• Title/Summary/Keyword: PM collection

Search Result 431, Processing Time 0.025 seconds

Design and Performance Evaluation of a Three Stage Impactor (대기 에어로졸 측정용 3단 임팩터의 설계 및 성능평가)

  • 지준호;배귀남;황정호
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.6
    • /
    • pp.441-450
    • /
    • 2001
  • A three stage impactor with the cutoff diameters of 1, 2.5, and 10$\mu\textrm{m}$ in aerodynamic diameter was developed and tested. The gravimetric method and the particle counting method were utilized to evaluate the collection performance of each stage. A vibrating orifice aerosol generator was employed to generate monodisperse test aerosols larger that 2$\mu\textrm{m}$ in diameter. Polystyrene latex (PSL) particles smaller than 2$\mu\textrm{m}$ in diameter were generated by an atomizer and the particle number concentration was measured by an Aerodynamic Particle Sizer Spectrometer. The experimental cutoff diameters obtained from the particle collection efficiency curves are in good agreement with the designed values. The square roots of Stokes number at 50% collection efficiency for stage 1, 2, and 3 are 0.42, 0.48, and 0.45, respectively. Effects of the particle bounce and the impaction plate on the collection efficiency were investigated. The collection efficiency curves including effect of the particle bounce were also compared with those of the MOUDI cascade impactor.

  • PDF

Anomaly detection in particulate matter sensor using hypothesis pruning generative adversarial network

  • Park, YeongHyeon;Park, Won Seok;Kim, Yeong Beom
    • ETRI Journal
    • /
    • v.43 no.3
    • /
    • pp.511-523
    • /
    • 2021
  • The World Health Organization provides guidelines for managing the particulate matter (PM) level because a higher PM level represents a threat to human health. To manage the PM level, a procedure for measuring the PM value is first needed. We use a PM sensor that collects the PM level by laser-based light scattering (LLS) method because it is more cost effective than a beta attenuation monitor-based sensor or tapered element oscillating microbalance-based sensor. However, an LLS-based sensor has a higher probability of malfunctioning than the higher cost sensors. In this paper, we regard the overall malfunctioning, including strange value collection or missing collection data as anomalies, and we aim to detect anomalies for the maintenance of PM measuring sensors. We propose a novel architecture for solving the above aim that we call the hypothesis pruning generative adversarial network (HP-GAN). Through comparative experiments, we achieve AUROC and AUPRC values of 0.948 and 0.967, respectively, in the detection of anomalies in LLS-based PM measuring sensors. We conclude that our HP-GAN is a cutting-edge model for anomaly detection.

Evaluation on Performance of an Electrostatic Diesel PM Trap Device and Its Application to Diesel Engine After-treatment (정전 방식 디젤 PM 포집 장치 성능 및 엔진 적용성 평가)

  • Kim, Hak-Joon;Han, Bang-Woo;Kim, Yong-Jin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.6
    • /
    • pp.176-183
    • /
    • 2008
  • Performance of electrostatic diesel PM filtration systems (E-DPS) with different types has been tested using the carbon particles generated by spark discharge in laboratory. Among the five electrostatic precipitators, the multiple wires cylindrical E-DPS with the highest collection efficiency and relatively lower differential pressure at the flow rate of $1\;m^3$/min, as an applicable device to diesel engine as an after treatment system, has been combined with another collection cylinder to improve the collection efficiency of diesel particulate matters generated from diesel engines. The multiple wires cylindrical E-DPS combined with the cylindrical collector showed the collection efficiency of more than 60% at the engine speed of 2,000 rpm with the engine loads of 25 and 50%.

Embryo Collection, Transfer and Pregnancy of Riding Horses : First Successful Case in Korea

  • Park, Yong-Soo;Yang, Jae-Hyuk;Cho, Young-Jae;Oh, Dong-Yep;Cho, Gil-Jae
    • Journal of Embryo Transfer
    • /
    • v.32 no.2
    • /
    • pp.59-64
    • /
    • 2017
  • Embryo transfer (ET) could be a relevant tool for genetic improvement programs in horses similar to those already underway in other species and produce multiple foals from the same mare in one breeding season. However, there have been no reports describing equine embryo transfer performed in Korea. In the present study, we performed an equine embryo collection and transfer procedure for the first time. We examined the embryo collection and pregnancy, size of embryo during the incubation period after collection, and progesterone (P4) and estradiol-$17{\beta}$ (E2) concentrations in mare's serum at embryo collection and transfer. A total of 16 donors responded to estrus synchronization; estrus was induced in 12 donors and 4 recipients, and artificial insemination was successful in 10 donors and six blastocysts were collected from donors. Of these blastocysts, we monitored the size of blastocysts for 3 day during incubation and transferred 2 blastocysts to a recipient, with 1 successful pregnancy and foal achieved. The dimensions of equine embryo at day 7 to day 9 were $409{\mu}m$, $814{\mu}m$ and $1,200{\mu}m$. The serum P4 and E2 concentrations were $7.91{\pm}0.37ng/{\mu}L$ and $45.45{\pm}12.65ng/{\mu}L$ in the donor mare, and 1$6.06{\pm}3.27ng/{\mu}L$ and $49.13{\pm}10.09ng/{\mu}L$ in the recipient mare.

