• Title/Summary/Keyword: PSG

Search Result 219, Processing Time 0.025 seconds

Polysomnographic Assessment of Nocturnal Enuresis in Adults: A Case Study of Parasomnia Overlap Syndrome With Obstructive Sleep Apnea

  • Jiyeon Moon;Wooyoung Im;Hyeyun Kim
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.31 no.2
    • /
    • pp.173-175
    • /
    • 2023
  • Enuresis nocturia is more prevalent in children than in adults. Using polysomnography (PSG), we investigated the causes of adult enuresis nocturia in a 20-year-old female patient with nighttime bedwetting. In spite of normal urological examinations, her detailed medical history disclosed frequent sleep paralysis and urination during dreams. During PSG, two electromyograms were attached to her anus to assess the tone of her bladder's sphincter while she slept. During REM sleep, the EMG tone of the mandible decreased, but the anal and bladder sphincter tones did not. The polysomnogram revealed moderate obstructive sleep apnea. Consequently, she was diagnosed with adult parasomnia (nocturnal enuresis) overlap syndrome with OSA. This study demonstrates the value of PSG with simultaneous anal tone EMG for diagnosing NREM parasomnia and nocturnal enuresis.

The Study on the Characteristic of Mono Crystalline Silicon Solar Cell with Change of $O_2$ Injection during Drive-in Process and PSG Removal (단결정 실리콘 태양전지 도핑 확산 공정에서 주입되는 $O_2$ 가스와 PSG 유무에 따른 특성 변화)

  • Choi, Sung-Jin;Song, Hee-Eun;Yu, Gwon-Jong;Lee, Hi-Deok
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.105-110
    • /
    • 2011
  • The doping procedure in crystalline silicon solar cell fabrication usually contains oxygen injection during drive-in process and removal of phosphorous silicate glass(PSG). In this paper, we studied the effect of oxygen injection and PSG on conversion efficiency of solar cell. The mono crystalline silicon wafers with $156{\times}156mm^2$, $200{\mu}m$, $0.5-3.0{\Omega}{\cdot}cm$ and p-type were used. After etching $7{\mu}m$ of the surface to form the pyramidal structure, the P(phosphorous) was injected into silicon wafer using diffusion furnace to make the emitter layer. After then, the silicon nitride was deposited by the PECVD with 80 nm thickness and 2.1 refractive index. The silver and aluminium electrodes for front and back sheet, respectively, were formed by screen-printing method, followed by firing in 400-425-450-550-$880^{\circ}C$ five-zone temperature conditions to make the ohmic contact. Solar cells with four different types were fabricated with/without oxygen injection and PSG removal. Solar cell that injected oxygen during the drive-in process and removed PSG after doping process showed the 17.9 % conversion efficiency which is best in this study. This solar cells showed $35.5mA/cm^2$ of the current density, 632 mV of the open circuit voltage and 79.5 % of the fill factor.

  • PDF

Measurement of residual stress of TEOS and PSG for MEMS (MEMS용 PSG와 TEOS의 열처리에 따른 잔류응력의 측정)

  • Yi, Sang-Woo;Lee, Sang-Woo;Kim, Jong-Pal;Park, Sang-Jun;Lee, Sang-Chul;Kim, Sung-Un;Cho, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2536-2538
    • /
    • 1998
  • This paper investigates the residual stress of tetraethoxysilane (TEOS) and 7wt% phosphosilicate glass (PSG), which are commonly used as a sacrificial layer or etch mask in the fabrication of microelectromechanical systems (MEMS). In order to measure residual stress, $2{\mu}m$ thick TEOS and PSG stress measurement structures are fabricated. Polysilicon is used as the sacrificial layer. First the residual stress of an as-deposited 7wt% PSG flim and TEOS film are measured to be-0.3115% and -0.435%, respectively, which are quite large. These films are annealed from $500^{\circ}C$ to $800^{\circ}C$. Annealing has the effects of reducing residual stress. In the case of the 7wt% PSG film, the residual stress becomes +0.00715% after annealing at $625^{\circ}C$ for 150 minutes. In the case of TEOS film, the residual stress reduces to -0.2134% after same condition. Incidentally, this condition is the same condition for depositing a $2{\mu}m$ thick polysilicon at $625^{\circ}C$ at our low pressure chemical vapor deposition (LPCVD) furnace.

