• 제목/요약/키워드: PSD2

검색결과 278건 처리시간 0.032초

2.4GHz 무선 통신을 이용한 PSD 인터페이스 개선에 관한 연구 (A Study on Improvement of PSD Interface Using 2.4GHz Wireless Communication,)

  • 김재필;현용섭;장경송
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1408-1415
    • /
    • 2007
  • To operate Platform Screen Door (PSD) automatically, the operational data of PSD and the train must be interfaced properly. PSD and train are operated together by the signaling system in Automatic Train Operation (ATO) signaling system zone where interfaces are provided between PSD and train. However, the additional PSD interface system with train is required in train operating zone without the interface between PSD and train. For the PSD interface, the wireless communication system or the train status (train correct stop status / train door status) detection system has been used. Seoul Metro line No.2. has the PSD wireless communication system using 447MHz band RF. For the safety of PSD operation, it is required to prevent RF interference in the subway environment where many frequencies exist. In this paper, the PSD wireless communication system is developed using 2.4GHz band RF to prevent the interference of the wireless communication and increase the traffic of the PSD interface. Furthermore, the improved system can store, manage and display the PSD and train operational data using Human Machine Interface (HMI) in the train's driver cab.

  • PDF

일정간격의 두 능동마커를 이용한 저가형 단안 PSD 모션캡쳐 시스템 개발 (Development of a Low-cost Monocular PSD Motion Capture System with Two Active Markers at Fixed Distance)

  • 서평원;김유건;한창호;유영기;오춘석
    • 전자공학회논문지SC
    • /
    • 제46권2호
    • /
    • pp.61-71
    • /
    • 2009
  • 본 논문에서는 가정용 게임에 적용 가능한 저가이면서 컴팩트한 모션캡쳐 시스템을 목표로 하고 있다. 현재 영화나 게임에 이용되는 모션캡쳐 시스템은 장비가 크고 상당히 고가이기 때문에 간단한 가정용 게임에는 적용하기 어렵다. 요즘 흔히 사용되는 USB CCD카메라를 이용한 모션캡쳐 게임은 속도가 느리고 2차원 인식만 하는 단점을 가지고 있다. 하지만 최근 연구에서 저가이면서 속도가 빠른 PSD센서를 이용하여 3차원 측정이 가능한 시스템을 구현할 수 있게 되었다. 2차원 측정이 가능한 PSD센서를 이용한 3차원 모션캡쳐 시스템에는 2개 이상의 PSD를 사용하는 스테레오 비전 기반의 PSD 모션캡쳐 시스템과 빛의 세기와 거리와의 관계를 이용하여 하나의 PSD만으로도 3차원 측정이 가능한 광량보정 기반의 단일 PSD 모션캡쳐 시스템 등이 소개되었다. 하지만 현재 개발된 두 시스템을 가정용 게임에 적용하기에는 다음과 같은 문제가 있다. 두 개 이상의 PSD 센서를 사용해야 하기 때문에 고가이고 복잡하다. 광량보정 기반의 단일 PSD 모션캡쳐 시스템의 경우에는 측정된 마커의 광량을 이용하여 거리를 계산하기 하기 때문에 거리측정을 위해 전방향으로 균일한 광량을 가지는 마커를 만들어야 하므로 매우 어렵다. 따라서 본 논문에서는 이러한 문제를 해결한 새로운 접근방법을 소개하고자 한다. 일정한 거리에 떨어져 있는 두 개의 마커가 광학적 특성만 동일하다면 두 마커 사이의 상대적 광량차이를 이용하여 3차원 측정을 할 수 있다는 것이다. 결과적으로 저가이며, 빠르고, 컴팩트하고, 광각이며, 게임에도 적용가능한 단일 PSD 모션 캡쳐 시스템을 개발했다. 이 개발된 시스템이 애니메이션이나 영화, 게임에도 사용되어질 것으로 기대한다.

포고억제장치 설치에 따른 배관계 동특성 변화 (Change of Piping-System Dynamics with Installation of Pogo Suppression Device)

  • 이준경;이상용;이한주;오승협
    • 한국추진공학회지
    • /
    • 제9권2호
    • /
    • pp.32-39
    • /
    • 2005
  • 액체 연료 로켓의 연료 공급 라인을 모사 한 시스템에 대해, PSD가 시스템의 응답에 미치는 영향을 살펴보았다. 주관의 유량 변화에 대한 주관 압력 변화의 비(시스템 응답)를 PSD 내의 기체 체적$((0\~2)\times10^{-3}m^3)$과 PSD 배플의 직경(5, 50, 115 mm)을 변화시키며 살펴보았다. PSD 내에 기체가 있을 경우, 시스템의 고유진동 주파수가 작아짐을 확인하였다. 그리고 기체의 체적이 클수록 시스템 고유진동 주파수가 작아졌으나, 그 변화는 그리 크지 않았다. 또한 PSD 내 기체량이 많은 경우, 주관 내 압력 및 유량 변화의 진폭이 많이 감소함을 확인할 수 있었다. PSD 배플의 직경이 작아질수록 시스템 고유 진동 주파수가 작아졌으나 그 변화는 작았다. 또한 PSD 배플의 저항이 클 때, PSD 내 압력은 주관의 압력 크기보다 작고, 지연된 파형이 관찰되었다.

