• Title/Summary/Keyword: PM machine

Search Result 511, Processing Time 0.03 seconds

Effects of same TDF Factors on Body Weight of Mice and Peripheral Blood Picture (상이한 분할조사가 마우스의 체중과 말초혈액에 미치는 효과)

  • Shin, Sei-One;Kim, Sung-Kyu;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.4 no.2
    • /
    • pp.89-96
    • /
    • 1987
  • Using same TDE factors, the authors studied the effects of whole abdominal irradiation on body weight and peripheral blood picture in $30{\pm}3$ day old mice. Fractions of 100 and 200 cGy were given five times a week to the final TDF factors l7, 33, and 49. Total 80 mice were irradiated with orthovoltage x-ray machine. Our results can be summarized as follows : There were no significant differences by sex. Body weight was progressively decreased by the duration for irradiation, but no remarkable difference by fractional dose. Hemoglobin level showed no remarkble change by fractional dose or TDF factors. Leukopenic changes showed that severity of decrease seems to be more related to TDF factors. There were no significant changes of differential count by TDF factors of total doses.

  • PDF

Optimal Design of Interior PM Synchronous Machines Using Randomly-Guided Mesh Adaptive Direct Search Algorithms (RG-MADS를 적용한 매입형 영구자석 동기전동기의 최적설계)

  • Kim, Kwang-Duck;Lee, Dong-Su;Jung, Sang-Yong;Kim, Jong-Wook;Lee, Cheol-Gyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.216-222
    • /
    • 2012
  • Newly proposed RG-MADS (Randomly Guided Mesh Adaptive Direct Search) has been applied to the optimal design of Interior Permanent Magnet Synchronous Motor (IPMSM) which has the distinctive features of magnetic saturation. RG-MADS, advanced from classical MADS algorithm, has the superiority in computational time and reliable convergence accuracy to the optimal solution, thus it is appropriate to the optimal design of IPMSM coupled with time-consuming Finite Element Analysis (FEA), necessary to the nonlinear magnetic application for better accuracy. Effectiveness of RG-MADS has been verified through the well-known benchmark-functions beforehand. In addition, the proposed RG-MADS has been applied to the optimal design of IPMSM aiming at maximizing the Maximum Torque Per Ampere (MTPA), which is regarded as representative design goal of IPMSM.

Torque Trajectory Control of Interior PM Synchronous Motor Using Adaptive Input-Output Linearization Technique (적응 입출력 선형화 제어 기법을 이용한 매입형 영구 자석 동기 전동기의 토오크 궤적 제어)

  • Kim, Kyeong-Hwa;Baik, In-Cheol;Kim, Hyun-Soo;Moon, Gun-Woo;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.578-581
    • /
    • 1996
  • A torque trajectory control of the IPM synchronous motor using an adaptive input-output linearization technique is proposed. The input-output linearization is performed using the estimated torque output with the knowledge of machine parameters. The linearized model gives the output torque error under the variation of the flux linkage. To give a good torque tracking in the presence of the flux linkage variation, the flux linkage will be estimated where the adaptation law h derived by the Popov's hyperstability theory and the positivity concept. This estimated value is also used for the generation of the d-axis current command for the maximum torque control. Thus, a good torque tracking and the exact maximum torque-per-current operation will be obtained.

  • PDF

Visibility of the mandibular canal and the mental foramen in panoramic radiography (파노라마 방사선사진에서 하악관과 이공의 관찰되는 정도)

