• Title/Summary/Keyword: PSG

Search Result 219, Processing Time 0.022 seconds

Fabrication and Characterization of LPCVD LPCVD $P_2O_5-SiO_2$ Filmsfor Integrated Optics (2):-Comparison Between TMPate and $PH_3$ as a Dopant of P in PSG Films- (LPCVD $P_2O_5-SiO_2$ 집적광학박막의 제작 및 특성연구(2): TMPate와 $PH_3$의 비교)

  • 정환재;이형종;이용태;전은숙;김순창;양순철
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.233-238
    • /
    • 1995
  • '#65279;We made $P_2O_5-SiO_2$ films on silicon for integrated optics application by low pressure chemical vapor deposition using TEOS(tetraethylorthosilicate), TMPite(trimethylphosphite) and phosphine($PH_3$). And We studied and compared between TMPite and PH, as a dopant of P in PSG films in the aspect of the de,position characteristics. Deposition rate of TMPate-PSG films was $55 \AA/min$ which was smaller than 90 A/min , that of $PH_3-PSG$ films. Thickness deviation of TMPate-PSG films was 2% and that of PH3-PSG was 4.5%. So TMPate-PSG films had a good quality in thickness uniformity. The range of refractive index was controlled from 1.445 to 1.468 at 633 nm in TMPate-PSG films and it was controlled from 1.456 to 1.476 in $PH_3-PSG$ films.

  • PDF

Preliminary Study of The Periodic Limb Movement Disorder Following Nasal CPAP : Is It Associated With Supine-Sleeping Position? (지속적 양압술과 수면중 주기적 사지운동 장애의 관계에 대한 예비적 연구 : 앙와위가 주기적 사지운동 장애와 관련되는가?)

  • Yang, Chang-Kook;Clerk, Alex A
    • Sleep Medicine and Psychophysiology
    • /
    • v.4 no.2
    • /
    • pp.164-171
    • /
    • 1997
  • Introduction : Periodic limb movement disorder (PLMD) is shown to common in patients with OSA and may become evident or worsened when treated with nasal continuous positive airway pressure (CPAP). Whether this is due to im proved sleep continuity. adverse nocturnal body positioning, uncovered by CPAP, or due to the CPAP stimulus is still debat-ed. We hypothesized that the increase in PLM activity following CPAP is associated with more supine-sleeping tendencies when being treated with CPAP. In the present work, we compared differences in the PLMD index (PLMI) and sleeping position of patients with sleep disordered breathing before and after CPAP treatment. Method : We studied 16 patients (mean age 46 yr, 9M, 7F) with OSA (11 patients) or UARS (5 patients) who either had PLMD on initial polysomnogram (baseline PSG) or on nasal CPAP trial (CPAP PSG). All periodic leg movements were scored on anterior tibialis EMG during sleep according to standard criteria (net duration; 0.5-5.0 seconds, intervals; 4-90 seconds. 4 consecutive movements). Paired t-tests compared PLMD index (PLMI), PLMD-related arousal index (PLMD-ArI), respiratory disturbance index (RDI), and supine sleeping position spent with baseline PSG and CPAP PSG. Results : Ten patients (63%) on baseline PSG and fifteen patients (94%) on CPAP PSG had documented PLMD ($PLMI{\ge}5$) respectively with significant increase on CPAP PSG(p<0.05). Ten patients showed the emergence (6/10 patients) or substantial worsening (4/10 patients) of PLMD during CPAP trial. Mean CPAP pressure was $7.6{\pm}1.8\;cmH_2O$. PLMI tended to increase from baseline PSG to CPAP PSG, and significantly increase when excluding 2 outlier (baseline PSG, $19.0{\pm}25.8/hr$ vs CPAP PSG, $29.9{\pm}12.5/hr$, p<0.1). PLMD-ArI showed no significant change, but a significant decrease was detected when excluding 2 outlier (p<0.1). There was no significant sleeping positional difference (supine vs non-supine) on baseline PSG, but significantly more supine position (supine vs non-supine, p<0.05) on CPAP PSG. There was no significant difference in PLMI during supine-sleeping and nonsupine-sleeping position on both of baseline PSG and CPAP PSG. There was also no significant difference in PLMI during supine-sleeping position between baseline PSG and CPAP PSG. With nasal CPAP, there was a highly significant reduction in the RDI (baseline PSG, $14.1{\pm}21.3/hr$ vs CPAP PSG, $2.7{\pm}3.9/hr$, p<0.05). Conclusion : This preliminary data confirms previous findings that CPAP is a very effective treatment for OSA, and that PLMD is developed or worsened with treatment by CPAP. This data also indicates that supine-sleeping position is more common when being treated with CPAP. However, there was no clear evidence that supine position is the causal factor of increased PLMD with CPAP. It is, however, suggested that the relative movement limitation induced by CPAP treatment could be a contributory factor of PLMD.

