• Title/Summary/Keyword: PM loss

Search Result 1,280, Processing Time 0.023 seconds

Comparison of Meat Quality Characteristics and Proteolysis Trends associated with Muscle Fiber Type Distribution between Duck Pectoralis Major and Iliotibialis Muscles

  • Cheng, Huilin;Song, Sumin;Park, Tae Sub;Kim, Gap-Don
    • Food Science of Animal Resources
    • /
    • v.42 no.2
    • /
    • pp.266-279
    • /
    • 2022
  • This study was conducted to evaluate the proteolysis trends and change in meat quality during 10 days of cold storage in duck M. pectoralis major (PM) and M. iliotibialis (IL). Duck IL had a higher pH and greater degree of lightness but lower cooking loss than PM (p<0.05). During the 10-day cold storage, the pH value of PM declined significantly (p<0.05), while the meat quality traits of IL were not affected by cold storage (p>0.05). In PM, the redness increased from day 1 to day 5, while cooking loss was lower on day 10 compared to day 5 (p<0.05). There were no significant differences in the activities of cathepsin B and proteasome 20S during cold storage (p>0.05). The activity of calpains declined gradually during 10 days of storage (p<0.05), and the activity of calpains in PM was higher than that in IL (p<0.05). A total of 5,155 peptides were detected and derived from 34 proteins of duck PM muscle, whereas 4,222 peptides derived from 32 proteins were detected from duck IL muscle. Duck PM muscle was composed only of fast type of muscle fiber, whereas IL muscle was composed of both slow and fast types. The proteins responsible for glycolysis or myofibrillar proteins were closely related to changes in meat color or water-holding capacity during cold storage. These results suggest that changes in meat quality characteristics during cold storage are closely related to protein degradation, which is also related to the distribution of muscle fiber types.

A Comparison Study of Heat Loss Characteristics in Monofilament and Multifilament Superconducting Coils Driven with AC Currents (단일필라멘트와 다중필라멘트 초전도 코일의 교류 전류에 의한 발열 특성 비교 평가)

  • Hwang, S.M.;Kim, K.;Kang, C.S.;Lee, S.J.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.111-116
    • /
    • 2011
  • Since superconducting wires have no resistance, electromagnets based on the superconducting wires produce no resistive heating with DC current as long as the current does not exceed the critical current of the wire. However, unlike resistive wires, superconducting wires exhibit AC heat loss. Embedding fine superconducting filaments inside copper matrix can reduce this AC loss to an acceptable level and opens the way to AC-capable superconducting coils. Here, we introduce an easy and accurate method to measure AC heat loss from sample superconducting coils by measuring changes in the rate of gas helium outflow from the liquid helium dewar in which the sample coil is placed. This method provides accurate information on total heat loss of a superconducting coil without any size limit, as long as the coil can fit inside the liquid helium dewar. With this method, we have evaluated AC heat loss of two superconducting solenoids, a 180-turn solid NbTi wire with 0.127 mm diameter (NbTi coil) and a 100-turn filamented wire with 1.4 mm diameter where 7 NbTi filaments were embedded in a copper matrix with copper to NbTi ratio of 6.7:1 (NbTi-Cu coil). Both coils were wound on 15 mm-diameter G-10 epoxy tubes. The AC heat losses of the NbTi and NbTi-Cu coils were evaluated as $53{\pm}4.7\;{\mu}W/A^2Hzcm^3$ and $0.67{\pm}0.16\;{\mu}W/A^2Hzcm^3$, respectively.

