• 제목/요약/키워드: PROFIBUS

검색결과 63건 처리시간 0.026초

Profibus-DP를 이용한 네트워크 기반 제어 시스템의 원격 퍼지 제어 (Remote Fuzzy Logic Control of Networked Control System Via Profibus-DP)

  • 이경창;이석
    • 제어로봇시스템학회논문지
    • /
    • 제8권4호
    • /
    • pp.281-287
    • /
    • 2002
  • This paper investigates on the feasibility of fuzzy logic control for networked control systems. In order to evaluate its feasibility, a networked control system for motor speed control is implemented on a Profibus-DP network. The NCS consists of several inde-pendent, but interacting processes running on two separate stations. By using this NCS, the network-induced delay is analyzed to find the cause and effect of the delay. Furthermore, in order to prove the feasibility, the fuzzy logic controller's performance is compared with those of conventional PID controllers. Based on the experimental results, the fuzzy logic controller can be a viable choice far NCS due to its robustness against parameter uncertainty.

엄격한 실시간 요구조건을 만족하는 무선 확장 Profibus의 개발 (Development of Wireless Extended Profibus with Hard Real-time Requirement)

  • 이경창;김도형;이석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.586-589
    • /
    • 2001
  • This paper focuses on a method to connect mobile devices such as mobile robot, Automated Guided Vehicle(AGV) to a fieldbus. In this paper, the IEEE 802.11 wireless LAN is used to extend a Profibus-DP network for the mobile devices. In order to integrate these two networks, a protocol converter is developed with two process(i.e., master process of Profibus-DP and virtual master process of IEEE 802.11) and an transmission buffer. Futhermore, a virtual polling algorithm is developed at the protocol conveter in order to satisfy real-time requirements on data communication.

  • PDF

Profibus 성능 모델에서 최대 허용 전송 지연을 만족할 수 있는 타이머 선정에 관한 연구 (Timer Selection for Satisfying the Maximum Allowable Delay using Performance Model of Profibus Token Passing Protocol)

  • 김현희;이경창;이석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.181-184
    • /
    • 2003
  • Recently, the fieldbus becomes an indispensable component for many automated systems. In the fieldbus system, realtime data containing sensor values and control commands has a tendency to rapidly lose its value as time elapses after its creation. In order to deliver these data in time, the fieldbus network should be designed to have short delay compared to the maximum allowable delay. Because the communication delay is affected by performance parameters such as target rotation timer of token passing protocol, it is necessary to select proper parameter settings to satisfy the real-time requirement for communication delay. This paper presents the timer selection method for Profibus token passing networks using genetic algorithm (GA) to meet the delay requirements.

  • PDF

Implementation of Networked Control System using a Profibus-DP Network

  • Lee, Kyung-Chang;Lee, Suk
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권3호
    • /
    • pp.12-20
    • /
    • 2002
  • As numerous sensors and actuators are used in many automated systems, various industrial networks are adopted for real-time distributed control. In order to take advantages of the networking, however, the network implementation should be carefully designed to satisfy real-time requirements considering network induced delays. This paper presents an implementation scheme of a networked control system via Profibus-DP network fur real-time distributed control. More specifically, the effect of the network induced delay on the control performance is evaluated on a Profibus-DP testbed. Also, two conventional PID gain tuning methods are slightly modified fur fouling controllers fur the networked control system. With appropriate choices for gains, it is shown that the networked control system can perform almost as well as the traditional control system.

Profibus 토큰 패싱 프로토콜 성능 모델에서의 전송 지연 특성 (Communication Delay Properties in Performance Model of Profibus Token Passing Protocol)

  • 이경창;김현희;이석
    • 제어로봇시스템학회논문지
    • /
    • 제9권12호
    • /
    • pp.1055-1064
    • /
    • 2003
  • In many automated systems, such as manufacturing systems and process plants, a fieldbus is a very important component for the exchange of various and sometimes crucial information. Some of the information has a tendency to rapidly lose its value as time elapses after its creation. Such information or data is called real-time data that includes sensor values and control commands. In order to deliver these data in time, the fieldbus network should be tailored to have short delay with respect to the individual time limit of various data. Fine-tuning the network for a given traffic requires the knowledge on the relationship between the protocol parameters such as timer values and the performance measure such as network delay. This paper presents a mathematical performance model to calculate communication delays of the Profibus-FMS network when the timer value and the traffic characteristics are given.

