• Title/Summary/Keyword: PPLN

Search Result 48, Processing Time 0.029 seconds

Changes of Triglyceride Composition in Adlay Powder during Storage (율무가루 저장 중 Triglyceride 조성의 변화)

  • Han, Ji-Sook;Rhee, Sook-Hee;Cheigh, Hong-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.102-108
    • /
    • 1991
  • Raw adlay powder(RAP)was prepared and the changes of triglyceride composition in RAP lipid during storage at $35^{\circ}C$ for six months were studied. The RAP lipid consisted of 28 kinds of triglycerides and the major triglyceride in RAP lipid were those of OOL(24.14%), OLL(24.06%), OOO(12.58%), POL(9.01%), POO(8.87%), LLL(7.91%)and PLL(5.80%). During the storage at $35^{\circ}C$ for six months, the relative amounts of the triglyceride containing linoleic acid(OLL : 15.25%, LLL : 2.93%)considerably decreased, but those containing oleic acid(OOO : 23.77%. POO : 12.62%) increased. The triglycerides of LLA(0.44%)and PPLn(0.12%)disappeared during the storage.

  • PDF

Compact green light sources for laser projection display

  • Ko, Do-Kyeong;Jung, Chang-Soo;Yu, Nan-Ei;Yu, Bong-Ahn;Lee, Yeung-Lak;Lee, Jong-Min
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1335-1336
    • /
    • 2008
  • A compact diode-pumped microchip(DPM) green light source which consist of pump LD, $Nd:YVO_4$, KTP and a built-in thermoelectric element has been fabricated for laser projection display. The volume of the source is as small as $0.7\;cm^3$ and we obtained the output power of 25mW with the average electric power consumption in pump LD of 304mW which correspond to the electrical-to-optical efficiency of 7.8%. Another approach using quasi phase matching(QPM) technique has been attempted. We obtained the output power of 90mW of green beam with 350mW pumping of a $Nd:YVO_4$ laser with 20-kHz rep. rate and 10-ns pulse duration. Detailed characteristics and issues of the DPM and QPM green light sources will be addressed.

  • PDF

Characteristics of output for optical parametric oscillation in periodically poled $LiNbO_3$ pumped by dioded-pumped Nd:YAG laser (다이오드 펌프 Nd:YAG 레이저로 펌프된 주기적 분극 반전된 $LiNbO_3$ OPO의 출력 특성)

  • 조기호;이범구
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.68-69
    • /
    • 2003
  • Quasi-Phase-Matching(QPM)을 이용한 Optical Parametric Oscillation(OPO)은 높은 효율과 작은 Walk-off 효과를 보인다는 장점을 가지고 있다. 그러나 작은 펌프빛의 크기로 인한 빛세기의 증가는 optical damage와 photorefractive effect 야기하고, 이러한 요인으로 안정적인 고출력 연속발진에 있어서는 그 한계가 있으리라고 생각되어진다. 본 연구에서는 주기가 27.7 $mu extrm{m}$인 Periodically poled LiNbO$_3$(PPLN)을 비선형매질로 이용하여 10 kHz의 고반복률을 갖는 다이오드 펌프 Nd:YAG 레이저에서의 Quasi-Phase-Matched Optical Parametric Oscillation의 Signal파의 출력특성 및 안정화에 대하여 조사를 하였다. (중략)

  • PDF

Frequency Tuning Characteristics of a THz-wave Parametric Oscillator

  • Li, Zhongyang;Bing, Pibin;Xu, Degang;Yao, Jianquan
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.97-102
    • /
    • 2013
  • Frequency tuning characteristics of a THz-wave by varying phase-matching angle and pump wavelength in a noncollinear phase-matching THz-wave parametric oscillator (TPO) are analyzed. A novel scheme to realize the tuning of a THz-wave by moving the cavity mirror forwards and backwards is proposed in a noncollinear phase-matching TPO. The parametric gain coefficients of the THz-wave in a $LiNbO_3$ crystal are explored under different working temperatures. The relationship between the poling period of periodically poled $LiNbO_3$ (PPLN) and the THz-wave frequency under the condition of a quasi-phase-matching configuration is deduced. Such analyses have an impact on the experiments of the TPO.

