• 제목/요약/키워드: PSCAD

검색결과 742건 처리시간 0.036초

WFMS 모의를 위한 풍력발전단지 모델 구성 연구 (Study of Wind Farm Model Configuration for WFMS simulation)

  • 김현욱;정승민;황평익;유연태;송성윤;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.247-248
    • /
    • 2015
  • Wind turbines causes instabilities on the grid as their penetration increase. To mitigate harmful effects from wind turbines, transmission system operator(TSO) set up some requirements to obligate for wind generation operator for grid connection. So wind farm management system(WFMS) has important role to follow requirement from TSO, WFMS calculates available real power by considering wake effects, and dispatches real power order to each wind turbine in wind farm to optimize for decreasing load fatigue. To verify operation of WFMS, real-time simulator(RTS) is necessary. This paper deals with RTS configuration to verify WFMS operation. RTS includes wind farm model and power flow code. Normally, wind farm equivalent simple model makes wind turbines in wind farm to one wind turbine mode which cannot verify power flow in wind farm and WFMS operation. Thus, this paper makes wind farm model using simple wind turbine model with transfer function. Matlab is used for make power flow code and wind farm model to impose RTS and those model is certified by PSCAD/EMTDC.

  • PDF

배전시스템에 DC 전력원을 적용하기 위한 제어 기법 설계 (Design of a control scheme for applying DC power sources to a distribution system)

  • 황철상;김경훈;변길성;전진홍;조창희;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1056-1057
    • /
    • 2015
  • A common DC bus is a useful connection for several DC output sources such as photovoltaic (PV), fuel cells, and batteries. Operation of the common DC power system with more than two DC output sources, especially in a stand-alone mode, requires a control scheme for the stable operation of the system. In this paper, a control scheme has been developed for applying DC power sources to the distribution system. The purpose of the control scheme is to make the best use of the DC power sources. The DC power system consists of PV, two energy storage systems and a DC-AC inverter with the control scheme. A distribution system was modeled in PSCAD/EMTDC. As the results, the control scheme is applied to the DC-AC inverter and the DC-DC converter for transfer operations between the grid-connected and the stand-alone mode to keep the DC bus and the AC voltage constant. The results from the simulation demonstrate the stable operation of a grid connected DC power system.

  • PDF

Two Head Vacuum Pump를 이용한 차랑용 산소 발생기 개발 (Development of Oxygen Generator for Vehicle with Two Head Vaccum Pump)

  • 주남규;백규열;차진석;이준배;김남호
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.114-119
    • /
    • 2004
  • 차량이라는 특수한 장소에 적용되는 산소 발생 장치는 소형/경량화 및 소음, 충격, 발열에 대한 문제점을 무시할 수 없다. 이러한 문제점을 해결할 방법으로 BLDC를 이용하여 모터의 발열을 줄이고 합성 제올라이트 NaX형을 사용한 베드로 소형에서도 고농도의 산소를 발생시킬 수 있게 하였다. 또한, 합성 제올라이트 NaX형의 특성으로 인한 질소의 강제 탈착을 진공펌프 한 대로 사용하기 위하여 Two Head 진공펌프 Pump Type을 개발하여 소비 전력을 줄이고 소형/경량화 및 저소음, 충격/발열 문제를 해결할 수 있었다.

연계형 태양광발전설비의 새로운 오동작 방지 및 재병입 알고리즘 제안 (Algorithm for Preventing Malfunction and Reclosing in Grid-Connected PV Systems)

  • 황민수;전태현
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.70-76
    • /
    • 2012
  • In general, the unidirectional power flow is normal in distribution feeders before activation of distributed power source such as PV. However, the interactive power flow is likely to occur in case of the power system under distributed generation. This interactive power flow can cause an unexpected effect on convectional protection coordination systems designed based only on the unidirectional power flow system. When the power line system encounters a problem, the interactive power flow can be a contributed current source and this makes the fault current bigger or smaller compared to the unidirectional case. The effect of interactive power flow is varied depending on the location of the point to ground fault, relative location of the PV, and connection method. Therefore it is important to analyse characteristics of fault current and interactive flow for various transformer connection and location of the PV. This paper proposes a method of improved protection coordination which can be adopted in the protective device for customers in distribution feeders interconnected with the PV. The proposed method is simulated and analysed using PSCAD/EMTDC under various conditions.

D-q Equivalent Circuit-based Protection Algorithm for a Doubly-fed Induction Generator in the Time Domain

  • Kang, Yong-Cheol;Kang, Hae-Gweon;Lee, Ji-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.371-378
    • /
    • 2010
  • Most modern wind turbines employ a doubly-fed induction generator (DFIG) system due to its many advantages, such as variable speed operation, relatively high efficiency, and small converter size. The DFIG system uses a wound rotor induction machine so that the magnetizing current of the generator can be fed from both the stator and the rotor. We propose a protection algorithm for a DFIG based on a d-q equivalent circuit in the time domain. In the DFIG, the voltages and currents of the rotor side and the stator side are available. The proposed algorithm estimates the instantaneous induced voltages of magnetizing inductance using those voltages and currents from both the stator and the rotor sides. If the difference between the two estimated induced voltages exceeds the threshold, the proposed algorithm detects an internal fault. The performance of the proposed algorithm is verified under various operating and fault conditions using a PSCAD/EMTDC simulator.

