• Title/Summary/Keyword: PM machine

Search Result 511, Processing Time 0.033 seconds

A Novel Picometer Positioning System for Machine Tools and Measuring Machines

  • Mizumoto, Hiroshi;Yabuta, Yoshito;Arii, Shiroh;Tazoe, Yoichi;Kami, Yoshihiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.123-128
    • /
    • 2005
  • A novel tri-mode ultraprecision positioning system for machine tools and measuring machine is proposed. The basic coarse mode uses a Twist-roller Friction Drive (abbr. TFD), and controls several tens of millimeters of the machine-table travel with nanometer order of positioning resolution. The fine mode also utilizes the TFD with a fine adjusting mechanism. The resolution of the fine mode is in the range of sub-nanometer. For realizing picometer positioning, the ultra-fine mode is executed by using an active aerostatic guideway. On the bearing surface of this active guideway, several Active Inherent Restrictors (abbr. AIRs) are embedded for controlling the table position. An AIR unit consists of a piezoelectric actuator having a through hole, one end of the hole on the bearing surface acts as an inherent restrictor. Owing to the aerostatic mechanism of the AIR, the deformation of the piezoelectric actuator in the AIR unit causes much reduced table displacement. Such motion reduction is effective for ultraprecision positioning. Current positioning resolution of the ultra-fine mode is 50pm, however the final goal of the positioning resolution is expected to be in the order of picometer.

  • PDF

Modeling and Measurement of Thermal Errors for Machining Center using On-Machine Measurement System (기상계측 시스템을 이용한 머시닝센터의 열변형 오차 모델링 및 오차측정)

  • 이재종;양민양
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.1
    • /
    • pp.120-128
    • /
    • 2000
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric errors, thermally-induced errors, and the deterioration of the machine tools. Geometric and thermal errors of machine tools should be measured and compensated to manufacture high quality products. In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses and a designed spherical ball artifact (SBA). Experiments, performed with the developed measurement system, show that the system provides a high measuring accuracy, with repeatability of $\pm$2${\mu}{\textrm}{m}$ in X, Y and Z directions. It is believed that the developed measurement system can be also applied to the machine tools with CNC controller. In addition, machining accuracy and product quality can be improved by using the developed measurement system when the spherical ball artifact is mounted on the modular fixture.

  • PDF

Preliminary Design Analysis of Low Speed Interior Permanent Magnet Machine with Distributed and Concentrated Windings

  • Ahsanullah, Kazi;Dutta, Rukmi;Rahman, M.F.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.139-147
    • /
    • 2014
  • The paper presents a systematic comparison of four topologies of the interior permanent magnet machine (IPMM) designed for low speed applications. This comparative study investigates the suitability of the concentrated winding and distributed winding in the stator and the flat-shaped or V-shaped magnets in the rotor poles. The paper also studies the inductance characteristics of the designs using finite element analysis. Various steps taken to minimize the cogging torque and torque ripple in the studied machines were also discussed in details.

Development of Laser Diode Tester and Position Compensation using Feedback with Machine Vision (Laser Diode Tester 개발과 비젼 피드백을 이용한 위치 보정)

  • 김재희;유철우;박상민;유범상
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.30-36
    • /
    • 2004
  • The development of LD(Laser Diode) tester and its control system based on the graphical programming language(LabVIEW) is addressed. The ill tester is used to check the optic power and the optic spectrum of the LD Chip. The emitter size of LD chip and the diameter of the Detector(optic fiber and photo diode) are very small, therefore the test device needs high accuracy. But each motion part of the test device could not accomplish high accuracy due to the limit of the mechanical performance. So, an image processing with machine vision is proposed to compensate for the error. By adopting our method we can reduce the error of position within $\pm$5$\mu\textrm{m}$.

Development of Automatic Welding Machine and Weld-Quality Improvement for Automobile Parts (자동차부품 용접자동화장치 개발 및 용접품질 개선에 관한 연구)

  • Kim, Kyo-Hyoung;Lee, Ki-Sul;Lee, Taik-Soon;Joo, Hae-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.7 no.1
    • /
    • pp.63-73
    • /
    • 1990
  • Low cost automatic welding machine is developed for the purpose of welding process automation of automobile parts with two dimensional welding joints. Developed gantry type machine is equipped with X, Y and roll axis stepping motors, and dirive units units are designed by two phase on drive scheme using shift registers. Control system is constructed by single board microcomputer of Z80A CPU, and also it is equipped with parallel input output ports and counter-timer chips. Linear and circular interpolation of welding head movement is accomplished by employing software digital differential analyzers. It has been shown that contour error of develped system is withi ${\pm}1.0mm$, meaning that the machine is suitable for CO2 arc welding process of automoble parts and is expected it's application to industry.