  • PDF

Dielectric and Passivation-Related Properties of Pecvd PSG (PECVD PSG의 유전 및 보호막특성에 관한 연구)

  • 유현규;강영일
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.2
    • /
    • pp.90-96
    • /
    • 1985
  • The properties of plasma-enhanced CVD phosphorous silicate glass (PECVD PSG) for passivation layer are studied . Phosphorous contentration was analyzed with X-ray fluores-cence. As a result, PECVD PSG has a limiting phosphors concentration of about 8 mole%. Curves relating to etcll rate, infrared absorption ratio, and sheet resistivity were adapted to monitor phosphorous concentration indirectly Dielectric properties, step coverage, crack resistance, and gettering effect are discussed in both of atmospheric pressure CVD (APCVO) and PECVD oxide. PECVD SiO2 film have density of about 2.4 g/㎤ at deposition rate of 450$\AA$/min, refractive index of about 1.53, and breakdown at fields of II-13 MV/cm. Crack resistance of PECVD oxide is greater than APCVD oxide. PECVD PSG films contained with 2 mole % phosphorous show good step coverage and gettering ability. The obtained results show more advantages in PECVD PSG than in APCVD PSG for device passivation.

  • PDF

A Study on the Sodium and Moisture Gettering in PSG/SiO2 Passivated Al-1%Si Thin Film Interconnections (PSG/SiO2 보호막 처리된 Al-1%Si 박막배선에서의 Sodium과 수분 게터링에 관한 연구)

  • Kim, Jin Young
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.3
    • /
    • pp.126-130
    • /
    • 2013
  • The sodium (Na) and moisture ($H_2O$) gettering phenomena were measured and analyzed in PSG/$SiO_2$ passivated Al-1%Si thin film interconnections. PSG/$SiO_2$ passivation and Al-1%Si thin films were deposited by using APCVD (atmosphere pressure chemical vapor deposition) and DC magnetron sputter techniques, respectively. SIMS (secondary ion mass spectrometry) depth profiling analysis was used to determine the distribution of sodium and moisture throughout the PSG/$SiO_2$ passivated Al-1%Si thin film interconnections. Both sodium and moisture peaks were observed strongly at the interfaces between layers rather than within the Al-1%Si thin film interconnections. Sodium peaks were observed at the interface between PSG and $SiO_2$ passivations, while moisture peaks were not observed.

Analysis of the Na Gettering in PSG/SiO2/Al-1%Si Multilevel Thin Films using XPS and SIMS (XPS와 SIMS를 이용한 PSG/SiO2/Al-1%Si 적층 박막내의 Na 게터링 분석)

  • Kim, Jin Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.49 no.5
    • /
    • pp.467-471
    • /
    • 2016
  • In order to investigate the Na gettering, PSG/$SiO_2$/Al-1%Si multilevel thin films were fabricated. DC magnetron sputter techniques and APCVD (atmosphere pressure chemical vapor deposition) were utilized for the deposition of Al-1%Si thin films and PSG/$SiO_2$ passivations, respectively. Heat treatment was carried out at $300^{\circ}C$ for 5 h in air. SIMS (secondary ion mass spectrometry) depth profiling and XPS (X-ray Photoelectron Spectroscopy) analysis were used to determine the distribution and binding energies of Na, Al, Si, O, P and other elements throughout the PSG/$SiO_2$/Al-1%Si multilevel thin films. Na peaks were mainly observed at the the PSG/$SiO_2$ interface and at the $SiO_2$/Al-1%Si interfaces. Na impurity gettering in PSG/$SiO_2$/Al-1%Si multilevel thin films is considered to be caused by a segregation type of gettering. The chemical state of Si and O elements in PSG passivation appears to be $SiO_2$.

Stress Behavior of PSG/SiN Film for Passivation in Semiconductor Memory Device (반도체 소자의 표면보호용 PSG/SiN 절연막의 스트레스 거동)

  • Kim, Yeong-Uk;Sin, Hong-Jae;Ha, Jeong-Min;Choe, Su-Han;Lee, Jong-Gil
    • Korean Journal of Materials Research
    • /
    • v.1 no.1
    • /
    • pp.46-53
    • /
    • 1991
  • The stress of PSG (Phosphosilicate glass), USG (Undoped-silicate grass) and SiN films, which are mainly used as passivation layers in semiconductor memory devices, deposited by CVD methods has been studied as a function of film thickness and holding time in air. The stress of the PSG film or the USG film is increased in tensile state with increasing film thickness. On the other hand the stress level of the SiN film in compressive stress does not change as film thickness changes. The stress of PSG film shows the drastic change from the tensile stress to the compressive stress after the film is left 2 days in air. FTIR spectra indicated that the stress variation was due to the penetration of water molecule. It looks possible to recover the stress of about $2.5{\times}{10^9}dyne/cm^2$ by annealing treatment at $300^{\circ}C$ for 20min. The total stress of multi-layered films having the PSG film is determined mainly by the stress variation of PSG layer with holding time. The total stress of multi-layered film appears to have a functional relationship with the stress in the thickness of each film. The resistance against stress-migration of sputtered Al line increases with increasing the tensile stress for the PSG film or the USG film.