  • PDF

Patient-specific Guides Using 3-dimensional Reconstruction Provide Accuracy and Reproducibility in Reverse Total Shoulder Arthroplasty

  • Yoon, Jong Pil;Kim, Dong Hyun;Jung, Jae Wook;Lee, Chang-Hwa;Min, Seunggi;Lee, Hyun Joo;Kim, Hee-June
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.16-23
    • /
    • 2019
  • Background: We aimed to evaluate whether the use of our novel patient-specific guide (PSG) with 3-dimensional reconstruction in reverse total shoulder arthroplasty (RTSA) would allow accurate and reliable implantation of the glenoid and humeral components. Methods: 20 fresh-frozen cadaveric shoulders were used. The PSG group (n=10) and conventional group (n=10) was evaluated the accuracy and reproducibility of implant positioning between before and after surgery on the computed tomography image. Results: The superoinferior and anteroposterior offset in the glenoid component were $0.42{\pm}0.07$, $0.50{\pm}0.08$ in the conventional group and $0.45{\pm}0.03$, $0.46{\pm}0.02$ in the PSG group. The inclination and version angles were $-1.93^{\circ}{\pm}4.31^{\circ}$, $2.27^{\circ}{\pm}5.91^{\circ}$ and $0.46^{\circ}{\pm}0.02^{\circ}$, $3.38^{\circ}{\pm}2.79^{\circ}$. The standard deviation showed a smaller difference in the PSG group. The anteroposterior and lateromedial humeral canal center offset in the humeral component were $0.45{\pm}0.12$, $0.48{\pm}0.15$ in the conventional group and $0.46{\pm}0.59$ (p=0.794), $0.46{\pm}0.06$ (p=0.702) in the PSG group. The PSG showed significantly better humeral stem alignment. Conclusions: The use of PSGs with 3-dimensional reconstruction reduces variabilities in glenoid and humerus component positions and prevents extreme positioning errors in RTSA.

Studies on the Immunomodulating Effects of Polysaccharide Extracted from Ganoderma lucidum on Macrophage (영지버섯 다당체의 마우스 대식세포 면역증강 효과)

  • 김성환;김을상
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.1
    • /
    • pp.148-153
    • /
    • 1997
  • The immunomodulating effects of polysaccharide extracted from Ganoderma lucidum(PSG) on macrophage were evaluated using murine macrophage cell line ATCC TIB 71 cells or peritoneal exudate cells of BALB/c mice. The cell were incubated with various content of PSG for 24 hours at 0.5% $CO_2$ incubator under varying experimental conditions. PSG stimulated the non-specific activites of macrophage such as mitotic activity and expression of surface interleukin-2 receptors by dose-dependent pattern with statistic significance(p<0.001): however, PSG had little immunoregulatory effects on cytokines derived from peritoneal macrophages of BALB/c mice. There were no significant changes in the se-cretion of interleukin-6, interleukin-6, or tumor necrosis factors(Tn) of PSG treated cells compared to the control group. But PSG increased secretion of cytokines(IL-1 and TNF) when the cells were primed and trigged with BCG and IFN-${\gamma}$.

  • PDF

EXISTENCE, UNIQUENESS AND STABILITY OF IMPULSIVE STOCHASTIC PARTIAL NEUTRAL FUNCTIONAL DIFFERENTIAL EQUATIONS WITH INFINITE DELAYS

  • Anguraj, A.;Vinodkumar, A.
    • Journal of applied mathematics & informatics
    • /
    • v.28 no.3_4
    • /
    • pp.739-751
    • /
    • 2010
  • This article presents the result on existence, uniqueness and stability of mild solution of impulsive stochastic partial neutral functional differential equations under sufficient condition. The results are obtained by using the method of successive approximation.