필드버스를 이용한 생산자동화 시스템 구축 기술 연구 (A Study on the Implementation of Fieldbus-Based Manufacturing Automation Systems)

  • 홍승호;박태진
    • 한국정밀공학회지
    • /
    • 제16권3호통권96호
    • /
    • pp.91-102
    • /
    • 1999
  • Fieldbus provides real-time data communication among field devices in the manufacturing automation and process control systems. In this study, an experimental model of fieldbus-based manufacturing automation system is developed. Experimental model consists of two robots, two conveyor belts, NC machine, PLC, sensors and operator station. These machines are interconnected into the Profibus network, and exchange their data through the services provided by FMS(Fieldbus Message Specification), which is the application layer protocol of Profibus. The experimental model is used to measure the network-induced delay of variable and file data transmitted through FMS services. Network-induced delays are collected and analyzed on each sublayer of Profibus protocol stack. The results obtained from the experiment of this study can be effectively utilized when fieldbus is implemented on the practical manufacturing automation systems.

  • PDF

Implementation of Simple and Intelligent Slave ASIC for Profibus-DP

  • Kwon, Dae-Hyun;Bae, Gyu-Sung;Lee, Young-Joon;Lim, Kye-Young;Moon, Jeong-Il;Kim, Jong-Bae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.77.2-77
    • /
    • 2001
  • Profibus-DP is the performance-optimized version of Profibus, specifically dedicated to time-critical communication between automation systems and distributed peripherals. It is included into the International Fieldbus Standard IEC 61158. In this paper, The ASIC for Profibus-DP simple and intelligent slave is proposed and implemented. It can be fully compatible with Siemens LSPM2 as a pin-to-pin base and it also has a high-level function that can replace current intelligent slave boards with one chip. Also it can be used without special OS coding unlike SPC3 of Siemens.

  • PDF

On-line Fussy Performance Management of Profibus Networks

  • Lee, Kyung-Chang;Song Kang;Kim, Dong-Wook;Lee, Suk
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제1권2호
    • /
    • pp.5-13
    • /
    • 2000
  • Most networks for automation are tuned to an expected traffic condition ar their design stage. During their actual operations, however, the networks experience considerable changes in traffic from time to time. These traffic changes caused by common events like machine failure and production schedule change may adversely affect th network performance and, in turn , the performance of the connected devices. This paper presents experimental results for performance management of a Profibus-FMS network. The performance management aims to maintain a uniform level of network performance at all stations under changing network traffic. The performance management algorithm monitors the performance of individual network stations and commands the stations to change their timer values in order to have comparable performance at all stations. In order to determine the amount of timer change, the algorithm employs a set of fuzzy rules. The algorithm has been evaluated on a Profibus network.

  • PDF

PROFIBUS 토큰 패싱 프로토콜의 성능모델에서의 전송지연 특성 (Communication Delay Properties in Performance Model of PROFIBUS Token Passing Protocol)

  • 김현희;이경창;이석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.511-514
    • /
    • 2002
  • In may automated systems such as manufacturing systems and process plants, an industrial network or fieldbus is a very important component for the exchange of various and sometimes crucial information. Some of the information has a tendency to rapidly lose its value as time elapses after its creation. Such information or data is called real-time data that includes sensor values and control commands. In order to deliver these data in time, the fieldbus network should be tailored to have short delay with respect to the individual time limit of various data. Fine-tuning the network for a given traffic requires the knowledge on the relationship between the protocol parameters such as timer values and the performance measure such as network delay. This paper presents a mathematical performance model to calculate communication delays of the Profibus FMS network when the timer value TTR and the traffic characteristics are given. The results of this model is compared to those from experiments to assess the model's validity.

  • PDF

Profibus와 인버터를 이용한 공기량 제어시스템 구현 (A Study on the Implementation of Air flow Control System using Profibus and Inverter)

  • 문용선;이명복;김동권;정철호
    • 제어로봇시스템학회논문지
    • /
    • 제9권10호
    • /
    • pp.808-815
    • /
    • 2003
  • Fieldbus technology is having a massive impact on the development of faster, smarter and less expensive industrial networking systems. However, there have been a few of practically applied cases and channels for obtaining technical advices. Moreover, the users in the industry don't trust the Fieldbus technology like they didn't trust PLC control system in 1970s. Therefore, in this paper, Air flow control system is constructed by Fieldbus technologies, Profibus and Inverter that controls the motor speed. With the features of the motor control, the amount of electric power consumption by the speed control of motor is measured by the constructed control system. From this measured result, the effectiveness of the airflow control system and Feasibility to the practical industry field is demonstrated To improve the confidence of Fieldbus technology, practically embodied cases and technical methods are presented.