• Title/Summary/Keyword: PPD(Predicted Percentage Dissatisfied)

Search Result 20, Processing Time 0.018 seconds

Determining thermal comfort properties of coverall worn in the atomic power plant using a sweating thermal manikin and ISO 7730 (발한 Thermal manikin과 국제 표준 7730을 이용한 원자력 발전소 작업복의 열적 쾌적성 판별)

  • 홍성애
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.91-103
    • /
    • 1996
  • For determining thermal comfort properties of work suit in an atomic power plant, three different coverall ensembles (PVE, PET/Rayon, PP Nonwoven) were selected and the resistance to dry and evaporative heat transfer were measured for each ensemble by using a sweating thermal manikin. Also, PMV (Predicted Mean Vote) and PPD(Predicted Percentage of Dissatisfied) indices were predicted according to ISO 7730. As a result, ideal environmental conditions in an atomic power plant were suggested to make workers feel thermally comfortable. In addition, ideal intrinsic insulation values of coverall ensembles as a work suit under the present environmental conditions in the at6omic power plant were provided. The information given in this paper can be used to control environmental conditions in the atomic power plant thermally comfortable and to select a proper work suit for providing thermal comfort to the workers.

  • PDF

An Study on the Evaluation of Thermal Indoor Environment and Thermal Sensations during Winter and Summer in Elderly Welfare Facilities (老人福祉施設의 冬.夏節期 室內 溫熱環境 測定 및 溫熱感 評價)

  • Kwak, Ho;Ryoo, Woo-Dong;Hwang, Kwang-Il;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.14 no.1
    • /
    • pp.19-27
    • /
    • 2003
  • This study aims to survey the living spaces of the welfare facilities for the aged to get the objective relationships between the physical thermal environment and the users' subjective responses. The surveys were made twice in winter and once in summer during 2001 and 2002. An ambient temperature, relative humidity, air velocity, globe temperature were measured as physical elements of thermal environment and the ASHRAE Psychophysical Voting Scale were used as an evaluation index for subjective responses. As the results, the aged respond thermally comfortable, in spite of the differences among important factors such as thermal sensations, humidity sensations and air velocity sensations. Also the physical thermal environmental elements and the subjective responses indices exceed thermal comfort range calculated by PMV(Predicted Mean Vote) and PPD(Predicted Percentage Dissatisfied). It shows that the insulation of walls of the facilities is not enough for heating and cooling seasons, and the indoor environmental control is necessary.

Computer Simulation on the Thermal Environment by the Diffusion temperature and Diffusion Angle of Ceiling Type Air Conditioner in Classroom (교실에서의 천장형 냉난방기의 취출온도 및 취출각도에 따른 열환경 시뮬레이션)

  • Park, Hyo-Soon;Park, Seung-Ik;Lee, Sang-Hyeok;Lee, Kam-Gyu
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.4 no.4
    • /
    • pp.1-18
    • /
    • 2004
  • Research has been carried out to study thermal environment in a classroom under three kinds of air diffusion temperature and six kinds of air diffusion direction for ceiling type air conditioner. The velocity and temperature distributions of air in the room calculated by 3-dimensional numerical method(PHOENICS), This present study was also conducted to calculate the Air Diffusion Performance Index(ADPI) for cooling conditions and Predicted Percentage of Dissatisfied(PPD) for heating conditions. This analysis shows that the optimum angle of ceiling type air conditioner's diffusion is $15{\sim}30^{\circ}$ for cooling mode and about $15{\sim}45^{\circ}$ for heating mode in these calculating conditions. And also analysis has been carried out to evaluate thermal comfort of vertical and horizontal cross section of classroom.