  • Jeong Seon-Jin;Choi Eui-Hwan;Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.31 no.3
    • /
    • pp.153-158
    • /
    • 2001
  • Purpose : To determine the head position that the superior border of the mandibular canal as well as mental foramen can be more clearly visualized in panoramic radiography Materials and Methods : Ten dry mandibles were radiographed bilaterally using PM 2002 CC panoramic machine. A 20 mm thick aluminium filter was added to the slit collimator to obtain radiographs with acceptable density. The specimens were tilted by 2, 4, 6, 8, and 10 degrees downward with and without radiopaque markers. Radiopaque markers were inserted into the mandibular canals and the mental canals of each side of the specimens to serve as reference image when assessing the radiographs. The visibility of the mandibular canal and the mental foramen was estimated by 4 observers on all radiographs. The obtained results were analyzed statistically. Results: Mandibular canals were significantly more clearly visible in the radiographs with 4 and 6 degree downward position on both sides (P<0.05). Mental foramens were significantly more clearly visible in the radiographs with 4, 6, and 8 degree downward on right side and 6 degree downward on left side (P<0.05). There was not significant difference between right and left sides. Conclusion: Panoramic radiographs with 4 to 6 degree downward tilting could be valuable in locating the mandibular canal as well as the mental foramen.

  • PDF

An Anti-Overload Model for OpenStack Based on an Effective Dynamic Migration

  • Ammar, Al-moalmi;Luo, Juan;Tang, Zhuo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.9
    • /
    • pp.4165-4187
    • /
    • 2016
  • As an emerging technology, cloud computing is a revolution in information technology that attracts significant attention from both public and private sectors. In this paper, we proposed a dynamic approach for live migration to obviate overloaded machines. This approach is applied on OpenStack, which rapidly grows in an open source cloud computing platform. We conducted a cost-aware dynamic live migration for virtual machines (VMs) at an appropriate time to obviate the violation of service level agreement (SLA) before it happens. We conducted a preemptive migration to offload physical machine (PM) before the overload situation depending on the predictive method. We have carried out a distributed model, a predictive method, and a dynamic threshold policy, which are efficient for the scalable environment as cloud computing. Experimental results have indicated that our model succeeded in avoiding the overload at a suitable time. The simulation results from our solution remarked the very efficient reduction of VM migrations and SLA violation, which could help cloud providers to deliver a good quality of service (QoS).

The Analysis of Garlic Quality Based on Physical and Morphological Properties of a Whole Bulb of Garlic at the Harvesting Season - Discrimination Algorithms for Garlic Quality Grading - (수확기 통마늘의 물리적 및 형상적 특성에 기초한 마늘 품질 분석 - 마늘 등급판정을 위한 판별 알고리즘 -)

  • 박준걸;장영창;노광모;이충호
    • Journal of Biosystems Engineering
    • /
    • v.24 no.3
    • /
    • pp.225-234
    • /
    • 1999
  • This study was performed as a basic research for establishing an objective quality evaluation method on whole bulbs of garlic. The size of a whole bulb of garlic, the number and the uniformity of complete individual garlics, and the existence of bad individual garlics in the whole bulb of garlic were selected as quality grading factors. Quality discrimination algorithms with machine vision techniques were developed and verified for the four factors based on morphological and physical features of whole bulbs of garlic. Based on the results, the size discrimination by the projected area of a whole bulbs of garlic suggested four grading levels and the algorithm for predicting the number of complete individual garlics based on the peaks on its projected boundary showed ${\pm}$0.78 prediction error. In addition, the uniformity represented by coefficient of variation could be divided into four levels, but the algorithm for discriminating the existence of bad individual garlics in a whole bulb of garlic was not effective.

  • PDF

COMPARATIVE STUDIES ON THE RETENTIVE VALUES OF VARIOUS DENIAL CEMENTS USED TO RETAIN ORTHODONTIC BANDS (교정용 BANDS 접착에 사용되는 각종 치과용 시멘트의 유지력에 관한 비교 연구)

  • Kim, Joo Young;Ryu, Young Kyu
    • The korean journal of orthodontics
    • /
    • v.11 no.2
    • /
    • pp.151-160
    • /
    • 1981
  • The purpose of this study was to compare the retentive values of various dental cements used for cementing the orthodontic bands on the teeth. Sound freshly extracted human premolar teeth were selected for the study. Eleven commercial dental cements (Zinc phosphate, reinforced Zinc-oxide eugenol, Carboxylate and Glass ionomer cements) were handled under standardized conditions. All cemented speciments were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C$ and more than $95\%$ relative humidity and tested after 24 hours and 1 week each. The force required to remove the cemented orthodontic bands from the teeth was determined on an Instron Universal Testing Machine using a modified specimen holding device with a cross-head speed of 0.20mm/min. The results obtained were as follows: 1, The retentive values of the band cemented with zinc phosphate cements and carboxylate cements were considerably higher than those of the reinforced zinc oxide-eugenol and glass ionomer cements. 2. There was no significant difference between the retentive value of carboxylate cements as compared with zinc phosphate cements. 3. The retentive value of the reinforced zinc oxide eugenol cements was lowest all of the coements. The retentive values expressed for all cements up to at least one week were highly but no significant difference was found between the 24-hour and 7 day time intervals.