  • PDF

A Study on the Design of Linear Motor with Transverse Flux Configuration for Railway Traction System (철도 차량용 고출력 횡축형 전동기 설계에 관한 연구)

  • Gang, Do-Hyeon;Weh, Herbert
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.6
    • /
    • pp.301-308
    • /
    • 1999
  • According to the development of power electronic element(GTO, IGBT) and material for electrical machines(permanent magnet, super conductor), the technology for electrical machines is now a day rapidly developing. Here with, a novel electrical machine, based on the new conception of transverse flux configuration leads to a considerable increase in power density and enables simultaneously high efficiency. The designed and measured performance of transverse machine for railway traction system revealed a great potential of system improvements to reduce linear motor mass.

  • PDF

Design Techniques for Reducing Cogging Torque in Permanent Magnet Flux Switching Machine

  • Wang, Daohan;Wang, Xiuhe;Jung, Sang-Yong
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.361-364
    • /
    • 2013
  • Permanent magnet flux switching motor (PMFSM) is a novel double salient machine which employs PMs instead of field winding for excitation. PMFSM contains only one set of armature winding, thereby features simple control strategy, low cost power inverter and substantial high efficiency. Due to the unique double salient structure and operation principle, the generated cogging torque in PMFSM is critical and quite different compared to the traditional PM machines. This paper presents and investigates various design techniques for reducing cogging torque in PMFSM. Firstly, an analytical model is proposed to study the influence of different methods on cogging torque. Then the optimal design parameters for minimizing cogging torque are determined by the analytical model, which significantly reduces the computational efforts. At last, the cogging torque with different design approaches are simulated by FEA along with the average output electromagnetic torque, which validates the analysis above.

A Representative Pattern Generation Algorithm Based on Evaluation And Selection (평가와 선택기법에 기반한 대표패턴 생성 알고리즘)

  • Yih, Hyeong-Il
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.3
    • /
    • pp.139-147
    • /
    • 2009
  • The memory based reasoning just stores in the memory in the form of the training pattern of the representative pattern. And it classifies through the distance calculation with the test pattern. Because it uses the techniques which stores the training pattern whole in the memory or in which it replaces training patterns with the representative pattern. Due to this, the memory in which it is a lot for the other machine learning techniques is required. And as the moreover stored training pattern increases, the time required for a classification is very much required. In this paper, We propose the EAS(Evaluation And Selection) algorithm in order to minimize memory usage and to improve classification performance. After partitioning the training space, this evaluates each partitioned space as MDL and PM method. The partitioned space in which the evaluation result is most excellent makes into the representative pattern. Remainder partitioned spaces again partitions and repeat the evaluation. We verify the performance of Proposed algorithm using benchmark data sets from UCI Machine Learning Repository.

