Kwak, Jungwon;Song, Si Yeol;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.94-103
    • /
    • 2019
  • Purpose: To evaluate the clinical feasibility of knowledge-based planning (KBP) for volumetric-modulated arc radiotherapy (VMAT) in spine stereotactic body radiotherapy (SBRT). Methods: Forty-eight VMAT plans for spine SBRT was studied. Two planning target volumes (PTVs) were defined for simultaneous integrated boost: PTV for boost (PTV-B: 27 Gy/3fractions) and PTV elective (PTV-E: 24 Gy/3fractions). The expert VMAT plans were manually generated by experienced planners. Twenty-six plans were used to train the KBP model using Varian RapidPlan. With the trained KBP model each KBP plan was automatically generated by an individual with little experience and compared with the expert plan (closed-loop validation). Twenty-two plans that had not been used for KBP model training were also compared with the KBP results (open-loop validation). Results: Although the minimal dose of PTV-B and PTV-E was lower and the maximal dose was higher than those of the expert plan, the difference was no larger than 0.7 Gy. In the closed-loop validation, D1.2cc, D0.35cc, and Dmean of the spinal cord was decreased by 0.9 Gy, 0.6 Gy, and 0.9 Gy, respectively, in the KBP plans (P<0.05). In the open-loop validation, only Dmean of the spinal cord was significantly decreased, by 0.5 Gy (P<0.05). Conclusions: The dose coverage and uniformity for PTV was slightly worse in the KBP for spine SBRT while the dose to the spinal cord was reduced, but the differences were small. Thus, inexperienced planners could easily generate a clinically feasible plan for spine SBRT by using KBP.

Neck Node Bolus Technique in the Treatment of Nasopharyngeal Carcinoma with Intensity-modulated Radiotherapy

  • Phua, Chee Ee;Ung, Ngie Min;Tan, Boon Seang;Tan, Ai Lian;Eng, Kae Yann;Ng, Bong Seng
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.12
    • /
    • pp.6133-6137
    • /
    • 2012
  • Purpose: To study the effect of bolus versus no bolus in the coverage of the nodal tumour volume with intensity-modulated radiotherapy (IMRT) for the treatment of nasopharyngeal carcinoma (NPC). Methods and Materials: This retrospective study used data from 5 consecutive patients with NPC who were treated with bolus for large neck nodes using IMRT from November 2011-January 2012 in our institute. All these patients were treated radically with IMRT according to our institution's protocol. Re-planning with IMRT without bolus for these patients with exactly the same target volumes were done for comparison. Comparison of the plans was done by comparing the V70 of PTV70-N, V66.5 of PTV70-N, V65.1 of PTV70-N and the surface dose of the PTV70-N. Results: The mean size of the largest diameter of the enlarged lymph nodes for the 5 patients was 3.9 cm. The mean distance of the GTV-N to the skin surface was 0.6 cm. The mean V70 of PTV70-N for the 5 patients showed an absolute advantage of 10.8% (92.4% vs. 81.6%) for the plan with bolus while the V66.5 of PTV70-N had an advantage of 8.1% (97.0% vs. 88.9%). The mean V65.1 also had an advantage of 7.1% (97.6% vs. 90.5%). The mean surface dose for the PTV70-N was also much higher at 61.1 Gy for the plans with bolus compared to only 23.5 Gy for the plans without bolus. Conclusion: Neck node bolus technique should be strongly considered in the treatment of NPC with enlarged lymph nodes treated with IMRT. It yields a superior dosimetry compared t o non-bolus plans with acceptable skin toxicity.