• Title/Summary/Keyword: PSD sensors

Search Result 50, Processing Time 0.033 seconds

PSD sensor array design for the 3D measurement of moving objects (이동 물체의 3차원 계측을 위한 PSD 센서 배열 설계)

  • Kim, Jon-Man;Do, Yong-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.106-113
    • /
    • 2008
  • Perceiving a 3D moving target is important for automated machines including robots in a factory. Although stereovision or ultrasonic ranging is often employed for the purpose, the former requires high-cost systems, and the latter suffers from low-resolution. In this paper, we propose a PSD sensor array to acquire the 3D profile of an object conveyed by a belt. Rectangular parallelepiped target objects at random positions and orientations are assumed. Nine PSD sensors are configured in a $3{\times}3$ array above the belt, and fired in a sequence so that cross-talk can be avoided. Time gaps among sensor readings are compensated to get a result that is obtainable when sensors' measurements are made simultaneously along a sensing line. The system designed is tested with various objects in experiments.

Study on Comparing the Performance of Linear CCD sensor with PSD sensor for Distance Measurement (변위측정을 위한 선형 CCD 센서와 PSD 센서의 성능 비교에 관한 연구)

  • Shin, Myung-Kwan;Park, Kyi-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2167-2169
    • /
    • 2004
  • The main concern for a displacement measurement is the performance of a sensor such as speed, resolution, accuracy and so on. The mainly used sensors are a linear CCD(charge coupled device) and a PSD(position sensitive detection) as a non-contact type. The output value of a linear CCD is so sensitive to a temperature change that it needs a cooling device. Additionally, because of its structural problem, there are some limits in resolution and speed, and it needs a complex image processing algorithm. Also, PSD has some disadvantages like sensitivity to environmental lights and nonlinearities. Like this, a linear CCD and PSD have their own characteristics and if we know them well, we can choose the one of the two sensors properly in some applications according to purposes. In this paper, I performed which one is superior to the other among the two sensors in terms of accuracy, resolution, measurement speed, signal to noise ratio.

  • PDF

Development of a Real Time Three-Dimensional Motion Capture System by Using Single PSD Unit (단일 PSD를 이용한 실시간 3차원 모션캡쳐 시스템 개발)

  • Jo, Yong-Jun;Oh, Choon-Suk;Ryu, Young-Kee
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.11
    • /
    • pp.1074-1080
    • /
    • 2006
  • Motion capture systems are gaining popularity in entertainment, medicine, sports, education, and industry, with animation and gaming applications for entertainment taking the lead. A wide variety of systems are available for motion capture, but most of them are complicated and expensive. In the general class of optical motion capture, two or more optical sensors are needed to measure the 3D positions of the markers attached to the body. Recently, a 3D motion capture system using two Position Sensitive Detector (PSD) optical sensors was introduced to capture high-speed motion of an active infrared LED marker. The PSD-based system, however, is limited by a geometric calibration procedure for two PSD sensor modules that is too difficult for common customers. In this research, we have introduced a new system that used a single PSD sensor unit to obtain 3D positions of active IR LED-based markers. This new system is easy to calibrate and inexpensive.

A comparison of the characteristics of External type UHF partial discharge sensor for metal covered barriers in GIS (GIS 스페이서의 에폭시 주입구 장착형 UHF PD 센서의 성능 비교)

  • Hwang, Chul-Min;Kim, Young-No;Lee, Young-Sang;Kwak, Joo-Sik;Park, Ki-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2265-2267
    • /
    • 2005
  • We present detailed studies of externally applicable UHF PD sensors for a metal covered epoxy barrier with a small opening of epoxy injection-hole. The sensors were attached at the surface of injection hole of a metal covered epoxy barrier. 3-Dimensional electro magnetic simulations were performed to analyze electric-field distribution of the GIS and epoxy barrier with injection hole. Sensor structures were designed and analyzed using the 3-D EM simulator then fabricated for experimental verification. Sensor performance was measured in terms of spectral response and detected peak power. Real scale GIS and epoxy barriers were used to test and measure various aspect of performance of the sensors.

  • PDF

The Development of the Condition Monitoring Equipment for distribution Facilities by using the UHF Partial Discharge Sensors (UHF PD 센서를 이용한 배전기기 상태감시장치 개발)

  • Cho, Yong-Jun;Hwang, Chul-Min;Kim, Young-Noh;Choi, Jae-Ok;Song, Il-Keun;Lee, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.406-407
    • /
    • 2008
  • This paper is analyzed the internal type UHF partial Discharge sensors and Condition Monitoring Module that be able to monitor the condition of the distribution facilities. It set the PD cell on the inside of 22.9kV load switchgear and then it executed Partial Discharge test. it introduced the result of the test.

