• Title/Summary/Keyword: POLLUTANTS

Search Result 4,232, Processing Time 0.031 seconds

Investigation of the Environment for Conservation in the Facilities of Exhibition and Collection for Cultural Properties (문화재 전시 및 수장시설 내에서의 보존환경 조사연구)

  • Hong, Jung-Ki;Kim, Sa-Dug;Kim, Soon-Kwan;Kang, Dai-Ill;Lee, Myeong-Hui
    • 보존과학연구
    • /
    • s.22
    • /
    • pp.155-171
    • /
    • 2001
  • The facilities of exhibition and collection for cultural properties is affected by environmental pollution. In order to accumulate a store of basic data, we was investigated eight points(three points at exhibition room and five points at collection room) at four institutes, from December 2000 to March 2001.As a result of investigation, the temperature of A-Exhibition room measured low because of don’t moved HVAC(Heating, Ventilation and Air-Conditioning) System, B Exhibition room is dry for the effect of air-conditioner and the air pollutants concentration of C-Exhibition room is high for the kind of an exhibition room. The air-condition was varied within the open period. The air pollutants concentration of A-Collection room is measured high because the air-pollutants is generated in a new buildings and the air pollutants concentration of C-1 & C-2-Collection room is high for the kind of an collection room. It is necessary to ventilate sufficiently.

  • PDF

Effects of Detergent and other Pollutants related Domestic Sewage on Water Pollution (세제 및 생활하수 관련 오염성분이 수질오염에 미치는 영향)

  • Kim, Mann-Young;Choi, Ung-Su;Kim, Jae-Yong;Kim, Kwang-Ryul
    • Applied Chemistry for Engineering
    • /
    • v.4 no.3
    • /
    • pp.564-568
    • /
    • 1993
  • By measuring the COD (chemical oxygen demend) of dish washing detergents being sold at market and pollutants connected with domestic sewage, we compared the amounts of water pollutants of one with other and carried out the experiments of ultimate biodegradation as against these samples. Also we combined our experimental results and circumstances of water pollution and wastewater treatments to the sewage system, compared the effects of synthetic detergent on water pollution with soap and the other pollutants and investigated results of our research.

  • PDF

Treatment of non-degrable Organic Pollutants in Aqueous by ultrasonic irradiation (초음파에 의한 수중의 난분해성 오염물질 처리)

  • 손종열;모세영;손진석
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.76-84
    • /
    • 1995
  • This study was performed to examine the factors influenced on the decomposition of nondegradable organic pollutants( Tricholoroethylene,Benzene ) in aqueous by ultrasonic irradiation. The TCE( Tricholoroethylene ) and Benzene are major hazard compounds causing environmental Pollution and not decomposable substances by conventional treatment. The results shows that the oxidation and reduction reaction of ultrasonic Irradiation was formed the H$_{2}$O$_{2}$ , H$^{+}$ and OH$^{-}$ radical, and then theses was decomposed pollutants of TCE and Benzene in aqueous. We were conformed that the ultrasonic irradiation was excellent in removal efficiency of the nondegradable organic substances any other than processes and utilized the treatment of organic compounds in the industrial wastewater. Conclusively, these results suggest that ultrasonic irradiation may be extremely useful for the treatment of wastewater contaminated organic pollutants, which is difficult to treat economically by conventional treatment.

  • PDF

NOM fouling and Removal of Micro-pollutants in RO and NF Membrane processes (RO 및 NF막에서의 부식질에 의한 Fouling 및 미량오염물질의 제거)

  • Wang, Chang-Keun;Cha, Joon-Chul;Lee, Yong-Hyun;Kim, Su-Dong;Liu, Ju-Whan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.1
    • /
    • pp.73-80
    • /
    • 2004
  • This study investigated the phenomena of membrane fouling by NOM and the effect of the fouling on removal of micro-pollutants. NOM has a great effect on decline of permeate flux. Permeate flow rate was reduced by 88% in RO and 34.8% in NF for 323hr operation period. Removal rate of $UV_{254}$, is 87.4% in RO and 78.5% in NF and removal rate of DOC is 42.7% in RO and 32.9% in NF for 2mg/l humic acid. Removal efficiency of the micro-pollutants by the RO and NF membranes fouled by humic acid was mostly lower than that by the new membrane. The concentration polarization which affects the flux and the rejection was thought to occur in the active layer of the membrane, as the membrane was getting fouled.

A Review of Photocatalytic Treatment for Various Air Pollutants

  • Reddy, P. Venkata Laxma;Kim, Ki-Hyun;Kim, Yong-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.3
    • /
    • pp.181-188
    • /
    • 2011
  • Photocatalysis is a photochemical catalytic reaction which is a highly promising tool for the environmental cleanup process. It is very effective in treatment of environmental pollutants by its unique redox property. It has wide applications in the treatment of atmospheric pollutants (e.g., nitrogen dioxide, trichloroethylene, volatile organics, hydrogen sulfide, benzene, etc) through oxidative removal and by disinfection (aeromicro flora). In this research, the fundamental aspects of photocatalysis are described with respect to the composition of catalysts, experimental conditions (e.g., temperature, duration, etc), and interfering factors (e.g., catalyst deactivation).