Digital n-γ Pulse Shape Discrimination in Organic Scintillators with a High-Speed Digitizer

  • Kim, Chanho;Yeom, Jung-Yeol;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • 제44권2호
    • /
    • pp.53-63
    • /
    • 2019
  • Background: As neutron fields are always accompanied by gamma rays, it is essential to distinguish neutrons from gamma rays in the detection of neutrons. Neutrons and gamma rays can be separated by pulse shape discrimination (PSD) methods. Recently, we performed characterization of a stilbene scintillator detector and an EJ-301 liquid scintillator detector with a high-speed digitizer DT5730 and investigated optimized PSD variables for both detectors. This study is for providing a basis for developing fast neutron/gamma-ray dual-particle imager. Materials and Methods: We conducted PSD experiments using stilbene scintillator and EJ-301 liquid scintillator and evaluated neutron and gamma ray discriminability of each PSD method with a $^{137}Cs$ gamma source and a $^{252}Cf$ neutron source. We implemented digital signal processing techniques to apply two PSD methods - the charge comparison (CC) method and the constant time discrimination (CTD) method - to distinguish neutrons from gamma rays. We tried to find optimized PSD variables giving the best discriminability in a given experimental condition. Results and Discussion: For the stilbene scintillator detector, the charge comparison method and the constant time discrimination method both delivered the PSD FOM values of 1.7. For the EJ-301 liquid scintillator detector, both PSD methods delivered the PSD FOM values of 1.79. With the same PSD variables, PSD performance was excellent in $300{\pm}100keVee$, $500{\pm}100keVee$, and $700{\pm}100keVee$ energy regions. This result shows that we can achieve an effective discrimination of neutrons from gamma rays using these scintillator detector systems. Conclusion: We applied both PSD methods to a stilbene and a liquid scintillator and optimized the PSD performance represented by FOM values. We observed a good separation performance of both scintillators combined with a high-speed digitizer and digital PSD. These results will provide reference values for the dual-particle imager we are developing, which can image both fast neutrons and gamma rays simultaneously.

사물인터넷 기반 초미세먼지(PM2.5) 측정 장치 개발 (Development of IoT-based PM2.5 Measuring Device)

  • 노병국;최기흥
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.21-26
    • /
    • 2017
  • An IoT-based particulate matter (PM2.5) sensing device (PSD) is developed. The PSD consists of a PM2.5 sensor, signal processing circuit, and wi-fi enabled-microprocessor along with temperature and humidity sensors. The PSD estimates PM2.5 density by measuring light scattered by PM2.5. To gauge performance of the PSD, PM2.5 density of open air was measured with the PSD and compared with that of the collocated-government-certified measuring station. Measurements were taken at a sampling frequency of 100 Hz and moving-averaged to remove measurement noise. When compared to the result of the measuring station, average percentile error of PM2.5 density from the PSD is found to be 31%. A correlation coefficient is found to be 0.72 which indicates a strong correlation. Instantaneous variation, however, may far exceed average errors, leading to a conclusion that the PSD is more suitable for estimating average trend of PM2.5 density variations than estimating instantaneous PM2.5 density.

동적 PSD광고 구현을 위한 기술적 제안 : 수도권 지하철 2호선을 중심으로 (The Technical Suggestion for Implementing Animated PSD Ads : Focused on Seoul Metro Line2)

  • 김경주;김석래
    • 디지털융복합연구
    • /
    • 제16권7호
    • /
    • pp.381-391
    • /
    • 2018
  • 본 논문은 지하철 PSD(Platform Screen Door)광고의 효과증진을 위하여, 동적 대상은 정적 대상에 비해 강한 시선 유인 효과를 가진다는 이론적 배경을 전제로, 동적 이미지를 활용한 새로운 형태의 PSD광고를 제안하는 것에 연구의 목적이 있다. 이를 위해 스크린도어와 전동차의 관계 분석을 통해, 효율적인 동적 이미지 구현을 위한, 위치적, 시각적 요소들을 도출하였다. 그 후, 이러한 요소들을 적용한 예시광고를 제작, 3D 프로그램 상에 적용함으로서, 동적 PSD광고의 구현 과정을 확인하였다. 연구결과, 시간차를 이용한 이미지 합성을 통해서 동적 시각효과를 보여줄 수 있는 새로운 형태의 PSD광고 제작이 가능함을 확인할 수 있었고, 이미지들의 조합과 적용에 따라 다양한 시각적 표현이 가능하기에, 본 연구의 제안이 PSD광고라는 광고매체에 다양성을 부여할 수 있음을 또한 확인하였다.