  • PDF

Comparative Analysis of Surface-mounted and Interior Permanent Magnet Synchronous Motor (표면부착형 / 매입형 영구자석 동기 전동기의 비교 분석)

  • Park, Hyung-Il;Kim, Kwan-Ho;Shin, Kyung-Hun;Jang, Seok-Myeong;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.987-994
    • /
    • 2016
  • In this paper, we present a comparative analysis of surface-mounted permanent magnet synchronous motors (SPMSM) and interior permanent magnet synchronous motors (IPMSM). First, we use 2D finite element analysis (FEA) to analyze models satisfying the same rated conditions according to the torque-speed curve characteristics, which are determined from the operating conditions. Next, we manufacture an SPMSM and IPMSM having good performances from an electromagnetic perspective based on analysis results, namely the cogging torque, torque ripple, and efficiency. We analyze both of the manufactured machines when they are connected back-to-back and when they are used as a motor and a generator, respectively. The motor is driven by a commercial inverter and the generator is connected to a three-phase resistance load bank. Finally, based on experimental results, which include the total harmonic distortion (THD) of the back electro-motive force (EMF), cogging torque, efficiency, and mass, we determine the motor that is most suitable under requirements.

Development of CFRP Tubes for the Light-Weight Propeller Shaft of 4WD SUV Vehicles (4륜구동 SUV 차량용 구동축 경량화를 위한 CFRP 튜브 개발)

  • Na, Hae-Jung;Chun, Jin-Sung;Cho, Kyu-Sang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.32-38
    • /
    • 2018
  • In this study, the one-piece propeller shaft composed of carbon/epoxy was designed and manufactured for 4 wheel drive automobiles that can bear the target torsional torque performance of 3.5kN.m. For the CFRP tube, braiding machine was used to weaving carbon fiber and it was formed the braided yarns with the braid angle ${\pm}45^{\circ}$ and axial yarns to improve strength of the lengthwise direction. The final CFRP tube of propeller shaft was evaluated through the torsional torque test. The CFRP propeller shaft satisfied requirement of the target torsional maximum torque of 3.5kN.m. Also, it was found that the one-piece composite propeller shaft with CFRP tube had 30% weight saving effect compared with a two-piece steel propeller shaft.

Effect of fiber glass on the physical properties of denture base resins (화이버 글라스가 의치상 레진의 기계적 특성에 미치는 영향)

  • Park, Yeon-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.35 no.2
    • /
    • pp.97-103
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the effect of addition of fiber glass on the physical properties of silanized fiber mesh and non silanized mesh of denture base resins. Methods: The denture base resins were used in this study heat curing acrylic resins(Vertex Rs, Lucitone 199, $20{\times}80mm$) and fiber glass(SES, Green B&D co., Ltd, $20{\times}80mm$) were used as reinforcement. The specimens were stored in distilled water at $37{\pm}2^{\circ}C$ for 72 hours before test. Bending strength and tensile strength were measured by an universal testing machine(Instron 4301, Instron Corp.). Penetration distribution on fiber was observed by scanning electron microscopy(JSM 840A, Jeol Ltd). Results: The bending strength and modulus were increased by 30% after adding fiber glass on denture base resins. Tensile strength showed significant increasing by adding fiber glass on denture base resins. Conclusion: In this study, Addition of silanized fiber in denture base resins were improved physical properties. we confirmed the fiber glass possibility of the replacement about conventional materials.