A STUDY OF MARGINAL BONE RESORPTION AROUND IMPLANTS AFTER IMMEDIATE LOADING (Immediate loading하에서 치근형 임프란트 주위 변연골 흡수에 대한 연구)

  • Kim Sung-Hyen;Han Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.376-390
    • /
    • 2001
  • Alveolar bone changes after immediate loading on implants up to one year were observed by means of standard intraoral X-ray measurement which were taken at 3 month intervals. At the same time, bone density changes were observed according to digital subtraction method which is a becoming a more and more promising diagnostic tool for implants. Following results were obtained ; 1. There was no significant difference in the amount of alveolar bone loss implant type, sex and implant diameter, but there was difference according to case selection. In fully bone anchored prostheses cases, bone loss was $1.16{\pm}0.15m$ whereas, in partial edentulous cases, it was $1.84{\pm}0.08mm$. 2. Alveolar bone loss after immediate loading showed a higher degree of bone loss than after submerged loading in the initial three months. But there were no significant difference at the 12th month. 3. According to the one year bone density change observation at the alveolar bone surrounding the implant, significant change was observed vertically, whereas no significant change could observed horizontally. According to the above mentioned results, we can conclude that immediate loading of implants results in a higher degree of alveolar bone loss in one year than submerged loading. But since alveolar bone loss rate decreases to a reasonable rate after the initial 3 months of rapid bone loss, immediate loading of implants seems to be an acceptable treatment modality for patients with good bone conditions. Fully bone anchored cases showed an favorable outcome, but partial edentulous cases showed more bony resorption. So this cases considered in case selections. Bone density changes observation in the study was performed for only one year therefore a more longitudinal observation may be studied.

  • PDF

Measurements on the Propagation Path Loss Exponent at Maritime VHF Channel Using Single Carrier Signal (단일 반송파를 이용한 해상 VHF 채널의 전파 경로 감쇠 지수 측정)

  • Kim, Seung-Geun;Kim, Sea-Moon;Yun, Changho;Lim, Yong-Kon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.7
    • /
    • pp.1450-1456
    • /
    • 2015
  • The received signal strengths according to the propagation distance between a transmitting shore station with a 53 m antenna hight and a receiving ship station with about 6m antenna hight from 700 m upto about 20 km are measured at ship's moving velocity of $5{\pm}1m/s$ using a single carrier signal at 150.0625MHz. In this paper, the path loss exponents at the propagation distance from 700 m to 20km are estimated via minimum-mean-square-error method using the measurements of the received signal strength, and the mean of the estimated path loss exponent become 3.79. The estimated propagation path loss exponents is similar to that calculated based on the field-strength values from 2 km to 20 km in Annex 2 of ITU-R P.1546-4, which is measuring results at maritime VHF at 100 MHz carrier frequency. Therefore, the estimated propagation path loss exponent shall be used as the expected path loss exponents for summer in costal area of South Sea of Korea.

Studies on the Processing Characteristics of Poultry Meat -1. Water Holding Capacity of Chicken Muscle- (가금육(家禽肉)의 가공적성(加工適性)에 관(關)한 연구(硏究) -1. 계육(鷄肉)의 보수력(保水力)-)

  • Sung, S.K.
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.2 no.1
    • /
    • pp.55-59
    • /
    • 1973
  • This experiment was carried out to improve on the simple and conventional processing method by studying the characteristics of poultry meat. For the experiment, 20 hens culled and 20 broilers were slaughtered and divided into the following five groups; whole carcass, skinned carcass, debonned carcass, thigh muscle and breast muscle. Each group was ground by the super grinding machine. The results tobtained are summarized as follows; (1) The percentage of the ready-to-cook of cull hens and broilers was $64.32{\pm}2.11,\;67.96{\pm}1.16$, and of the water uptake, $105.43{\pm}1.9,\;104.13{\pm}0.2$, respectively. (2) In the chemical composition, broiler meat showed high moisture content and a little low fat content, as compared with cull hen meat. By groups, whole carcass ground meat contained lower maisture content, and higher fat and ash content than thigh muscle and breast muscle. (3) Thigh muscle and breast muscle group was higher than the other and whole carcass group was lower for the relative WHC and water retention.(4) The higher temperature the higher cooking loss percentage in all groups, and whole carcass group was the highest cooking loss percentage among the all groups.(5) The significant difference was little observed for the relative WHC, water retention and cooking loss percentage by groups between cull hen and Broiler.