제주계통의 전압조정을 위한 MMC-HVDC 시스템 응용 (Application of MMC-HVDC System for Regulating Grid Voltage Based on Jeju Island Power System)

  • 왓나우덩;김일환;이도헌;김호찬
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.494-502
    • /
    • 2014
  • This paper presents a control method of the modular multilevel converter - high-voltage direct current (MMC-HVDC) system to regulate grid voltage on the basis of the Jeju Island power system. In this case, the MMC-HVDC system is controlled as a static synchronous compensator (Statcom) to exchange the reactive power with the power grid. The operation of the MMC-HVDC system is verified by using the PSCAD/EMTDC simulation program. The Jeju Island power system is first established on the basis of the parameters and measured data from the real Jeju Island power system. This power system consists of two line-commutated converter - high-voltage direct current (LCC-HVDC) systems, two Statcom systems, wind farms, thermal power plants, transformers, and transmission and distribution lines. The proposed control method is then applied by replacing one LCC-HVDC system with a MMC-HVDC system. Simulation results with and without using the MMC-HVDC system are compared to evaluate the effectiveness of the control method.

독립형 DC 마이크로그리드의 최적화 설계와 협조적 제어 (Optimized Design and Coordinated Control for Stand-alone DC Micro-grid)

  • 한태희;이지헌;김현준;한병문
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.63-71
    • /
    • 2013
  • This paper describes the coordinated droop control method for stand-alone type DC micro-grid to improve reliability and utilization of distributed generations and energy storage. The stand-alone type DC micro-grid consists of several distributed generations such as a wind power generation, solar power and micro-turbine, and energy storage. The proposed method which is based on autonomous control method shows high reliability and stability through coordinated droop control of distributed generations and energy storage and also capability of battery management. The operation of stand-alone type DC micro-grid was analyzed using detail simulation model with PSCAD/EMTDC software. Based on simulation results, a hardware simulator was built and tested with commercially available components and performance of system was verified.

근사레벨제어로 동작하는 중전압 모듈형 멀티레벨 컨버터의 개선된 전압변조기법 (Improved Modulation Scheme for Medium Voltage Modular Multi-level Converter Operated in Nearest Level Control)

  • 김도현;김재혁;한병문
    • 전력전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.285-296
    • /
    • 2017
  • This paper proposes an improved modulation scheme for the medium voltage modular multi-level converter (MMC), which operates in the nearest level control and applies in the medium voltage direct current (MVDC) system. In the proposed modulation scheme, the offset (neutral-to-zero output) voltage is adjusted, with the phase voltage magnitude, thereby maintaining a constant value with N+1 level in the controllable modulation index (MI) range. In order to confirm the proposed scheme's validity, computer simulations for the 22.9 kV - 25 MVA MMC were performed with PSCAD/EMTDC, as well as hardware experiments for the 380 V - 10 kVA MMC. The proposed modulation scheme offers to build a constant pole voltage regardless of the MI value, and to build a phase voltage with improved total harmonic distortion (THD).

철도급전시스템의 고조파 평가를 위한 확률론적 방법 (Probabilistic Method for The Harmonic Analysis of Railroad Feeding System)

  • 이승혁;송학선;이준경;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권9호
    • /
    • pp.384-391
    • /
    • 2006
  • The harmonic currents generated along with the operating speed of electrical railroad traction are very difficult to analyze because of its nonlinear characteristics. This paper therefore presents probabilistic approach for the evaluation of harmonic currents about the operating speed of the arbitrary single traction. To use probabilistic method for railroad system, PDF(Probability Density Function) using measuring data based on the realistic h 따 monic currents per operating speed is calculated. Measuring data of harmonic current per operating speed is obtained using the result data of PSCAD/EMTDC dynamic simulation based on an IAT(Intra Airport Transit) in Incheon International Airport. The means(expected values) and variances of harmonic currents of single traction also are obtained by the PDF of the operating traction speed and harmonic currents. The uncertainty of harmonic currents can be calculated through the mean and variance of PDF. The probability of harmonic currents generated with the operating of arbitrary many tractions is calculated by the convolution of functions. The harmonics of different number of tractions are systematically investigated to assess the TDD(Total Demand Distortion) for the railroad system. The calculation of TDD was carried out using Monte-Carlo Simulations(MSCs) and the results of TDD evaluation of the power quality in the IAT power feeding system.

EMTDC를 이용한 시뮬레이터급 통합전력제어기의 설계 (The Design of UPFC simulator by using EMTDC)

  • 전진홍;송의호;김지원;전영환;김학만;국경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.374-376
    • /
    • 2001
  • FACTS technology is developed into the sophisticated system technology which combines conventional power system technology with power electronics, micro-process control, and information technology. Its objectives are achieving enhancement of the power system flexibility and maximum utilization of the power transfer capability through improvements of the system reliability, controllability, and efficiency[1]. As a series and shunt compensator, UPFC consists of two inverters with common dc link capacitor bank. It controls the magnitude of shunt bus voltage and real and reactive power flow of transmission line[2]. In this paper, we present the design and control algorithm of UPFC simulator for KERI simulator. As a control algorithm is implemented by digital controller, we consider sample-and-hold of signals In this simulation, we use EMTDC/PSCAD V3.0 software which can simulate instantaneous voltage and current.

  • PDF