Runoff of Pollutant Loads from Paddy Field Area in a Dry Year (갈수년 광역논에서의 오염부하의 유출 특성)

  • Oh, Seung-Young;Kim, Jin-Soo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.385-388
    • /
    • 2002
  • We investigated net outflow load and unit load of pollutants from a paddy fields area in dry year 2001. Amount of irrigation water in 2001 was about 61-63% of that in previous years 1999 and 2000 due to drought. The net outflow load and unit load of pollutants in 2001 were negative, showing that paddy fields acts as sink of pollutants due to function of water quality purification. The relationship between unit load of pollutants and net surface outflow (= surface outflow - irrigation water) showed positive correlation. The results showed that abatement of surface outflow by appropriate water management contribute to reduce surface outflow load from paddy fields.

  • PDF

Evaluation of Environmental Toxicities for Priority Water Pollutants in a Small Watershed by Bioassays - Comparision between Lettuce Seed Germination Test and Microtox Bioassay - (생물학적 검정법을 이용한 소규모 수계내 수질 오염물질의 환경독성 평가 -상추씨 발아시험과 Microtox 시험 비교-)

  • 이지나;황인영
    • Environmental Analysis Health and Toxicology
    • /
    • v.14 no.4
    • /
    • pp.135-144
    • /
    • 1999
  • Environmental toxicities of priority water pollutants were evaluated by two selected bioassays, Lettuce seed germination/elongation test and Microtox acute toxicity test. Toxic chemicals (heavy metals, polycyclic aromatic hydrocarbons, and phenolic compounds) inhibited the germination rate and root elongation of Lettuce seed, as well as the bioluminescence of Microtox bacteria. When test biota were exposed to target chemicals, the sensitivity of Lettuce bioassay was relatively lower than that of Microtox bioassay. However, Lettuce bioassay may be a good candidate for prescreening the environmental toxicities of priority water pollutants, since the testing method with Lettuce seed was relatively easier and more economic than with Microtox bacteria. Toxicity tests were conducted to compare the validity and sensitivity of both bioassays for sediment from a small stream passed through urban area as well as leachate from a municipal solid waste landfill. From experimental results, we found that Lettuce test and Microtox test are compensated each other as a battery of bioassay for evaluating the environmental toxicities of field samples obtained from a small stream contaminated by pollutants.

  • PDF

Research of Detection Method for Cytotoxic Effects of Environmental Pollutants Using Atomic Force Microscopy (AFM) in HeLa Cells (원자현미경(AFM)을 이용한 환경오염물질에 노출된 HeLa 세포의 표면변화 연구)

  • Lee, Si-Won;Lee, Soo-Il;Choi, Jin-Hee
    • Environmental Analysis Health and Toxicology
    • /
    • v.23 no.1
    • /
    • pp.47-51
    • /
    • 2008
  • The toxicity of environmental pollutants was measured between a image of the surface topography in HeLa cells using atomic force microscopy for the possibility of toxic effect measurement and environmental monitoring. A image of the surface topography by AFM were estimated as toxic endpoints. The surface topography by AFM was observed a change of the cell surface in the environmental pollutants, but the standard of the measurement requires for the dose-effect degree. The overall results indicate that the possibility of measurement using AFM were confirmed a dose-effect degree related toxic effects, but it requres correlation between more various biomarker and AFM's measurements if the possibility of the toxic effect measurement was established.

Cluster Analysis with Air Pollutants and Meteorological Factors in Seoul

  • Kim, Jae-Hee;Lim, Ji-Won
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.4
    • /
    • pp.773-787
    • /
    • 2003
  • Principal component analysis, factor analysis and cluster analysis have been performed to analyze the relationship between air pollutants and meteorological variables measured in 1999 in Seoul. In principal analysis, the first principal has been shown the contrast effect between $O_3$ and the other pollutants, the second principal has been shown the contrast effect between CO, $SO_2$, $NO_2$ and $O_3$, PM10, TSP. In factor analysis, the first factor has been found as PM10, TSP, $NO_2$ concentrations which are related with suspended particulates. As a result of cluster analysis, three clusters respectively have represented different air pollution levels, seasonal characteristics of air pollutants and meteorological situations.

  • PDF

Trends of Several Air Pollutants and the Effects of Ozone on the Plant Antioxidant system in Platanus occidentalis in Korea

  • Woo, Su-Young
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.2
    • /
    • pp.183-187
    • /
    • 2006
  • This study investigated concentrations of the several air pollutants and compared antioxidative enzyme activities on Platanus occidentalis because this tree species is one of the widespread street trees in Korea. This species has been emerging the ambient air pollutants during its growing periods. The purpose of this study was to identify the relationship between air pollution on the tree species and antioxidant enzyme activities on the trees. $O_3$, $NO_2$, CO and $SO_2$ concentrations of several cities in Korea were compared for last decades. Among the air pollutants, $O_3$ and $NO_2$ concentrations in six big cities in Korea showed similar increasing trends during this period. In contrast, $SO_2$ and CO concentrations in the same cities dramatically decreased between 1994 and 2005. Platanus occidentalis trees were controlled to investigate, ascorbate peroxidase (APX) and glutathione reductase (GR) activity. Ozone exposure generally increased APX and GR activities of tree seedlings. It is a typical compensatory strategy of stressed trees.