Analysis of Spatial Correlation and Linear Modeling of GNSS Error Components in South Korea (국내 GNSS 오차 성분별 공간 상관성 및 선형 모델링 특성 분석)

  • Sungik Kim;Yebin Lee;Yongrae Jo;Yunho Cha;Byungwoon Park;Sul Gee Park;Sang Hyun Park
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.13 no.3
    • /
    • pp.221-235
    • /
    • 2024
  • Errors included in Global Navigation Satellite System (GNSS) measurements degrade the performance of user position estimation but can be mitigated by spatial correlation properties. Augmentation systems providing correction data can be broadly categorized into State Space Representation (SSR) and Observation Space Representation (OSR) methods. The satellite-based cm-level augmentation service based on the SSR broadcasts correction data via satellite signals, unlike the traditional Real-Time Kinematic (RTK) and Network RTK methods, which use OSR. To provide a large amount of correction data via the limited bandwidth of the satellite communication, efficient message structure design considering service area, correction generation, and broadcast intervals is necessary. For systematic message design, it is necessary to analyze the influence of error components included in GNSS measurements. In this study, errors in satellite orbits, satellite clocks for GPS, Galileo, BeiDou, and QZSS satellite constellations ionospheric and tropospheric delays over one year were analyzed, and their spatial decorrelations and linear modeling characteristics were examined.

Effects of Artificial Saliva Contamination on the Bond Strength of Three Dentin Adhesives to Dentin of Primary Teeth (인공타액오염이 유치 상아질에서 3종 상아질 접착제의 결합 강도에 미치는 영향)

  • Bae, Youngeun;Kim, Shin;Jeong, Teasung;Kim, Jiyeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.72-81
    • /
    • 2017
  • The aim of this study was to evaluate the effectiveness of artificial saliva contamination and decontamination procedures at different stages of a bonding procedure on the microtensile bond strength (MTBS) of two one-step self-etch adhesives and a two-step total-etch adhesive to dentin of primary teeth. Forty-two extracted sound primary molars were randomly divided into three groups depending on three adhesives, Scotchbond Universal Adhesive (SBU), All-Bond Universal (ABU) and Prime & Bond NT (PNT). For each adhesive, the teeth were allocated into seven groups. Except for control group, group 1, the groups were contaminated with artificial saliva at three different stages: the groups 2 and 3 - before adhesive application; the groups 4 and 5 - before adhesive polymerization; the groups 6 and 7 - after adhesive polymerization. Decontaminating procedures were rinsing, air-drying (group 2, 4, 6) and air-drying (group 3, 5, 7). The specimens were restored with composite resin (Filtek, Z350) and microtensile bond strength was measured. The data was analyzed with one-way ANOVA and Tukey HSD test (p < 0.05). In the control group, using PNT resulted in significantly higher bond strength than when ABU and SBU were used (p < 0.001). For three adhesives, the groups 2, 4 and 6 had greater bond strength than the groups 3, 5 and 7. Also, when the artificial saliva was contaminated before adhesive polymerization (group 4, 5), it showed a significantly lower bond strength. Generally the two-step total-etch adhesive generated a higher bond strength than the one-step self-etch adhesive. Artificial saliva contamination before adhesive polymerization led to a drastic decrease in bond strength, and rinsing with water followed by air-drying could not recover the bond strength.

A Maritime DGPS Reference Station Configuration Proposal for Operation Improvement

  • Choi, Yong Kwon;Son, Seok Bo;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.4 no.4
    • /
    • pp.187-193
    • /
    • 2015
  • A maritime Differential Global Positioning System (DGPS) reference station broadcasts correction information to users having a DGPS receiver so that the navigation performance can be improved. A maritime DGPS reference station consists of a reference station (RS) that generates and broadcasts correction information, an integrity monitor (IM) that monitors the integrity of correction information, and a control station (CS) that controls them. A maritime DGPS reference station is continuously operated for 24 hours, and thus improvement in the ease of operation is a major element that can improve the performance of the system. In this study, a configuration of a maritime DGPS reference station that can improve the ease of operation and a relevant protocol were proposed, and an example of the implementation of the proposed system was presented.

Electrical steel and traction motor performance analysis for HEV/EV (HEV/EV 전기강판 및 구동모터 특성해석)

  • Kim, Ji-Yun;Kim, Gyo-Sung;Kim, Jae-Kwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.812-813
    • /
    • 2011
  • This paper presents the characteristic of newly developed electrical steel and motor performance analysis for HEV/EV. This material is developed and optimized for high frequency operation to reduce the core losses in traction motors to increase fuel efficiency. Four types of electrical steel are introduced, which are optimized for high flux density (PNHF), high frequency low core loss (PNF), high punchability (PNS) and high strength (PNT) to meet different specifications from different types of traction motors. To identify the motor performance with this material, finite element analysis was used to calculate core loss as well as Ld and Lq for efficiency map. Also structure analysis was performed to calculate stress on bridge rotor.