  • PDF

Diffusion Simulation Using Envi-Met. in Urban Planetary Boundary Layer (Envi-Met.을 이용한 도심 대기경계층 내 확산장 변화 수치 모의)

  • Choi, Hyun-Jeong
    • Journal of Climate Change Research
    • /
    • v.7 no.3
    • /
    • pp.357-371
    • /
    • 2016
  • Buildings in the city acts as a cause of distorted wind direction, wind speed, causing the stagnation of the air flow. In the recent trend of climate change can not but consider the temperature rise of the urbanization. This study was aimed to analyze the thermal comfort of planetary boundary layer in different artificial constructions areas which has a direct impact on urban climate, and estimating the warming phenomena. Envi-met model was used to consider the urban structure associated with urban growth in order to precisely determine the impact of the building on the city weather condition. The analyzed values of thermal comfort index were temperature, wind speed, horizontal and vertical turbulent diffusivity. In particular, analysis of the PPD(Predicted Percentage of Dissatisfied) represents the human thermal comfort. In this study, by adjusting the arrangement and proportion of the top floor building in the urban it was found that the inflow of the fresh air and cooling can be derived low PPD. Vertical heat flux amount of the city caused by climate change was a factor to form a high potential temperature in the city and the accumulation of cold air does not appear near the surface. Based on this, to make the city effectively respond to climate change may require a long-term restructuring of urban spatial structure and density management.

Effect of the Vertical Air Circulation on the Thermal "Environment in a Large Space (대공간 열환경 특성에 관한 수직순환기류의 영향)

  • 김경환;강석윤;최충현;조영진;이재헌;오명도
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.581-588
    • /
    • 2000
  • This paper describes the effect of vertical air circulation on the thermal environment in an airport passenger terminal with induced flow by jet fans. In comparing the level of thermal comfort at the breathing line of 1.5 m in height, the results from the two models with or without the vertical air circulation, show that the average PPD is 8% in the former and 23% in the latter, respectively. It is thought that vertical air circulation lends to improved thermal comfort for human in respect of ventilation in a large space.

  • PDF

The Effect of Tree Density of Pinus koraiensis Forest on the Thermal Comfort and the Physiological Response of Human Body in Summer Season (잣나무림의 입목밀도가 여름철 온열환경 및 인체 생리반응에 미치는 영향)

  • Park, Bum-Jin;Kyeon, Chiwon;Choi, Yoonho;Yeom, Dong-geol;Kim, Geonwoo;Joung, Dawou
    • Journal of Korean Society of Forest Science
    • /
    • v.104 no.2
    • /
    • pp.261-266
    • /
    • 2015
  • This study was conducted to examine the effect of tree density of Pinus koraiensis forest on the thermal comfort and the physiological response of human body in summer season. As the indicators of thermal comfort were used the predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), while the heart rate variability was used for the physiological indicator of subjects. The subjects were 15 physically healthy men and women in their 20s ($23.7{\pm}1.7$ years old). The subjects sat in each site to measure HRV for 5 minutes and the thermal comfort of each site was measured. As a results, it was proven by PMV and PPD that the Pinus koraiensis forest with 120% tree density was thermally more comfortable than the Pinus koraiensis forest with 80% tree density. In case of the subjects' physiological response, the Pinus koraiensis forest with 120% tree density showed significantly higher HF of HRV than the Pinus koraiensis forest with 80% tree density and significantly lower LF/HF. Therefore, the findings of this study scientifically proved that the Pinus koraiensis forest with 120% tree density is thermally more comfortable and physiologically more relaxing than the Pinus koraiensis forest with 80% tree density.

Analysis of a forest healing environment based on the thermal comfort and NVOC characteristics of Chungnam National University Experimental Forests

