Clinical Usefulness of Point-of-care Test Chemistry Analyzer in Neonatal Intensive Care Unit

  • Jang, Yeong-Uk;Kim, Su-Nam;Cho, Hye-Jung;Sun, Yong-Han;Shim, So-Yeon;Son, Dong-Woo;Park, Pil-Whan
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.301-309
    • /
    • 2011
  • Purpose: Point-of-care tests (POCTs) have the potential to significantly influence management of neonates. The aim of this study was to assess the clinical usefulness of the POCT chemistry analyzer in a neonatal intensive care unit (NICU). Methods: Blood samples of neonates admitted to the NICU were tested using a POCT chemistry analyzer (Piccolo Xpress Chemistry Analyzer, Abaxis, Union City, CA, USA) and a central laboratory chemical analyzer (Chemistry analyzer 7600-110, Hitachi Ltd., Tokyo, Japan) from March to September, 2010. Correlation of 15 analytes between the POCT and the central laboratory machine was evaluated. For consistency of the POCT, three consecutive samplings were performed. Differences among the three tests were recorded. The causes of performance errors were checked through log files. Results: One hundred of 112 pairs of tests for accuracy performed in 54 neonates showed a high correlation between the two machines. Twelve performance errors occurred during the 112 tests. The most common error was insufficient sample error. Eighteen triplet tests performed in 18 patients for consistency revealed a difference range of 3-10%, which was considered to be acceptable. No error occurred during the 54 tests. Conclusion: The POCT is capable of analyzing multiple analytes with a minimal amount of whole blood in a short time. The few performance errors noted presently are likely preventable. This POCT is concluded to be suitable for use as a simple and rapid diagnostic method in the NICU with a minimal amount of blood collected in a less invasive manner.

Comparison of concurrent chemoradiotherapy versus sequential radiochemotherapy in patients with completely resected non-small cell lung cancer

  • Kim, Hwan-Ik;Noh, O Kyu;Oh, Young-Taek;Chun, Mison;Kim, Sang-Won;Cho, Oyeon;Heo, Jaesung
    • Radiation Oncology Journal
    • /
    • v.34 no.3
    • /
    • pp.202-208
    • /
    • 2016
  • Purpose: Our institution has implemented two different adjuvant protocols in treating patients with non-small cell lung cancer (NSCLC): chemotherapy followed by concurrent chemoradiotherapy (CT-CCRT) and sequential postoperative radiotherapy (PORT) followed by postoperative chemotherapy (POCT). We aimed to compare the clinical outcomes between the two adjuvant protocols. Materials and Methods: From March 1997 to October 2012, 68 patients were treated with CT-CCRT (n = 25) and sequential PORT followed by POCT (RT-CT; n = 43). The CT-CCRT protocol consisted of 2 cycles of cisplatin-based POCT followed by PORT concurrently with 2 cycles of POCT. The RT-CT protocol consisted of PORT followed by 4 cycles of cisplatin-based POCT. PORT was administered using conventional fractionation with a dose of 50.4-60 Gy. We compared the outcomes between the two adjuvant protocols and analyzed the clinical factors affecting survivals. Results: Median follow-up time was 43.9 months (range, 3.2 to 74.0 months), and the 5-year overall survival (OS), locoregional recurrence-free survival (LRFS), and distant metastasis-free survival (DMFS) were 53.9%, 68.2%, and 51.0%, respectively. There were no significant differences in OS (p = 0.074), LRFS (p = 0.094), and DMFS (p = 0.490) between the two protocols. In multivariable analyses, adjuvant protocol remained as a significant prognostic factor for LRFS, favouring CT-CCRT (hazard ratio [HR] = 3.506, p = 0.046) over RT-CT, not for OS (HR = 0.647, p = 0.229). Conclusion: CT-CCRT protocol increased LRFS more than RT-CT protocol in patients with completely resected NSCLC, but not in OS. Further studies are warranted to evaluate the benefit of CCRT strategy compared with sequential strategy.

