• Title/Summary/Keyword: PSD2

Search Result 280, Processing Time 0.03 seconds

Real-time position measurements of mobile object using PSD sensor (PSD 센서를 이용한 이동물체의 실시간 위치측정)

  • Ro, Jae-Hee;Kweon, Seok-Geon;Seo, Nam-Il;Ro, Young-Shick
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.540-542
    • /
    • 1998
  • The Position Sensitive Detector(PSD) is an useful device which can be used to measure the position of an incidence light in accuracy and in real-time. In this paper, 2-D PSD sensor is used to measure the 2-D position of moving object with light source. To get the position of light source from PSD sensor exactly, we propose two position computation methods ; the parameter calibration and neural network. Experimental data is presented that offer the comparision between two methods and demonstrates the effectiveness of proposed approach.

  • PDF

A Study of Successful Factor on PSD Application Technique for Manual Operation Mode(ATS) (수동운전(ATS)구간에서 PSD 적용 기술의 성공적 요인 분석연구)

  • Son, Yeong-Jin;Park, Keun-Soo;Min, Kyung-Yun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.755-770
    • /
    • 2006
  • 1974. 8.15 SeoulMetro, beginning with the first electric railway established at six cities, so it is managing mass transportation of traffic. Especially, in case of seoul, It is managing that from one to eight lines, 286.9km, 265 stations have installed and now it is carrying about 5.5million of passengers everyday, and 2,000million passengers a year. So accident is increasing from the station every year. For this measure, SeoulMetro prepares safety fence for passengers crash but, as suicides or people who watch the accident took place, for at the bottom of passengers crash protection, PSD installing is needed. Even though, PSD is managing ATO section but, in controlling SeoulMetro, one to four lines sections are (ATS, ATC)section. Between as ATS, ATC section, ATO section, subway gate and PSD must have opened and crossed always at the time. And the interlock control corrosion protection gate, managing skills with installation, method, using in history, apply to 10rail cars one train sets, and maximum applying 224% sections of passengers congested that consideration is to be needed. So 2004, SeoulMetro improved technology and basic design of PSD at ATS section. Based on this, from 2005.4 to 2006.6, using subway 2lines per 12stations set the model installation(full type 11stations, half type 1station) After installing in case of success, it is going about to suggest that effective analysis and hereafter subject.

  • PDF

Dependence of System Dynamics on Characteristics of Pogo Suppression Device (포고억제장치에 의한 시스템 동특성 변화)

  • Lee Jun Kyoung;Koh Kwang Uoong;Lee Han Ju;Lee Sang Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.121-125
    • /
    • 2004
  • The effectiveness of the pogo suppression device (PSD) installed at the piping system simulating the fuel supply lines of the rocket engines was investigated. The system response defined as the ratio of the flow rate to the pressure in the main tube was obtained for various PSD gas volumes $(0,\;0.5,\;1,\;2\times10^{-6}\;m^3)$. Existence of a gas volume in the PSD reduced the system resonance frequency. With a larger gas volume, the resonance frequency became lower, but only slightly, though the fluctuations of the main tube pressure and the flow rate damped down considerably

  • PDF

A Noticeable Change in Indoor Radon Levels After Platform Screen Doors Installation in Seoul Subway Station (스크린도어 설치 후 서울지하철역 라돈 농도의 변화 특성)

  • Jeon, Jae-Sik;Yoon, Jong-Cheol;Lee, Ho-Chan;Eom, Seok-Won;Chae, Young-Zoo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.59-67
    • /
    • 2012
  • Platform screen doors (PSD) installed at 289 stations in Seoul metropolitan subway from November 2005 to December 2009, are expected to prevent death from a fall and improve air quality. In this study, we systematically surveyed changes in radon concentrations before and after PSD installation in Seoul metropolitan subway stations. By solid-state nuclear track detectors (SSNTD), the radon concentrations before and after the PSD installation were measured at 54 stations of 6 lines from 2 to 7 reported to have relatively high radon concentrations. Mean radon concentrations at platforms were decreased by approximately 56% from 121.7 Bq/$m^3$ to 54.0 Bq/$m^3$. Before PSD installation, mean radon concentrations were in the decreasing order for subway lines 7, 5, 6, 3, 4 and 2. On the other hand, after PSD installation the order was changed to 5, 6, 7, 3, 4 and 2. According to a radon map of Seoul metropolitan subway, the number of platforms where radon concentration over was 74 Bq/$m^3$ decreased from 38 to 12 after PSD installation.

Optical Autofocus System for Wafer Steppers using PSD as the Position Sensor (PSD를 이용한 광학적 자동 촛점장치)

  • 박기수
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.157-161
    • /
    • 1993
  • An optical autofocus system for a DUV KrF excimer laser wafer stepper was developed by using the PSD (Position Sensitive Detector) as the position sensor. The laser beam was incident on the surface of wafer and the reflected beam was magnified optically by a lens. And the beam was directed onto the surface of PSD by a mirror system. The spatial resolution of the autofocus system was found to be $0.03{\mu}m$.

