• Title/Summary/Keyword: PMSM drive

Search Result 193, Processing Time 0.034 seconds

Correction on Current Measurement Errors for Accurate Flux Estimation of AC Drives at Low Stator Frequency (저속영역에서 교류전동기의 정확한 자속추정을 위한 전류측정오차 보상)

  • Cho, Kyung-Rae;Seok, Jul-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.65-73
    • /
    • 2007
  • This paper presents an on-line correction method of current measurement errors for a pure-integration-based flux estimation down to 1-Hz stator frequency. An observer-based approach is taken as one possible solution of eliminating the dc offset and the negative sequence component of unbalanced gains in the synchronous coordinate. At the same time, the positive sequence component estimation is performed by creating an error signal between a motor model reference and an estimated q-axis rotor flux established by a permanent magnet (PM) in the synchronous coordinate. The compensator utilizes a PI controller that controls the error signal to zero. The proposed technique further contains a residual error compensator to completely eliminate miscellaneous disturbances in the estimated flux. The developed algorithm has been implemented on a 1.1-kW permanent magnet synchronous motor (PMSM) drive to confirm the effectiveness of the proposed scheme.

Speed Controller Transition Method for I-F Operation and Sensorless Operation of Permanent Magnet Synchronous Motor (영구자석 동기 전동기의 I-F 구동과 센서리스 구동을 위한 속도 제어 절환 기법)

  • Kim, Dong-Uk;Kim, Sungmin
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.543-551
    • /
    • 2019
  • Permanent Magnet Synchronous Motors(PMSMs) have a wider range of applications due to their high output density and high efficiency. PMSMs are used not only in high-power density, high-performance motor-driven systems such as vehicle and robots, but also in systems where cost-cutting is very important, such as washing machines, air conditioners and refrigerators. To reduce costs, position sensorless control is required, which is generally difficult to be used under conditions of starting the motor. Thus, the I-F speed control that rotates the current vector at any speed in the starting procedure should be used at first, and then the sensorless speed control could be applied after PMSM rotates above a certain speed. Speed control performance in I-F speed control and sensorless speed control is very important. And more speed control performance should be maintained even in the transient in which the two control techniques are changed. In this paper, the speed controller transition method from I-F speed control to sensorless speed control of permanent magnet synchronous motor is proposed. Experiments were carried out on the washing machine drive system to verify the performance of the proposed technique.

A Study on Robust and Precise Position Control of PMSM under Disturbance Variation (외란의 변화가 있는 PMSM의 강인하고 정밀한 위치 제어에 대한 연구)

  • Lee, Ik-Sun;Yeo, Won-Seok;Jung, Sung-Chul;Park, Keon-Ho;Ko, Jong-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1423-1433
    • /
    • 2018
  • Recently, a permanent magnet synchronous motor of middle and small-capacity has high torque, high precision control and acceleration / deceleration characteristics. But existing control has several problems that include unpredictable disturbances and parameter changes in the high accuracy and rigidity control industry or nonlinear dynamic characteristics not considered in the driving part. In addition, in the drive method for the control of low-vibration and high-precision, the process of connecting the permanent magnet synchronous motor and the load may cause the response characteristic of the system to become very unstable, to cause vibration, and to overload the system. In order to solve these problems, various studies such as adaptive control, optimal control, robust control and artificial neural network have been actively conducted. In this paper, an incremental encoder of the permanent magnet synchronous motor is used to detect the position of the rotor. And the position of the detected rotor is used for low vibration and high precision position control. As the controller, we propose augmented state feedback control with a speed observer and first order deadbeat disturbance observer. The augmented state feedback controller performs control that the position of the rotor reaches the reference position quickly and precisely. The addition of the speed observer to this augmented state feedback controller compensates for the drop in speed response characteristics by using the previously calculated speed value for the control. The first order deadbeat disturbance observer performs control to reduce the vibration of the motor by compensating for the vibrating component or disturbance that the mechanism has. Since the deadbeat disturbance observer has a characteristic of being vulnerable to noise, it is supplemented by moving average filter method to reduce the influence of the noise. Thus, the new controller with the first order deadbeat disturbance observer can perform more robustness and precise the position control for the influence of large inertial load and natural frequency. The simulation stability and efficiency has been obtained through C language and Matlab Simulink. In addition, the experiment of actual 2.5[kW] permanent magnet synchronous motor was verified.

