• Title/Summary/Keyword: PT-Ir

Search Result 182, Processing Time 0.031 seconds

Simultaneous Determination of Traces of Platinum and Rhodium by Differential Pulse Polarograpy (펄스 차이 폴라로그래피법에 의한 미량 백금과 로듐의 동시 정량)

  • Czae, Myoung-Zoon;Lee, Chul;Hong, Tae-Kee;Kwon, Young-Soon;Hong, Mi-Jeong
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.1
    • /
    • pp.35-39
    • /
    • 1995
  • Simultaneous measurements of trace platinum and rhodium, based on catalytic reduction of protons by the adsorbed Pt-formazone and Rh-formaldehyde complexes formed in formaldehyde-hydrazine-sulfuric acid medium, were demonstrated. The conditions for the measurements of Pt and Rh both present at trace levels (>10-10 M) were 0.004% (w/v) formaldehyde-0.0012% (w/v) hydrazine-0.75 M sulfuric acid. In this medium method detection limits are 7.3${\times}$10-11 M Pt and 3.2${\times}$10-11 M Rh. And dynamic ranges are 5${\times}$10-10~6${\times}$10-8 M and 1${\times}$10-10∼2${\times}$10-8 M for platinum and rhodium respectively. In the linear dynamic ranges, Rh and Ir interfere platinum in the presence of only 10 and 100 times that of Pt respectively. There are no interferences from other platinum group metal ions for rhodium even in the presence of a 500-fold excess of Ir(IV), a hundredfold excess of platinum.

  • PDF

Decolorization of a Rhodamine B Using Ru-graphite Electrode (Ru-흑연 전극을 이용한 Rhodamine B의 색 제거)

  • Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.17 no.5
    • /
    • pp.547-553
    • /
    • 2008
  • For the RhB removal from the wastewater, electrochemical method was adapted to this study. Three dimensionally stable anode (Pt, Ir and Ru) and graphite and Ru cathode were used. In order to identify decolorization, the effects of electrode, current density, electrolyte and air flow rate were investigated. The effects of electrode material, current, electrolyte concentration and air flow rate were investigated on the decolorization of RhB. Electro-Fenton's reaction was evaluated by added $Fe^{2+}$ and $H_2O_2$ generated by the graphite cathode. Performance for RhB decolorization of the four electrode systems lay in: Ru-graphite > Ru-Ru > Ir-graphite > Pt-graphite. A complete color removal was obtained for RhB (30 mg/L) at the end of 30 min of electrolysis under optimum operations of 2 g/L NaCl concentration and 2 A current. $Fe^{2+}$ addition increased initial reaction and decreased final RhB concentration. However the effect was not high.

Comparative studies of ohmic metallization on p-GaAsSb (금속에 따른 p-GaAsSb 오믹접촉의 전기적 특성에 관한 비교 연구)

  • Cho, Seung-Woo;Jang, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.33-36
    • /
    • 2004
  • 탄소 도핑$(5{\times}10^{19}\;cm^{-3})$된 p-type GaAsSb 에피층 위에, Ti/Pt/Au, Pd/Au, Pd/Ir/Au를 이용한 다층 오믹 접촉을 제작하였다. MOCVD(metal-organic chemical vapor deposition)를 이용하여 성장시킨 이 p-GaAsSb의 정공 이동도는 탄소의 도핑 농도가 매우 높음에도 불구하고, $50\;cm^2/Vs$로 측정되었다. 오믹 접촉의 전기적 특성을 측정하기 위하여 TLM(Transfer length method)를 이용하였다. Pd/Ir/Au을 이용한 오믹접촉의 specific contact resistivity는 $10^{-8}\;ohm-cm^2$ 보다 작은 수치를, transfer length는 100 nm보다 작은 수치를 보였으며, Ti/Pt/Au을 이용한 ohmic contact의 specific contact resistivity는 $10^{-7|\;ohm-cm^2$ 보다 작은 수치를, transfer length는 400 nm보다 작은 수치를 나타내었다.

  • PDF

Charge Transfer between STM Tip and Au(100) in Dry, H2O, and D2O Atmospheres

  • Utami, Anggi;Chung, Yonghwa;Lee, Chi-Woo
    • Journal of Electrochemical Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.153-156
    • /
    • 2013
  • Charge transfer between STM tip and Au(100) has been investigated by using a Scanning Tunneling Microscopy (STM) technique in dry, $H_2O$, and $D_2O$ atmospheres. Dry atmosphere was indicated by humidity as low as 5 % and high humidity as high as 98% was managed by injecting $H_2O$ and $D_2O$ to the chamber. The current decayed more slowly in high humidity than in dry atmosphere. The plateau currents were found to appear at separations larger than ca. $5{\AA}$ where the current decay stopped depending on applied bias voltages. The polarity dependence was observed at the STM junction between Pt-Ir tip and the gold. On the contrary, little dependence was seen at the one between Au tip and the substrate electrode.