A Clinical Study of Changes in Serum Electrolyte Concentration During and After Extracorporeal Circulation with Heart-Lung Machine (심폐기 체외순환에 의한 혈청 전해질 변동에 관한 연구)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.11 no.4
    • /
    • pp.404-415
    • /
    • 1978
  • The present study was carried out to develop the better measures for safety of open heart surgery under extracorporeal circulation (ECC) with Heart-Lung-Machine by preventing changes in the concentrations of serum electrolytes during and after ECC. For this purpose, the cocentrations of serum electrolytes were measured before, during, and after ECC in 21 patients with congenital and acquired heart diseases who received open heart surger, - under ECC using Heart-Lung-Machine. Also considered was the development of safety measured by which changes in serum electrolyte concentrations were prevented during and after open heart surgery under ECC. The mean values for serum sodium levels were observed to be ; $13.14{\pm}0.47$mEq./L. for the samples obtained before ECC. $139.59{\pm}0.68$mEq./L. for the samples obtained 10 minutes after ECC and $138.0{\pm}0.68$mEq./L. for the samples obt"ined 24 hours after ECC. These results indicate that serum sodium concentrations were \\'ithin normal range during and until 24 hours after ECC. 2) The concentrations of serum chloride were found to be $105.38{\pm}0.70$105.38$\pm$0. 70 mEq./L. for the samples collected before ECC, $105.07{\pm}1.01$mEq./L. for the Simples collected 24 minutes aiter ECC and $101.95{\pm}1.09$mEq./L. for the samples collectect 24 hours afte ECC. As was tile case with serum sodium levels, no significant changes were observed in serum chloride levels during and 24 hours after ECC. 3)With proper provisions of potassium chloride solution during ECC, the concentrations of serum potassium were found to be $4.22{\pm}0.06$mEq./L. for the samples removed before EeC, $4.06{\pm}0.14$mEq./L. for the samples removed 10 minutes after ECC and $4.39{\pm}0.07$ mEq./L. for the samples removed 24 hours after ECC. 4)The concentrations of serum calcium were also maintained within normal during and after ECC; $9.15{\pm}0.14$mg/dl for the serum collected before ECC, $8.36{\pm}0.21$mg/dI for the serum collected 10 minutes after ECC and $8.47{\pm}0.14$mg/dl 21 hours after ECC. The maintenance of serum calcium level within normal throughout ECC was achieved by parenteral administrations of calcium gluconate as frequent as required. 5) As were the cases with serum potassium and calcium, the concentrations of plasma bicarbonate was regulated within normal range during and after ECC, only when sodium bicarbonate solution was admini"tered parenterally as it was required; $23.7{\pm}0.50$mEq./L. for the serum collected before ECC. $22.33{\pm}1.09$mEq.lL. for the serum collected 10 minutes after ECC and $25.3{\pm}0.96$mEq./L. for the serum collected 24 hours after ECC. The above results indicate tha t during and after ECC serum sodium and chloride levels remined unchanged without any provision of normal saline, while serum potassium, calcium, and bicarbonate concentrations were kept within normal limits only when these ealectrolytes were administered through parenteral routes. With these results it can be concluded that serum potassium, calcium, and bicarbonate levels should be determined as often as possible during and after ECC and that in order to maintain serum electrolyte levels within normal these electrolytes in the forms of potassium chloride, calcium gluconate, and sodium bicarbonate shou'd be given parenterally as they were found to be required.

  • PDF

Development and Animal Tests of Prototype Oxygen Concentrator (국산 산소 농축기의 개발 및 동물실험)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • v.31 no.7
    • /
    • pp.643-649
    • /
    • 1998
  • Background: For the patient with chronic obstructive pulmonary disease requiring long-term oxygen therapy, oxygen concentrator machines are already widely available for use in home. In this study, we used mongrel dogs as test subjects to compare the functional efficiency and safety of the oxygen concentrator developed by our own research team with those of the imported FORLIFE(TM) machine made by AIRSEP Corp. Method and method: To test mechanical reliability, the concentrations of oxygen delivered were measured after 4 hours of continuous operation. Sixteen mongrel dogs were divided into two equal groups. Mongrel dogs in group A were given oxygen using the imported oxygen concentrator, and those in group B using the machine developed. 5 l/min of oxygen were given, after which vital signs were analyzed, arterial blood gases measured, and blood chemistry tests carried out. Results: After 4 hours of continuous operation, the imported model performed better, giving 98${\pm}$3% oxygen, compared to our model, which gave 91${\pm}$1%. In the animal experiments, oxygen concentrations were measured at the inlet of face mask 1, 2, 3, and 4 hours after continuous administration, and there was no statistically significant difference(repeated measures of analysis of variance p=0.70) between the values of 70.6${\pm}$2.5%, 67.1${\pm}$2.9%, 68.2${\pm}$2.6%, and 64.9${\pm}$3.9% that were measured from group A, and the values of 65.1${\pm}$4.8%, 65.2${\pm}$3.6%, 68.7${\pm}$4.3%, and 66.0${\pm}$5.0% measured from group B. Before oxygen administration, and at 1, 2, 3, and 4 hours after oxygen administration, arterial blood partial pressure of oxygen 87.2${\pm}$2.5 mmHg, 347.4${\pm}$29.3 mmHg, 353.4${\pm}$21.2 mmHg, 343.0${\pm}$28.8 mmHg, and 321.6${\pm}$24.4 mmHg, respectively, were read from group A, which were not statistically different (p=0.24) to the values of 102.5${\pm}$9.6 mmHg, 300.3${\pm}$17.1 mmHg, 321.6${\pm}$23.7 mmHg, 303.4${\pm}$27.4 mmHg, and 273.5${\pm}$25.9 mmHg read from group B. Nonetheless, the arterial blood partial pressure of oxygen values appear to be somewhat higher in dogs that were given oxygen using the imported oxygen concentrator. Conclusions: From these results the prototype oxygen concentrator developed appears to function relatively satisfactorily compared to the imported, established model, but may be criticized for the excessive noise generated and poor long-term endurance or consistency, which need improvement.

  • PDF