2-체널 링-코어 플럭스-게이트 콤파스의 위상검출 회로 설계와 구현에 관한 연구 (Design and Realization of Phase Sensitive Detector Circuitry of Two-Channel Ring-Core Flux-Gate Compass)

  • 임정빈
    • 한국항해항만학회지
    • /
    • 제26권1호
    • /
    • pp.127-136
    • /
    • 2002
  • 항공 대잠수함전에 사용되는 방향주파수분석저장 소노부위 (DIFAR Sonobuoy)에 방위정보를 제공하는 플럭스-게이트 콤파스의 위상감응검출 (PSD) 회로 설계와 구현에 관해서 기술하였다. PSD 회로는 쌍동-T RC 회로망을 갖는 능동형 대역필터로 구성하였다. PSD 회로에 대한 성능실험 결과, 대역통과 필터가 지구자장 방향에 비례하는 2Fe의 2차 고조파 신호를 효과적으로 걸러냄을 확인하였다. 그 결과 방위 신호 정보를 획득할 수 있었다.

지하철 역사 승강장의 PSD 설치에 의한 미세먼지 감소 효과 (The Removal Effect of Fine Particles Applied Platform Screen Door in Seoul Subway Station)

  • 손종렬;정영림;박현희;오윤희;최원;김순근
    • 환경위생공학
    • /
    • 제24권4호
    • /
    • pp.60-68
    • /
    • 2009
  • The most principal approach to improve indoor air quality(IAQ) of subway was to examine the fine particulate(PM-10) from the emission sources. Therefore, this study was carried on the investigation the fine particulate for comparison with the removal efficiency of PM-10 in divided the PSD(Platform Screen Door) and Non-PSD subway station from July, 2007 to May 2008. In the monitoring results, the range of PM-10 concentration of Non-PSD station was $44.6{\sim}116.5{\mu}g/m^3$ and the range of PM-10 concentration of PSD station was $23.9{\sim}81.1{\mu}g/m^3$. And then the range of PM-2.5 concentration of Non-PSD station was $17.4-56.6{\mu}g/m^3$, and then the range of PM-2.5 concentration of PSD station was $17.9{\sim}34.4{\mu}g/m^3$. In comparison with the results of the PSD and Non-PSD subway station, we found that the PM-10 removal efficiency of PSD was 30-40%. In conclusion, the PSD will be applied the effective facilities of decreasing PM-10 in subway station in Korea.

재가노인의 뇌졸중 후 우울 예측요인 (Predictors of Post Stroke Depression in Community-indwelling Older Adults)

  • 오은미
    • 노인간호학회지
    • /
    • 제20권3호
    • /
    • pp.167-176
    • /
    • 2018
  • Purpose: Post Stroke Depression (PSD) is one of the most common complications for stroke survivors and is associated with negative health outcomes such as disability, death. The purpose of this study was to investigate the prevalence and predictors of PSD among older Korean adults living in the community. Methods: Data collection was done using the 2014 Survey of Living Conditions and Welfare Needs of Korean Older Adults. Participants were 706 older adults who had a stroke. Logistic regression analysis was used to determine the predictors of PSD. Results: The prevalence of PSD which was assessed by the short form of the geriatric depression scale was 49.4%. In a logistic regression model, the predictors of PSD were self-rated health (OR=5.90, CI=3.70~9.40), economic state (OR=2.97, CI=2.07~4.24), independent activities of daily living (IADL) (OR=2.17, CI=1.30~3.63), Activities of Daily Living (ADL) (OR=2.02, CI=1.07~3.80), and education (OR=1.53, CI=1.05~2.24). Conclusion: PSD was common among older Korean adults living in the community. Poor self-rated health status, lower economic state, lower levels of Instrumental Activities of Daily Living (IADL) and ADL, lower levels of education should be considered when conducting activities related to prevention and management of PSD in older adults.

PSD의 출력특성향상을 위한 경사 입력광의 특성해석에 대한 기본연구 (Basic Study of the Improvement of PSD Output by Inclined Light Input)

  • 권현규;박창용
    • 한국기계가공학회지
    • /
    • 제9권4호
    • /
    • pp.53-58
    • /
    • 2010
  • In this paper, the output characteristics of PSD(Position Sensetive Detector) used in measurement system are described. Most of the precision measurment systems are accomplished by a laser diode(LD), a photo diode(PD) and PSD(Position Sensetive Detector), which are used in reflection of mirror or projection of infrared spectrometer. But it is especially restricted by resolution of PD and PSD in nano-measurement. A new inclined light methods into the PSD are employed in the surface measurement system for increasing the resolution. As the results, we can know that the output characteristics of detective senser (PSD) become more than 2 or 3 times by changing inclined angle(range: 5 degree) compared with common angle. In addition, the experiment results are confirmed that the change of inclined angle is not affecting to the linearity and repeating.