Effects of Pt and Ir Electrodes on $Pb(Zr_xTi_{1-x})O_3$ Thin Films Deposited at Low Temperature(400$^{\circ}C$-500$^{\circ}C$) by Metal-Organic Chemical Vapor Deposition with Liquid Delievery System (액체수송 유기금속 화학증착법(LDS-MOCVD)에 의해 Pt전극과 Ir전극 위에 저온(400$^{\circ}C$-500$^{\circ}C$)증착된 $Pb(Zr_xTi_{1-x})O_3$ 박막의 특성분석)

  • Kim, Hye-Ryeong;Jeong, Si-Hwa;Jeon, Chung-Bae;Gwon, O-Seong;Hwang, Cheol-Seong;Han, Yeong-Gi;Yang, Du-Yeong;O, Gi-Yeong;Hwang, Cheol-Ju
    • Proceedings of the Korean Ceranic Society Conference
    • /
    • 2000.10a
    • /
    • pp.161.1-161
    • /
    • 2000
  • PDF

Electrochemical Properties of Novel Metal Powder Electrodes for Polymer Electrolyte Membrane Electrolysis

  • Kim, Chang-Hee;Kang, Kyung-Soo;Park, Chu-Sik;Hwang, Gab-Jin;Bae, Ki-Kwang
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1227-1228
    • /
    • 2006
  • The electrochemical properties of novel metal powders were investigated for the electrode materias of polymer electrolyte memebrane electrolysis. Two types of Pt black and $IrO_2$ powder electrodes were hot-pressed on the polymer electrolyte membrane to form membrane electrode assembly. The galvanodynamic polarization methode was used to characterize the electrochemical properties of both electrodes. From the experimental results, we concluded that the $IrO_2$ powder electrode exhibits better electrochemical performance than Pt black as cathode material for the electrolysis.

  • PDF

Inactivation of Legionella pneumophila by Electrochemical Disinfection (전기화학적 소독에 의한 Legionella pneumophila 불활성화)

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.613-619
    • /
    • 2007
  • This study has carried out a performance of dimensionally stable anode for the purpose of disinfection of Legionella pneumophila in water. Three kinds of electrode were prepared by plating and thermal deposition, which were coated by the oxides of Pt, Ru and Ir on Ti metal surface, respectively. The order of disinfection performance for Legionella pneumophila was Ru/Ti > Ir/Ti > Pt/Ti. Free Cl and $ClO_2$ generation of Ir/Ti electrode was higher than that of two electrodes. However, the concentrations of generated $H_2O_2$ and $O_3$ of the Ru/Ti electrode were highest among the three electrodes. The higher NaCl concentration was, the more oxidants was generated and disinfection effect was increased. However, optimum NaCl dosage was 0.0125% due to the regulation on the conductivity and $Cl^-$ concentration for the cooling water quality of air conditioning and refrigeration equipment. With the increase of current, oxidants was more generated and following disinfection effect was increased. The increase of electrode distance reduced oxidants generation due to the low electric power, and their disinfection effect was decreased accordingly.

A Spatial-domain Fourier Transform Infrared Spectrometer: Application for Analyte Measurement in Cell Culture Media

  • Jung, Byung-Jo
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.4
    • /
    • pp.151-156
    • /
    • 2005
  • A spatial-domain Fourier Transform (FT) infrared (IR) spectrometer coupled with a PtSi Schottky­barrier IR detector plane was developed in the spectral range of $2.0-2.5{\mu}m$ for noninvasive measurement of analyte concentrations in cell culture media during cell culture processing. A key optical component of the spectrometer is a Savart plate which is a birefringent polarizer generating coherent two rays for interfering. The spectral resolution of the spectrometer was determined as $71cm^{-1}$ (${\~}0.05{\mu}m$ at $2.5{\mu}m$). Clear IR fringe patterns were imaged on the IR detector plane. The feasibility of the spectrometer for our application was investigated by measuring absorbance spectra of glucose and fetal bovine serum (FBS) which are important compounds in cell culture media. Experiment results show that the spectral quality of glucose and FBS was comparable with the standard spectra acquired with a commercial FT-IR spectrometer, presenting the feasibility of the spectrometer to perform analyte measurement in cell culture media.

Thermal Behavior of Langmuir-Blodgett Film of Poly(tert-butyl methacrylate) by Principal Component Analysis Based Two-Dimensional Correlation Spectroscopy

  • Jung, Young-Mee;Kim, Seung-Bin
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.12
    • /
    • pp.2027-2032
    • /
    • 2005
  • This paper demonstrates details of thermal behavior of Langmuir-Blodgett (LB) film of poly(tert-butyl methacrylate) (PtBMA) by using the principal component analysis based two-dimensional correlation spectroscopy (PCA2D) through eigenvalue manipulating transformation (EMT). By uniformly lowering the power of a set of eigenvalues associated with the original data, the smaller eigenvalues becomes more prominent and the subtle contribution from minor components is now highlighted much more strongly than the original data. Thus, the subtle difference of thermal behavior of LB film of PtBMA from minor components, which is not readily detectable in the conventional 2D correlation analysis, is much more noticeable than the original data. PCA2D correlation spectra with EMT operation for the temperature-dependent IR spectra of LB film of PtBMA reveal the hidden property of phase transition processes during heating.