  • Hyelim Lee;Dawou Joung;Siok An;Doyun Song;Bum-Jin Park;Seungmo Koo
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.4
    • /
    • pp.983-993
    • /
    • 2022
  • The purpose of this study is to provide information on a forest healing environment using the analysis of nature volatile organic compounds (NVOCs) and thermal comfort in Chungnam National University Experimental Forest, with the aim of using the Experimental Forest as a healing environment for health promotion. We analyzed NVOCs and thermal comfort of Chungnam National University Experimental Forest measured on September 12th, 2021. As a result of the NVOC analysis, a total of seven substances were detected, mainly including alpha pinene and beta pinene. The detection amount for each time period was highest at the time of sunset. The thermal comfort was analyzed by time-dependent changes and changes according to clothing and exercise amount. The results showed that the predicted mean vote of the experimental forest is within the range of 'slightly cool' and 'slightly warm' sensation, and thus a comfortable thermal environment could be controlled by the amount of clothing and activity. Based on the analysis, this study provides information on the healing environment of the experimental forest at Chungnam National University. It also indicates that the forest can be used as a health promotion and healing environment with thermal comfort by composing a physical activity program of appropriate intensity for each time period.

A Numerical Study of Automotive Indoor Thermal Comfort Model According to Boarding Conditions and Parameters Related to HVAC (HVAC 관련 매개변수 및 탑승조건에 따른 자동차 실내의 온열쾌적성 평가모델에 관한 수치해석적 연구)

  • Yoon, Seong Hyun;Park, Jun Yong;Son, Deok Young;Choi, Yunho;Park, Kyungseok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.9
    • /
    • pp.979-988
    • /
    • 2014
  • Recently, the interest in the thermal comfort is ever increasing as the time people stay in the automobile is gradually increasing. So far, however, the cooling performance of the HVAC(heating and ventilation air conditioning) system is evaluated by thermal environment criteria such as indoor air velocity and temperature, not by a thermal comfort index. Furthermore, the precise criteria has not been established yet when the thermal comfort for the automobile is evaluated using numerical analysis. In this study, the numerical analysis of automobile indoor thermal comfort according to various parameters such as HVAC operating mode, airflow, passenger boarding conditions is performed during the HVAC system's initial operating time(20 minutes). The solar ray tracing model and S2S radiation model are used and validated to simulate an external heat source. Based on this study, an evaluation model which can predict the thermal comfort index for the combination of the above parameters is presented.

Temporal Changes in the Physiological and Psychological Relaxation Effects of a Forest Environment during the Summer (시간 변화에 따른 여름철 산림환경의 생리ᐧ심리적 안정 효과)

  • Injoon Song;Juhyeon Kim;Choyun Kim;Dawou Joung;Yunjeong Yi;Bum-Jin Park;Chorong Song
    • Journal of Korean Society of Forest Science
    • /
    • v.113 no.1
    • /
    • pp.107-117
    • /
    • 2024
  • This study investigated temporal changes in forest physical variables and their effects on thermal comfort and physiological and psychological responses. Environmental factors (air temperature, mean radiant temperature, wind speed, and relative humidity), the predicted mean vote (PMV), and the predicted percentage of dissatisfied (PPD) visitors were continuously measured between 9:00 AM and 6:00 PM. We assessed the physiological and psychological responses (heart rate variability, heart rate, oral temperature, blood pressure, pulse rate, thermal sensation vote, comfort sensation vote, and subjective feelings) of 30 male university students (average age: 21.7±1.9 years), who closed their eyes and relaxed for 5 minutes every hour. Examination of correlations between environmental factors and physiological responses showed that ① the mean radiant temperature, wind speed, and relative humidity significantly changed with time; ② PMV and PPD also showed significant changes over time, and the thermal sensation vote corresponded with PMV; however, the comfort sensation vote did not correspond with PPD; ③ Among the physiological responses, parasympathetic nerve activity, sympathetic nerve activity, heart rate, and diastolic blood pressure significantly varied with time, with parasympathetic nerve activity having the lowest value and sympathetic nerve activity the highest at the highest air temperature (2:00-4:00 PM); and ④ Air temperature, mean radiant temperature, and wind speed showed a negative correlation with parasympathetic nerve activity and a positive correlation with sympathetic nerve activity. These findings indicate that the relaxation effects of the forest environment depend on what time of day people are exposed to it, and the changes occurring in forest environmental factors over time modulate these effects.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.