Point-of-care Testing Device Interface in Hospital Information System Standard Connectivity - Using of case ASTM protocol of ABGA application POCT1-A2 - (현장형 임상검사장비와 병원정보시스템의 접속표준 - ASTM protocol을 사용하는 ABGA의 POCT1-A2적용사례 중심으로 -)

  • Kim, Seon-Chil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.33-37
    • /
    • 2008
  • To keep the online medical records available to anyone without constraint of time and space, introducing EMR (Electronic medical record), which is a clinical support management system. The purpose of this study is to develop interface standard of clinical test device. Integration and sharing of medical information is faced with enormous obstacles because medical organizations and associated companies are separately developing the interface. I hope that multi-function management system with workstation concept is operated to efficiently transmit clinical device result data based on this study. Transfer of precise medical result data available for decision making will improve quality of health care service.

  • PDF

The Principle and Trends of CRISPR/Cas Diagnosis (CRISPR/Cas 진단의 원리와 현황)

  • Park, Jeewoong;Kang, Bong Keun;Shin, Hwa Hui;Shin, Jun Geun
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.125-142
    • /
    • 2021
  • The POCT (point-of-care test) sensing that has been a fast-developing field is expected to be a next generation technology in health care. The POCT sensors for the detection of proteins, small molecules and especially nucleic acids have lately attracted considerable attention. According to the World Health Organization (WHO), the POCT methods are required to follow the ASSURED guidelines (Affordable, Sensitive, Specific, User- friendly, Robust and rapid, Equipment-free, Deliverable to all people who need the test). Recently, several CRISPR (Clustered Regularly Interspaced Short Palindromic Repeats) based diagnostic techniques using the sensitive gene recognition function of CRISPR have been reported. CRISPR/Cas (Cas, CRISPR associated protein) systems based detection technology is the most innovative gene analysis technology that is following the ASSURED guidelines. It is being re-emerged as a powerful diagnostic tool that can detect nucleic acids due to its characteristics that enable rapid, sensitive and specific analyses of nucleic acid. The first CRISPR-based diagnosis begins with the discovery of the additional function of Cas13a. The enzymatic cleavage occurs when the conjugate of Cas protein and CRISPR RNA (crRNA) detect a specific complementary sequence of the target sequence. Enzymatic cleavage occurs on not only the target sequence, but also all surrounding non-target single-stranded RNAs. This discovery was immediately utilized as a biosensor, and numerous sensor studies using CRISPR have been reported since then. In this review, the concept of CRISPR, the characteristics of the Cas protein required for CRISPR diagnosis, the current research trends of CRISPR diagnostic technology, and some aspects to be improved in the future are covered.

Disposable Strip-Type Biosensors for Amperometric Determination of Galactose

  • Gwon, Kihak;Lee, Seonhwa;Nam, Hakhyun;Shin, Jae Ho
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.310-317
    • /
    • 2020
  • A development of disposable strip-type galactose sensor for point-of-care testing (POCT) was studied, which was constructed using screen-printed carbon electrodes. Galactose levels were determined by the redox reaction of galactose oxidase in the presence of potassium ferricyanide as an electron transfer mediator in a small sample volume (i.e., less than 1 µL). The optimal performance of biosensor was systematically designated by varying applied potential, operating pH, mediator concentration, and amount of enzyme on the electrode. The sensor system was identified as a highly active for the galactose measurement in terms of the sensitivity (slope = 4.76 ± 0.05 nA/µM) with high sensor-to-sensor reproducibility, the linearity (R2 = 0.9915 in galactose concentration range from 0 to 400 µM), and response time (t95% = <17 s). A lower applied potential (i.e., 0.25 V vs. Ag/AgCl) allowed to minimize interference from readily oxidizable metabolites such as ascorbic acid, acetaminophen, uric acid, and acetoacetic acid. The proposed galactose sensor represents a promising system with advantage for use in POCT.