Ferroelectric domain inversion in $LiNbO_3$ crystal plate during heat treatment for Ti in-diffusion ($Ti:LiNbO_3$ 도파로 제작을 위한 열처리 과정 동안 강유전 도메인 특성에 미치는 영향)

  • Yang, W.S.;Lee, H.Y.;Kwon, S.W.;Kim, W.K.;Lee, H.Y.;Yoon, D.H.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.15 no.3
    • /
    • pp.124-127
    • /
    • 2005
  • It is demonstrated that the annealing process for Ti in-diffusion to z-cut $LiNbO_3$ at temperature lower than the curie temperature in a platinum (Pt) box can cause a ferroelectric micro-domain inversion at the +z surface and Li out-diffusion, therefore which should be avoided or suppressed for waveguide type periodically poled lithium niobate (PPLN) devices. The depth of the inversion layer depends on the Ti-diffusion conditions such as temperature, atmosphere, the sealing method of $LiNbO_3$ in the Pt box and crystal orientation is experimentally examined. The result shows that the polarization-inverted domain boundary appears at the only +z surface and its thickness is about $1.6{\mu}m$. Also, for the etched $LiNbO_3$, surface the domain shape was observed by the optical microscope and atomic force microscopy (AEM), and distribution of the cation concentrations in the $LiNbO_3$ crystal by the secondary ion mass spectrometry (SIMS).

Linewidth Reduction of a Yellow Laser by a Super-cavity and the Measurement of the Cavity Finesse (초공진기를 이용한 노란색 레이저의 선폭 축소 및 초공진기의 예리도 측정)

  • Lee, Won-Kyu;Park, Chang-Yong;Park, Sang-Eon;Ryu, Han-Young;Yu, Dai-Hyuk;Mun, Jong-Chul;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.3
    • /
    • pp.123-128
    • /
    • 2010
  • Sum frequency generation was utilized to obtain a yellow laser with the wavelength of 578.4 nm for a probe laser of an Yb lattice clock. The output of an Nd:YAG laser with wavelength of 1319 nm and that of an Yb-fiber laser with wavelength of 1030 nm were passed through a waveguided periodically-poled lithium niobate (WG-PPLN) for sum frequency generation. It is required that the probe laser has a linewidth of the order of 1 Hz to fully resolve the Yb lattice clock transition. Thus, the linewidth of the probe laser was reduced by stabilizing the frequency to a super-cavity. This was made of ULE with a low thermal expansion coefficient, and was mounted on an active vibration-isolation table at the optimal point for the reduced sensitivity to vibration. Also, this was installed in a vacuum chamber, and the temperature was stabilized to 1 mK level. This system was installed in an acoustic enclosure to block acoustic noise. The finesse of the super-cavity was measured to be 380 000 from the photon life time of the cavity.

Performance Evaluation of Mid-IR Spectrometers by Using a Mid-IR Tunable Optical Parametric Oscillator (중적외선 광 파라메트릭 발진기를 이용한 중적외선 분광기 성능 평가)

  • Nam, Hee Jin;Kim, Seung Kwan;Bae, In-Ho;Choi, Young-Jun;Ko, Jae-Hyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.4
    • /
    • pp.154-158
    • /
    • 2019
  • We have used a mid-IR (mid-infrared) continuous-wave (cw) optical parametric oscillator (OPO), developed previously and described in Ref. 12, to build a performance-evaluation setup for a mid-IR spectrometer. The used CW OPO had a wavelength tuning range of $ 2.5-3.6{\mu}m$ using a pump laser with a wavelength of 1064 nm and a fan-out MgO-doped periodically poled lithium niobate (MgO:PPLN) nonlinear crystal in a concentric cavity design. The OPO was combined with a near-IR integrating sphere and a Fourier-transform IR optical spectrum analyzer to build a performance-evaluation setup for mid-IR spectrometers. We applied this performance-evaluation setup to evaluating a mid-IR spectrometer developed domestically, and demonstrated the capability of evaluating the performance, such as spectral resolution, signal-to-noise ratio, spectral stray light, and so on, based on this setup.

Single-photon Detection at 1.5 ㎛ Telecommunication Wavelengths Using a Frequency up-conversion Detector (주파수 상향변환 검출기를 이용한 1.5 ㎛ 통신파장대역의 단일광자 측정)

  • Kim, Heon-Oh;Youn, Chun-Ju;Cho, Seok-Beom;Kim, Yong-Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.5
    • /
    • pp.223-229
    • /
    • 2011
  • We present a low jitter frequency up-conversion detector based on quasi-phase matched sum frequency generation in a periodically poled $LiNbO_3$ waveguide for efficient single-photon detection at 1.5 ${\mu}m$ telecommunication wavelengths. The maximum detection efficiency and the noise count rate using the pump power of 300 mW and the pump wavelength of 974 nm are about 7% and 480 kHz, respectively. We also characterize the timing jitter of the frequency up-conversion detector by analyzing the time distribution of the detection outputs for photons generated through a picosecond pump pulsed spontaneous parametric downconversion. The minimum timing jitter was measured to be about 39.1 ps. Coincidence measurement with a narrow time window for pulsed up-conversion photons can eliminate the unwanted noise counts and maximize signal to noise ratio.