  • PDF

Development of a 3D Motion Capture System with Monocular PSD Camera and Two Active Markers (단안 PSD카메라와 두 능동마커를 이용한 3차원 모션인식 시스템 개발)

  • Seo, Pyeong-Won;Ryu, Young-Kee;O, Chun-Seok
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1025-1026
    • /
    • 2008
  • This paper describes a monocular PSD-based motion capture sensor to employ with commercial video game systems such as Microsoft's XBOX and Sony's Playstation II. The system includes a PSD(Position Sensitive Detector) and active infrared (IR) LED markers that are placed on the object to be tracked. The micro-controller calculates the 3D position of the markers using only the measured intensity and the 2D position on the PSD. A series of experiments were performed to evaluate the performance of our prototype system. From the experimental results we see that the proposed system has the advantages of the compact size, the low cost, the easy installation, and the high frame rates to be suitable for high speed motion tracking in games.

  • PDF

A Study on the Position Compensation of a Mobile Robot Using 2D Position Sensitive Detector (2차원 PSD 를 이용한 이동로보트의 위치 보정에 관한 연구)

  • Ro, Young-Shick;Lee, Ki-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.833-836
    • /
    • 1995
  • The Position Sensitive Detector(PSD) is an useful which can be used to measurement the position of an incidence light in detail and in real-time. In this paper, light sources, to be predefinded positions, are used as landmarks and the 2-D PSD signals are used to compensate the position of a running mobile robot. To induce the position compensation algorithm, first, we inspect the error factor, make the error model, and evaluate the error covariance matrix between the real position and estimated position in dead reckoning system. Next we obtain an optimal position compensation algorithm to update the estimated position using extended Kalman filler by the relation of the external light position and it's PSD signal. Through the simulation of navigating a robot the effectiveness of the proposed method is confirmed.

  • PDF

A study on the optimal ventilation and smoke exhaust systems in case of fire in subway stations installed with PSD (PSD가 설치된 지하철 역사 내 화재 시 최적 배연시스템 연구)

  • Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.527-539
    • /
    • 2018
  • The subway used by many passengers is required to maintain a safe and comfortable environment and PSD (Platform Screen Door) must be installed in the platform after reinforcing the standard in 2003. In the previous research, in case of subway fire to control it, it is necessary to design the optimal ventilation and smoke exhaust system according to equipment capacity of the smoke exhaust system. Therefore, in this study, based on the results of previous research, three-dimensional numerical analysis was performed for the CO gas and smoke flow by the subway ventilation system in case of platform fire. As a result of this study, it was found that in case of emergency, if only the upper-level smoke exhaust system is activated, the risk of evacuation is high due to CO gas (653.8 ppm) and smoke concentration ($768.4mg/m^3$). And when all the smoke exhaust systems are activated and only the fire side PSD is opened, CO gas (36.0 ppm) and smoke concentration ($26.2mg/m^3$) are detected and the propagation range of smoke flow was reduced. When all the smoke exhaust systems are activated and only the fire side PSD is closed, it was analyzed as the most effective ventilation mode in the evacuation environment due to the absence of smoke-recirculation.

A Study of Successful Factor on PSD Application Technique for Manual Operation Mode(ATS) (수동운전(ATS)구간에서 PSD 적용 기술의 성공적 요인 분석연구)

  • Son, Yeong-Jin;Park, Keun-Soo;Min, Kyung-Yun
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.1 s.38
    • /
    • pp.57-66
    • /
    • 2007
  • 1974. 8. 15 SeoulMetro, beginning with the first electric railway established at six cities, so it is managing mass transportation of traffic. Especially, in case of seoul, It is managing that from one to eight lines, 286.9km, 265 stations have installed and now it is carrying about 5.5million of passengers everyday, and 2,000million passengers a year. So accident is increasing from the station every year. For this measure, SeoulMetro prepares safety fence for passengers crash but, as suicides or people who watch the accident took place, for at the bottom of passengers crash protection, PSD installing is needed. Even though, PSD is managing ATO section but, in controlling SeoulMetro, one to four lines sections are (ATS, ATC)section. Between as ATS, ATC section, ATO section, subway gate and PSD must have opened and crossed always at the time. And the interlock control corrosion protection gate, managing skills with installation, method, using in history, apply to 10rail cars one train sets, and maximum applying 2224% sections of passengers congested that consideration is to be needed. So 2004, SeoulMetro improved technology and basie design of PSD at ATS section. Based on this, from 2005.4 to 2006.6, using subway 2lines per 12stations set the model installation(full type 11stations, half type 1station) After installing in case of success, it is going about to suggest that effective analysis and hereafter subject.

Three-Phase Three-Wire Active Power Filter with a Detection Method of Instantaneous Positive Sequence Voltage (정상분 순시전압 검출기법을 이용한 3상 3선 능동전력필터 시스템)

  • 曺 在 延;鄭 榮 國;任 永 徹
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.178-185
    • /
    • 2002
  • This paper describes the implementation of three-phase three-wire active power filter system with a instantaneous PSD for distorted and unbalanced power conditions. The positive sequence voltage of the distorted and the unbalanced power system is calculated by the Instantaneous PSD, and phase transformation matrix of the instantaneous power theory is achieved with detected positive sequence voltage. Finally, the proposed method is experimented and tested under unbalanced nonlinear load as well as unbalanced /distorted condition in power system.