Dead Time Compensation and Polarity Check of Phase Currents Based on Programmable Low-pass Filter for Automotive Electric Drive Systems (자동차 전동 시스템을 위한 Programmable 저역 통과 필터 기반의 상전류 극성 판단 및 데드타임 보상)

  • Choi, Chinchul;Lee, Kangseok;Lee, Wootaik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.6
    • /
    • pp.23-30
    • /
    • 2014
  • This paper proposes a dead time compensation method for an AC motor drive using phase current polarity information which is detected based on a digital programmable low-pass filter (PLPF). The polarity detection using the PLPF is an alternative solution of a conventional method which uses a general low-pass filter (LPF) and hysteresis bands in order to avoid jittering due to noises. The PLPF not only adjusts its cutoff frequency according to the synchronous frequency of AC motors but also eliminates a gain attenuation and phase delay which are main problems of the general LPF. Through the PLPF, a fundamental component signal without gain and phase distortions is extracted from the measured raw current signal with noise. By use of the fundamental component, the polarity of current is effectively detected by reducing the hysteresis band. Finally, the proposed method compensates the dead time effects by adding or subtracting average voltage value to voltage references of the controller according to the detected current polarity information. The proposed compensation method is experimentally verified by compared with the conventional method.

Field Weakening Operation of a High Torque Density Five Phase Permanent Magnet Motor Drive (고밀도 토크를 가지는 5상 영구자석형 전동기의 약계자 제어)

  • Kim, Nam-Hun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.318-323
    • /
    • 2007
  • This paper investigates the field weakening operation of a five-phase permanent magnet motor. The proposed motor has concentrated windings such that the produced back-EMF is almost trapezoidal and is supplied with the combined sinusoidal plus third harmonic of currents to produce trapezoidal current. Therefore this motor, while generating the same average torque as an equivalent permanent magnet brushless dc motor, overcomes its disadvantages. It is shown that torque producing and flux producing components of current for this motor can be decoupled by using multiple reference frame transformation. Therefore, Vector control is easily applicable to the motor. This motor has benefits such as high torque density of a BLDC motor below the rated speed and controllability of PMSM above the rated speed and during the field weakening region and simulation and experimental results are provided to prove the validity of the superior performance of this drive.

On-Line Feed-Forward Dead-Time Compensation Method (온라인 전향 데드타임 보상기법)

  • 김현수;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.267-274
    • /
    • 2004
  • In this paper, a new on-line dead-time compensation method is proposed. The output voltage errors due to the dead-time effect is considered as disturbance voltages. The magnitude of the disturbance voltages is estimated using a time delay control technique and the disturbance voltages are calculated using the estimated values, measured currents, and position information. The calculated disturbance voltages are fed to voltage references in order to compensate the dead-time effect. The proposed method is applied to a PM synchronous motor drive system and implemented in a digital manner using a digital signal processor (DSP) TMS320C31. The experiments are carried out for this system to show the effectiveness of the proposed method and the results show the validity of the proposed method.