  • PDF

보완항법시스템 eLoran의 활용

  • Son, Pyo-Ung;Seo, Ji-Won
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.372-373
    • /
    • 2013
  • 위성항법시스템(GNSS)에 대한 전파교란에 대응하기 위한 보완항법시스템인 eLoran은 고출력의 지상파를 사용하기 때문에 전파교란이 현실적으로 힘들다는 장점이 있다. eLoran 신호는 세계표준시(UTC)에 동기화 되어있어서 송신 출력에 따라 실내와 같이 GNSS 신호의 수신이 힘든 경우에도 정확한 시각(timing) 정보를 제공할 수 있다. eLoran을 이용한 시각 정보 제공은 미국 국방부(DoD)에서도 최근에 많은 관심을 보이고 있다. 또한 eLoran은 자체 데이터 채널을 보유하고 있어서 eLoran 보정 신호를 전송할 수 있고, 전파기만에 대비하여 eLoran 신호인증 기법을 적용할 수 있다. 전파교란의 영향을 받지 않고 데이터를 전송할 수 있기 때문에 안정적인 데이터 전송이 필요한 각종 분야에서 eLoran 데이터 채널의 활용이 가능하다. 현재 우리나라는 GNSS를 보완하는 위치 항법 시각(PNT) 시스템으로써 2018년 정상 운용을 목표로 eLoran 시스템 구축 사업을 진행하고 있다.

  • PDF

Design of a Controller for the Semiconductor Fabricator with Improved Stability (반도체 전용기용 컨트롤러의 구조 안정화 설계)

  • Ro, Seung-Hoon;Shon, Jae-Yul;Lim, Yo-Han;Lee, Jae-Yul
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.12 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • The manufacturing process of the semiconductor is guided by the controller, which is supposed to sense the unexpected shocks and/or vibrations to shutdown the hard disk and the whole system in order to prevent the malfunction. This feature of controller would shutdown the system due to the instability of the controller itself as well as the instability of the manufacturing system. And consequently will cause significant losses. In this study the structure of a controller has been investigated to find ways to suppress the vibrations from the structure. The frequency response test and the computer simulation has been implemented to find the structure with improved stability. The result of the study shows that the relatively simple design alterations can eliminate most of the vibrations.

  • PDF

항로표지 분야 정보표준 검증을 위한 S-200 테스트베드 개발 연구

  • O, Se-Ung;Gang, Dong-U;Choe, Hyeon-Su
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.11a
    • /
    • pp.117-118
    • /
    • 2018
  • 국제항로표지협회(IALA)는 담당 분야(AtoN, AIS, VTS, PNT)의 정보교환 표준개발을 위해 국제수로기구에서 개발한 S-100(범용 수로데이터모델)을 적용하기로 결정하고, S-200 시리즈의 제품 사양서(Product specification)을 개발하고 있다. 개발 중인 S-200 시리즈 제품 사양서로는 S-201 항로표지, S-210 IVEF, S-230 ASM, S-240 DGNSS 기준국 목록 등이 있으며 일부 표준은 개발 완성 단계에 있다. S-200 제품 사양서는 정보 교환을 위한 내용, 구조, 포맷, 심볼 등의 기술사항이 포함되어 있으므로 표준을 검증하거나 현업으로 적용방안을 검토하기 위해서는 테스트 베드를 통한 검증이 요구된다. 본 연구에서는 항로표지 분야 정보교환 표준인 S-200 시리즈 제품 사양서가 개발되고 있는 것과 관련하여 S-200 테스트 베드 설계 및 시범 개발 결과를 소개 한다.

  • PDF

Alternative PNT Requirements and Technology Analysis (GNSS 대안항법시스템 요구사항 및 기술 분석)

  • Jo, Sanghoon;Kang, Seung-Eun;Kang, Ja-Young;Ko, Sangho
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.20 no.3
    • /
    • pp.28-34
    • /
    • 2012
  • The recent transition to Performance Based Navigation in aviation enhances the accuracy of aircraft position, safety and efficiency in air traffic operations by using satellite-based navigation system such as GNSS. However, intentional interferences with GNSS signal as well as ones coming from natural phenomena such as solar storm increase. GNSS have very low power and therefore their signals are more susceptible to interferences than ground-based navigation signals. This paper introduces requirements of alternative positioning, navigation and timing(APNT) system and relevant technologies when the GNSS signals are not valid.

Development of MF R-Mode Transmitting System for Maritime Resilient PNT in the Republic of Korea

  • Han, Younghoon;Son, Pyo-Woong;Seo, Kiyeol;Fang, Tae Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.4
    • /
    • pp.239-244
    • /
    • 2022
  • R-Mode is terrestrial based Global Navigation Satellite System (GNSS) backup radio navigation technology which used existing maritime information service infrastructure. It has advantages on reduce the cost and reutilize the frequency resource. In this paper, we propose a method to develop a medium-frequency (MF) band R-Mode transmitting station by utilizing the currently operating Differential GNSS (DGNSS) reference station infrastructure. To this end, the considerations for co-operating the DGNSS reference station and the MF R-Mode transmitting station are analyzed. In this process, we also analyze what is necessary to configure the communication system as a navigation system for range measurement. Based on the analysis result, MF R-Mode transmitting station system is designed and architecture is proposed. The developed system is installed in the field, and the performance evaluation results is presented.