  • PDF

CLINICAL STUDY ON THERAPEUTIC EFFECTS OF DECACIFIED PREEZE DRIED BONE ALLOGRAFT IN INTRABONY DEFECTS (골내치주낭에서 탈회냉동건조골 동종이식시 이식효과에 대한 임상적 연구)

  • Kim, Sung-Hee;Kim, Chong-Kwan;Chai, Jung-Kiu;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.3
    • /
    • pp.618-632
    • /
    • 1994
  • The ultimate goal of periodontal therapy is promoting the regeneration of lost periodontal tissue. The purpose of this study is to evaluate the effect of treatment using decalcified freeze dried bone allograft as a bone graft material. 47 intrabony defects from 27 patients with clinical diagnosis of chronic periodontitis were selected among those 24 defects were treated via flap operation only and designated as the control group, the other 23 defects were treated with decalcified freeze dired bone allografting via flap operation and designated as the experimental group. Clinical parameters including probing depth, loss of attachment, probing bone level and gingival recession have been recorded at 6th months, and the significance of the changes has been analyzed. The results are as follows : 1. Probing depths were reduced significantly in both control group($2.75{\pm}0.99mm$) and experimental group($3.69{\pm}0.97mm$) postoperatively(p<0.01). Experimental group showed significantly higher decrease compared to the control group(p]0.01). 2. Loss of attachment showed statistically significant decrease in both control group($1.77{\pm}1.08mm$) and experimental group postoperatively($2.70{\pm}1.55mm$). Experimental group showed significantly higher decrease compared to the control group(p]0.05). 3. Probing bone levels were reduced with statistically significance in both control group($1.08{\pm}0.97mm$) and experimental group($4.00{\pm}1.41mm$) postoperatively(p<0.01). Experimental group showed significantly higher decrease compared to the control group(p<0.01). 4. Gingival recession showed statistically significant increase in the control group($1.21{\pm}0.72mm$) and experimental group($1.00{\pm}1.09mm$) postoperatively(p<0.01). There was no statistical significance between the control group and the experimental group. On the basis of these results, treatment using allogenic decalcified freeze dried bone is effective in reducing probing depth, loss of attachment and probing bone level. Therefore allogenic decalcified freeze dried bone is an effective bone graft material in periodontal regeneration.

  • PDF

A RF Microstrip Balun Using a Wilkinson Divider and 3-dB Quadrature Couplers (월킨슨 분배기와 90도 위상차 분배기를 이용한 RF 마이크로스트립 발룬)

  • Park Ung-Hee;Lim Jong-Sik;Kim Joung-Myoun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.3 s.94
    • /
    • pp.246-252
    • /
    • 2005
  • A RF microstrip balun having low transmission loss for the balanced receiving dipole antenna is designed and fabricated using a three-section Wilkinson divider and two 3-dB quadrature couplers. It considers two types of the three-section Wilkinson dividers, the Cohn's optimum three-section structure and the miniaturized three-section structure, for wideband power splitting. Also, two 3-dB quadrature couplers for 180 degrees of phase difference adopt a twist-wire coaxial cable. The fabricated first balun having the Cohn's optimum three-section Wilkinson divider has 0.5 dB of transmission loss, $\pm$0.2 dB of amplitude imbalance, and 180$\pm$2.3 degrees of phase imbalance over 400 to 1000 MHz by measurement. The second one using the miniaturized three-section Wilkinson divider shows 1.0 dB of transmission loss, $\pm$0.7 dB of amplitude imbalance, and 180$\pm$8.8 degrees of phase imbalance over the same frequency band.