  • PDF

Analysis of the K Gettering in SiO2/PSG/SiO2/Al-1%Si Multilevel Thin Films using SIMS (SIMS를 이용한 SiO2/PSG/SiO2/Al-1%Si 적층 박막내의 K 게터링 분석)

  • Kim, Jin Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.3
    • /
    • pp.219-224
    • /
    • 2017
  • The K gettering in $SiO_2/PSG/SiO_2/Al-1%Si$ multilevel thin films was investigated using SIMS(secondary ion mass spectrometry) and XPS(X-ray Photoelectron Spectroscopy) analysis. DC magnetron sputter techniques and APCVD(atmosphere pressure chemical vapor deposition) were utilized for the deposition of Al-1%Si thin films and $SiO_2/PSG/SiO_2$ passivations, respectively. Heat treatment was carried out at $400^{\circ}C$ for 5 h in air. SIMS depth profiling was used to determine the distribution of K, Al, Si, P and other elements throughout the $SiO_2/PSG/SiO_2/Al-1%Si$ multilevel thin films. XPS was used to analyze binding energies of Si and P elements in PSG passivation layers. K peaks were observed throughout the $PSG/SiO_2$ passivation layers on the Al-1%Si thin films and especially at the $PSG/SiO_2$ interfaces. K gettering in $SiO_2/PSG/SiO_2/Al-1%Si$ multilevel thin films is considered to be caused by a segregation type of gettering. The chemical state of Si and P elements in PSG passivation appears to be $SiO_2$ and $P_2O_5$, respectively

A Study on the Potassium Gettering in Al-1%Si/SiO2/PSG Multilevel Thin Films (Al-1%Si/SiO2/PSG 적층 박막에서 potassium 게터링에 관한 연구)

  • Kim, Jin Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.5
    • /
    • pp.233-237
    • /
    • 2015
  • In order to investigate the potassium (K) gettering, Al-1%Si/$SiO_2$/PSG multilevel thin films were fabricated. Al-1%Si thin films and $SiO_2$/PSG passivations were deposited by using DC magnetron sputter techniques and APCVD (atmosphere pressure chemical vapor deposition), respectively. Heat treatment was carried out at $300^{\circ}C$ for 5 h in air. SIMS (secondary ion mass spectrometry) depth profiling analysis was used to determine the distribution of K, Al, Si, P, and other elements throughout the $SiO_2$/PSG passivated Al-1%Si thin film interconnections. Potassium peaks were observed throughout the $SiO_2$/PSG passivation layers, and especially the interface gettering at the $SiO_2$/PSG and at the Al-1%Si/$SiO_2$ interfaces was observed. Potassium gettering in Al-1%Si/$SiO_2$/PSG multilevel thin films is considered to be caused by a segregation type of gettering.

The Crack Resistance for PSG and Pe-Sin Films in the Semiconductor Device (반도체소자의 표면보호용 PSG, PE-SIN박막의 항균열특성에 대한 연구)

  • Ha, Jung-Min;Shin, Hong-Jae;Lee, Soo-Woong;Kim, Young-Wug;Lee, Jung-Kyu
    • Korean Journal of Materials Research
    • /
    • v.3 no.2
    • /
    • pp.166-174
    • /
    • 1993
  • Abstract The crack resistance of PSG(Phosphosilicate Glass) and PE-SiN(Plasma Enhanced CVD S${i_2}{N_4}$)films deposited on aluminium thin films on Si substrate was analyzed in this study. PSG was deposited by AP-CVD and PE- SiN by PE-CVD. All the films underwent repeated heat cycles at 45$0^{\circ}C$for 30 min. Crack formation and development were examined between each heat cycle. The crack behavior was found to be closely related to the stresses in the films. The stress induced by the difference in thermal expansion behavior between the passivation layers and underlying aluminum film may cause the crack. Crack resistance decreases as the thickness of PSG films increases due to the high tensile stress of the films. Phosphorus in the PSG films releases tensile stress and consequently the stress of the films tends to show compressive stress. As a result, crack resistance increased as the concentratin of P in the PSG films increased. Crack resistance in the PE-SiN films also increased with compressive stress. An experimental model to predict crack generation in the PSG and PE-SiN films during heat cycle was suggested.

  • PDF

Classification of Sleep Stages Using EOG, EEG, EMG Signal Analysis (안전도, 뇌파도, 근전도 분석을 통한 수면 단계 분류)

  • Kim, HyoungWook;Lee, YoungRok;Park, DongGyu
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.12
    • /
    • pp.1491-1499
    • /
    • 2019
  • Insufficient sleep time and bad sleep quality causes many illnesses and it's research became more and more important. The most common method for measuring sleep quality is the polysomnography(PSG). The PSG is a test used to diagnose sleep disorders. The most common PSG data is obtained from the examiner, which attaches several sensors on a body and takes sleep overnight. However, most of the sleep stage classification in PSG are low accuracy of the classification. In this paper, we have studied algorithm for sleep level classification based on machine learning which can replace PSG. EEG, EOG, and EMG channel signals are studied and tested by using CNN algorithm. In order to compensate the performance, a mixed model using both CNN and DNN models is designed and tested for performance.