A New HF/$NH_4F$/Glycerine Aqueous Solution for Protection of Al Layers During Sacrificial Etching of PSG Films (PSG 희생층 식각시 Al층을 보호하기 위한 새로운 HF/$NH_4F$/Glycerine 혼합 식각액)

  • Kim, Sung-Un;Paik, Seung-Joon;Kim, Im-Jung;Lee, Seung-Ki;Cho, Dong-Il
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.414-420
    • /
    • 1999
  • The oxide sacrificial layer technology is one of the key technologies in surface micromachining. However, the commonly used aqueous HF solutions, including the $NH_4F$ buffered HF solutions (BHF), are known to attack the Al metal layers during the oxide sacrificial etch. A mixed $NH_4F$/HF/glycerine aqueous solution of 4:1:2 ratio is known to have the best etch selectivity between oxide and AI, but even this sacrificial etchant has a significant etch rate for AI. This paper reports an extensive experimental study on various concentration ratios for HF, $NH_4F$ and glycerine, and develops the optimal mixture ratio for sacrificial etching. At the $NH_4F$/HF/glycerine ratio of 2:1:4, the etch selectivity between PSG and Al improves by approximately 6 times over the previously known best selectivity, to a value of 7,700. At this condition, the measured etch rate of PSG film is approximately $2.1\;{\mu}m/min$, which is sufficiently fast. The developed sacrificial etchant allows the addition of a Al metal layer in surface micromachining, without the worry of Al layer erosion during sacrificial etch.

  • PDF

A Fabrication and Characteristic Estimation of Polycrystalline Silicon Structural Layer for Micromachining (미세가공용 다결정 실리콘 구조체의 제작 및 특성 평가)

  • Kim, Hyoung-Dong;Pack, Seung-Ho;Lee, Seong-Jun;Kim, Chul-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1442-1444
    • /
    • 1995
  • In this study, we confirmed that the crystallinity and the mechanical properties of polycrystalline Silicon(poly-Si) deposited on the poly-oxide are better than those of poly-Si on the conventional sacrificial layers that is CVD oxide layer or PSG. But the etch rate of poly-oxide is poor than that of the CVD oxide layer or PSG. Therefore, to make the best use of small stress and fast etch rate, we fabricated the double oxide layer; 10%-thick poly-oxide on 90%-thick CVD oxide or PSG. To estimate structure deformation by stress, we fabricated the test structures; cantilever. bridge and ring/beam structure and estimated by SEM. As the results, all structure is expressed the deformed structure by residual stress(tensile stress) and the deformation of the structure layer on the double oxide layer is small compared with that of the structure layer on the CVD oxide layer or PSG. And, the etch rate of the double oxide layer is enhanced compared with that of the poly-oxide.

  • PDF

Diffusion characterization of Doped Oxide and Nitride Film (도핑한 산화막 및 질화막의 확산특성)

  • 이종덕;김원찬
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.2
    • /
    • pp.97-105
    • /
    • 1985
  • Phosphorus and boron diffusion from doped PECVD oxide films into silicon have been studied. CVD PSG was also prepared to parallelly compare the diffusion characteristics of CVD PSG with that in PECVD PSG, The phosphorus diffusion experiments were performed in N2 and O2 ambient at the temperatures of 100$0^{\circ}C$, 105$0^{\circ}C$ and 110$0^{\circ}C$ The parameters of boron diffusion have been investigated from the doped film prepared by changing B2 H6 flow rate and deposition temperature. The diffusivities and diffusion profiles of the dopant into silicon were calculated by applying Barry's model using the measured parameters such as diffusion depth and surface concentration.

  • PDF

Dynamic behavior of smart material embedded wind turbine blade under actuated condition

  • Mani, Yuvaraja;Veeraragu, Jagadeesh;Sangameshwar, S.;Rangaswamy, Rudramoorthy
    • Wind and Structures
    • /
    • v.30 no.2
    • /
    • pp.211-217
    • /
    • 2020
  • Vibrations of a wind turbine blade have a negative impact on its performance and result in failure of the blade, therefore an approach to effectively control vibration in turbine blades are sought by wind industry. The small domestic horizontal axis wind turbine blades induce flap wise (out-of-plane) vibration, due to varying wind speeds. These flap wise vibrations are transferred to the structure, which even causes catastrophic failure of the system. Shape memory alloys which possess physical property of variable stiffness across different phases are embedded into the composite blades for active vibration control. Previously Shape memory alloys have been used as actuators to change their angles and orientations in fighter jet blades but not used for active vibration control for wind turbine blades. In this work a GFRP blade embedded with Shape Memory Alloy (SMA) and tested for its vibrational and material damping characteristics, under martensitic and austenite conditions. The embedment portrays 47% reduction in displacement of blade, with respect to the conventional blade. An analytical model for the actuated smart blade is also proposed, which validates the harmonic response of the smart blade.