Pilot Clinical Trial to Evaluate the Efficacy of Needle-Embedding Acupuncture Therapy at Gokji(LI11) on TEWL (곡지혈 매선침 시술이 경피수분 손실량에 미치는 영향)

  • Lee, Ho Chan;Jung, Mi Young;Choi, Jung Hwa;Jeong, Min Yeong;Park, Soo Yeon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.32 no.4
    • /
    • pp.291-297
    • /
    • 2018
  • The purpose of pilot clinical trial is to evaluate the efiicacy and safety of Needle-Embedding acupuncture therapy on TEWL(Transepidermal Water Loss) and Skin hydration. A total of 24 human who visited Dongshin Oriental Medical Center from December 1st, 2016 to July 31st, 2017 were included in the pilot clinical trial. Needle-Embedding acupuncture therapy performed at Gokji(LI11). We observed change of TEWL(Transepidermal Water Loss), Skin hydration before and after Needle-Embedding acupuncture therapy. In the primary endpoint, index of TEWL showed a statistically insignificant decline ($8.5{\pm}2.12{\rightarrow}7.8{\pm}1.53g/h/m^2$). Index of skin hydration showed a statistically significant result ($38.2{\pm}6.77{\rightarrow}36.8{\pm}6.64$). To evaluate the safety, Adverse events and Vital sign check were conducted and there were no problem. And when the physical response, self-awareness, skin system, musculoskeletal pain, and other abnormal responses were assessed 60 minutes and 24 hours and 7 days after Needle-Embedding acupuncture therapy at Gokji(LI11) for stability assessment, Adverse events disappeared during a pilot clinical trial. According to the above pilot clinical trial, it is suggested Needle-Embedding acupuncture therapy were effective for Skin moisturizing and safe.

Effects of Pre-drying Process on the Quality of 'Fuyu' Persimmons (예건 처리 온도에 따른 단감(부유)의 품질 변화 조사)

  • Park, Sung Jin;Cho, Kwang Sik;Kim, Jun Tae
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.21 no.2
    • /
    • pp.79-84
    • /
    • 2015
  • Pre-drying of 'Fuyu' persimmon was performed right after harvesting from a farm. Pre-drying conditions were varied with room temperature (RT) for 1 day to 7 days, low temperature (LT, at $20{\sim}30^{\circ}C$) for 1 day to 4 days, high temperature (HT, at $30{\sim}40^{\circ}C$) for 3 h to 12 h, and ultra-high temperature (UT, at $50{\sim}60^{\circ}C$) for 30 min to 120 min. Weight loss of pre-dried persimmon was increased from 1.62% up to 2.96% with increased pre-drying temperature and time. Pre-drying at RT resulted more significant weight loss of persimmon compared to that of pre-drying at HT. Minimum firmness loss of persimmon stored at $0^{\circ}C$ for 100 days was obtained at the condition of HT for 6 h. Rate of peel blackening was decreased from 31.5% to 16.4% and 10.9% by pre-drying at HT for 6 h and 9 h, respectively.

  • PDF

X-band Compact Digital Phase Shifter Design (X 대역 소형 디지털 위상 천이기 설계)

  • 엄순영;전순익;육종관;박한규
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.9
    • /
    • pp.907-915
    • /
    • 2002
  • In this paper, a compact digital phase shifter to be used an active phased array antenna system for satellite communications was proposed. The even and odd mode analysis for a given reflection-type phase shifter, which uses a folded hybrid coupler as a base element, was performed and the design parameters were derived. Also, to verify experimentally the electrical performances of the proposed structure, X-band 4-bit digital phase shifter was designed and fabricated using Teflon soft substrate $({\varepsilon}_r; =\;2.17)$. Its circuit size was less than 3.5 cm $\times$ 3.0 cm, and it exhibited at least 50 % size reduction as compared with the conventional unfolded configuration. The experimental results of the fabricated phase shifter showed that the average insertion loss and insertion loss variation were less than 3.5 dB, $\pm$ 0.6 dB within the operating band, 7.9 ~ 8.4 GHz, respectively. And, input and output return loss were more than 10 dB, respectively. Also, the phase response of the phase shifter showed 4-bit operation with $\pm$3$^{\circ}$ rms phase error.