A Fuzzy Logical Optimal Efficiency Control of Permanent Magnet Synchronous Motor (PMSM의 퍼지 로직 최적 효율 제어)

  • Zhou, Guang-Xu;Lee, Dong-Hee;Ahm, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.97-99
    • /
    • 2007
  • This paper presents a fuzzy logical control method to implement an on-line optimum efficiency control for Permanent Magnet Synchronous Motor. This method real-timely adjusts the output voltage of the inverter system to achieve the optimum running efficiency of the whole system. At first, the input power is calculated during the steady state in the process of efficiency optimizing. To exactly estimate the steady state of the system, this section needs check up the speed setting on timely. The second section is to calculate input power of dc-bus. The exact measurement of the voltage and current is the vital point to acquire the input power. The third section is the fuzzy logic control unit, which is the key of the whole drive system. Based on the change of input power of dc-bus and output voltage, the variable of output voltage is gained by the fuzzy logical unit. With the on-line optimizing. the whole system call fulfill the minimum input power of dc-bus on the running state. The experimental result proves that the system applied the adjustable V/f control method and the efficiency-optimizing unit possesses optimum efficiency, and it is a better choice for simple variable speed applications such as fans and pump.

  • PDF

Sensorless Scheme for Interior Permanent Magnet Synchronous Motors with a Wide Speed Control Range

  • Hong, Chan-Hee;Lee, Ju;Lee, Dong-Myung
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2173-2181
    • /
    • 2016
  • Permanent magnet synchronous motors (PMSMs) have higher torque and superior output power per volume than other types of AC motors. They are commonly used for applications that require a large output power and a wide range of speed. For precise control of PMSMs, knowing the accurate position of the rotor is essential, and normally position sensors such as a resolver or an encoder are employed. On the other hand, the position sensors make the driving system expensive and unstable if the attached sensor malfunctions. Therefore, sensorless algorithms are widely researched nowadays, to reduce the cost and cope with sensor failure. This paper proposes a sensorless algorithm that can be applied to a wide range of speed. The proposed method features a robust operation at low-speed as well as high-speed ranges by employing a gain adjustment scheme and intermittent voltage pulse injection method. In the proposed scheme the position estimation gain is tuned by a closed loop manner to have stable operation in tough driving environment. The proposed algorithm is fully verified by various experiments done with a 1 kW outer rotor-type PMSM.

Controller Scheduling and Performance Analysis for Multi-Motor Control (다중 모터 제어를 위한 제어기 스케쥴링 및 성능 분석)

  • Kwon, Jae-Min;Lee, Kyung-Jung;Ahn, Hyun-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.71-77
    • /
    • 2015
  • In this paper, we propose a scheduling method for signal measurement and control algorithm execution in a multi-motor drive controller. The multi-motor controller which is used for vehicle control receives position/velocity command and performs position/velocity control and current control. Internal resource allocation and control algorithm execution timing are very important when one microcontroller is used for multi-motor drives. The control performance of the velocity control system is verified by varying ADC(Analog to Digital Converter) conversion timing and algorithm execution timing using real experiments.

Transient Performance of a Hybrid Electric Vehicle with Multiple Input DC-DC Converter

  • Nashed, Maged N.F.
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.230-238
    • /
    • 2003
  • Electric vehicles (EV) demands for greater acceleration, performance and vehicle range in pure electric vehicles plus mandated requirements to further reduce emissions in hybrid electric vehicles (HEV) increase the appeal for combined on-board energy storage systems and generators. And the power electronics plays an important role in providing an interface between fuel cells (FC) and loads. This paper deals with a multiple input DC-DC power converter devoted to combine the power flowing of multi-source on energy systems. The multi-source is composed of (i) FC system as a prime power demands, (ii) super capacitor banks as energy storage devices for high and intense power demands, (iii) superconducting magnetic energy storage system (SMES), (iv) multiple input DC-DC power converter and (v) a three phase inverter-fed permanent magnet synchronous motor as a drive. In this system, It is used super capacitor banks and superconducting magnetic energy replaces from the battery system. The modeling and transient performance simulation is effective for reducing transient influence caused by sudden charge of effective load. The main purpose of power electronic converters is to convert the DC power output from the fuel cell and other to a suitable AC voltage, which can be connected to electric loads directly (PMSM). The fuel cell and other output is connected to the DC-DC converter, which regulates the DC link voltage.