  • PDF

A development of intelligent spacer built in the Internal type UHF partial discharge sensor (초고주파 광대역 부분방전 센서를 내장한 지능형 스페이서 개발)

  • Kim, Dong-Suk;Hwang, Chul-Min;Kim, Young-Noh;Choi, Jae-Ok;Seo, Wang-Byuk;Han, Bong-Soo;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.163-164
    • /
    • 2007
  • In this study, we developed intelligent spacer built in the internal type UHF PD sensors. 3-Dimensional electro-magnetic simulations were performed to analyze electric-field distribution of the single-phase GIS and three-phase GIS. After considering the spacer's specification, Sensor structures were designed and analyzed using the 3-D EM Simulator. As a result of the simulation the internal type UHF PD sensors were built in. Performance of the sensor built into real scale GIS spacer was measured in terms of return loss and detected Max voltage. And we identified a character of the intelligent spacer by using 5pC partial discharge ceil.

  • PDF

Implementation of the SLAM System Using a Single Vision and Distance Sensors (단일 영상과 거리센서를 이용한 SLAM시스템 구현)

  • Yoo, Sung-Goo;Chong, Kil-To
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.149-156
    • /
    • 2008
  • SLAM(Simultaneous Localization and Mapping) system is to find a global position and build a map with sensing data when an unmanned-robot navigates an unknown environment. Two kinds of system were developed. One is used distance measurement sensors such as an ultra sonic and a laser sensor. The other is used stereo vision system. The distance measurement SLAM with sensors has low computing time and low cost, but precision of system can be somewhat worse by measurement error or non-linearity of the sensor In contrast, stereo vision system can accurately measure the 3D space area, but it needs high-end system for complex calculation and it is an expensive tool. In this paper, we implement the SLAM system using a single camera image and a PSD sensors. It detects obstacles from the front PSD sensor and then perceive size and feature of the obstacles by image processing. The probability SLAM was implemented using the data of sensor and image and we verify the performance of the system by real experiment.

Attitude Estimation of a Foot for Biped Robots Using Multiple Sensors (다중 센서 융합을 통한 이족 보행 로봇 발의 자세 추정)

  • Ryu, Je-Hun;You, Bun-Jae;Park, Min-Yong;Kim, Do-Yoon;Choi, Young-Jin;Oh, Sang-Rok
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.586-588
    • /
    • 2004
  • Although stable control algorithm has been implemented to the biped robot, the stability is not guaranteed because of encoder errors and/or rigid body elastics. Hence precise body pose estimation is required for more natural and long term walk. Specially pelvis sloping by gravity or uneven ground on landing place are most critical reason for undulated motion. In order to overcome these difficulties an estimation system for foot position and orientation using PSD sensors and Gyro sensors is proposed along with calibration algorithm and experimental verification.

  • PDF

3D Map-Building using Histogramic In-Motion Mapping in the Eyebot (HIMM을 이용한 3차원 지도작성)

  • 정현룡;김영배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1127-1130
    • /
    • 2003
  • This paper introduces histogramic in-motion mapping for real-time map building with the Eyebot in motion. A histogram grid used in HIMM is updated through three PSD sensors. HIMM makes it possible to make fast map-building and avoid obstacles in real-time. Fast map-building allows the robot to immediately use the mapped information in real-time obstacle-avoidance algorithms. HIMM has been tested on the Eyebot. The Eyebot sends PSD data to computer and computer builds a 3D-Map based on PSD data.

  • PDF

Development of an Intelligent Spacer Built in the Internal type UHF Partial Discharge Sensor (초고주파 광대역 부분방전 센서를 내장한 지능형 스페이서 개발)

  • Kim, Dong-Suk;Hwang, Chul-Min;Kim, Young-Noh;Choi, Jae-Ok;Seo, Wang-Byuk;Han, Bong-Soo;Choi, Soo-Hyun;Jang, Yong-Mu
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1378-1379
    • /
    • 2008
  • In this study, we developed intelligent spacer built in the internal type UHF PD sensors. 3-Dimensional electro-magnetic simulations were performed to analyze electric-field distribution of the single-phase GIS and three-phase GIS. After considering the spacer's specification, Sensor structures were designed and analyzed using the 3-D EM Simulator. As a result of the simulation the internal type UHF PD sensors were built in. Performance of the sensor built into real scale GIS spacer was measured in terms of return loss and detected Max voltage. And we identified a character of the intelligent spacer by using 5pC partial discharge cell.

  • PDF