Study on the Latest Trends of u-Health and Relations of Medical Technologist

  • Sung, Hyun-Ho;An, Yong-Ho;Lee, Dong-Beom;Kim, Sang-Won;Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.4
    • /
    • pp.178-183
    • /
    • 2012
  • We investigated the latest trend of u-Health and relations with clinical technologist. Since 2000, Korea has become an aging society. Korea will become an aged society by 2018, and it is expected to enter the ultra-high aged society by 2026. Increase in over 65 years population means that the desire of medical service and care demand for the elderly is greatly required. In addition, many predicted Korean national health insurance would falter financially. Medical suppression policies and regulations are also amended continuously. U-Health based on the IT industry and development of related technologies and industries contains the variety concepts of telemedicine, telehealth, e-health, u-healthcare and POCT. Especially, the use of POCT supplied quick clinical examination is extending steadily in medical center and hospital, which will generate the field friction between nurses and medical technologists. In the transition situation from provider-centric service to consumer-driven health care system, this study recommended the principal role and correspondence of clinical laboratory workers and offered information about changes in healthcare market and the basic concept of expert system, measurement and the diagnosis principle to clinical technicians throughout the investigation of the recent research and government policy trends.

  • PDF

Facile and Effective Detection of Vitamin C on a Paper Based Kit (종이기반 소수성 채널에서의 효율적이고 간편한 비타민 C의 검출기술 개발)

  • Hwang, Jangsun;Seo, Youngmin;Choi, Jonghoon
    • KSBB Journal
    • /
    • v.31 no.1
    • /
    • pp.46-51
    • /
    • 2016
  • Recently paper based diagnostic kits have drawn great interest in the point-of-care testing market (POCT). The paper based detection systems provide inexpensive, rapid and safe analyses for disease markers and/or pathogens. Vitamin C (i.e., ascorbic acid) regulates body's immune system as an antioxidant agent. Humans, however, do not have enough amounts of enzymes involved in the synthesis of vitamin C that it is required to be obtained from their diets (e.g., beverages and/or supplements). Here, we have prepared a paper based kit to detect the concentration of Vitamin C presented in commercially available beverages. The evaluation provides the fast, simple and accurate results for detecting Vitamin C in the prepared paper based kit.

Ultra Fast Real-Time PCR for Detection of Babesia gibsoni as Point of Care Test

  • Yang, Yong-Sung;Mun, Myung-Jun;Yun, Young-Min
    • Journal of Veterinary Clinics
    • /
    • v.37 no.1
    • /
    • pp.23-27
    • /
    • 2020
  • Between May and November 2018, babesiosis was examined in 162 bloods samples obtained to an animal hospital in Jeju island for anemia and medical examination. Sixty-two of 162 (38.3%) were positive by PCR. The ultra fast real-time PCR test with blood directly analyzed without DNA extraction showed the same results. Accurate diagnosis, treatment and prognosis of babesiosis should be combined with clinical symptoms, blood tests, the babesia antibody test, and the PCR antigen test. Ultra fast real-time PCR, with these tests, is expected to be a point-of-care testing (POCT) for easy, fast and accurate diagnosis of babesiosis in the veterinary clinic.

Availability of Toxicologic Screening Tests in the Emergency Department (응급센터에서 시행하는 약물선별현장검사의 유용성)

  • Um, In-Kyung;Park, Jong-Su;Han, Kap-Su;Cho, Han-Jin;Choi, Sung-Hyuck;Lee, Sung-Woo;Hong, Yun-Sik
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.9 no.1
    • /
    • pp.26-29
    • /
    • 2011
  • Purpose: The role of a point of care test (POCT) is currently becoming important when treating patients and making decisions in the emergency department. It also plays a role for managing patients presenting with drug intoxication. But the availability of the test has not yet been studied in Korea. Therefore, we investigated the utility and the availability of POCT for drug screening used in the emergency department. Methods: This was a retrospective study for those patients with drug intoxication between January 2007 and December 2010 in an urban emergency department. Results: Between the study period, 543 patients were examined with a Triage$^{(R)}$-TOX Drug Screen. Among those, 248 (45.7%) patients showed negative results and 295 (54.3%) patients showed positive results. The sensitivity of the test for benzodiazepine, acetaminophen and tricyclic antidepressants were 85.9%, 100%, 79.2%, respectively. Conclusion: POCT of drug screening in emergency department showed good accuracy especially in patient with benzodiazepine, acetaminophen and tricyclic antidepressant intoxication. Therefore, it can be useful diagnostic tool for the management of intoxicated patients.

  • PDF