Characteristics of particulate matter collection efficiency and ozone emission rate of an electrostatic precipitator by thickness of high-voltage electrode and distance of collection plates (고전압 전극 두께와 집진판 간격에 따른 전기집진기의 미세먼지 집진효율 및 오존발생 특성)

  • Lee, Jae-In;Woo, Sang-Hee;Kim, Jong Bum;Lee, Seung-Bok;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.171-180
    • /
    • 2018
  • To optimize the shape of the electrostatic precipitator for the removal of particulate matter in subway environments, the wind-tunnel experiments were carried out to characterize collection efficiency and ozone emission rate. As a standardized parameter, power consumption divided by the square of flow velocity, was increased, the $PM_{10}$ collection efficiency increased. If the standardized parameter is higher than 1.0 due to high power consumption or low flow velocity, increase in thickness of electrodes from 1 to 2 mm, or increase in distance of collection plates from 5 to 10 cm did not change the $PM_{10}$ collection efficiency much. Increase in thickness of high-voltage electrodes, however, can cause decrease in $PM_{10}$ collection efficiency by 28% for low power consumption and high flow velocity. The ozone emission rate decreased as distance of collection plates became wider, because the ozone emission rate per unit channel was constant, and the number of collection channels decreased as the distance of collection plates increased. When the distance of collection plates was narrow, the ozone emission rate increased with the increase of the thickness of electrodes, but the difference was negligible when the distance of collection plates was wide. It was found that the electrostatic precipitator having a thin high-voltage electrodes and a narrow distance of collection plates is advantageous. However, to increase the thickness of high-voltage electrodes, or to increase the distance of collection plates is needed, it is necessary to increase the applied voltage or reduce the flow rate to compensate reduction of the collection efficiency.

Use of Antibody Displayed Phage for the Detection of Dextran Using a Dipstick Assay and Transmission Electron Micrograph

  • Kim Du-Woon;Day Donal F.
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.8
    • /
    • pp.1316-1319
    • /
    • 2006
  • An antibody displayed phage collection (SBAE-2R), screened from a human synthetic phage antibody library (Fab 21ox), was used for the determination of dextran. The dextran-binding affinity was determined by serologically specific transmission electron microscopy (TEM) and a paper dipstick assay. The phage collection was distributed over the dextrancoated grids with 39$\pm$25 phages/$\mu$m$^2$ on the grids. Phages were not seen on dextran-coated grids exposed to the Fab 2lox phage library. The phage collection (SBAE-2R) produced 54$\pm$3 color normalized intensity (N.I.) from 125 ppm to 1,000 ppm of dextran and 5$\pm$1 (N.I.) for 63 ppm of dextran in a paper dipstick assay. This research extends the analytical options for dextran analysis by antibody displayed phage with a minimum of equipment usage.

A Study on Protection Plan of Eutrophication in Fresh Water Environment by Development of Methods for Algal Growth Potential test (I) -Morphology and Growth Characteristics of Isolated algae- (조류생산잠재력조사 방법개발에 의한 육수환경의 부영양화 방지대책에 관한 연구(I) -순수분리종의 형태 및 증식특성-)

  • 위인선;나철호;이종빈;주현수
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.18-27
    • /
    • 1997
  • The isolation, morphological study and growth characteristics of the algae were investigated from Lake Chuam. The isolated algae were applied the Agal Growth Potential test. The method of isolation and purification of the algae were used to Agar plating(AP), nutrient enrichment(NE), dilution(DI) and micro capillary technique(MC). Total isolated algae were 21 species. They were composed of Cyanophyceae, Dinophyceae, Bacillariophyceae, Euglenophyceae and Chlorophyceae. The numbers of algal strain by isolation technique were highest in dilution(21 species), and those of the rests were showed in order of NE > MC > AP. The sizes of isolated Selenastrum and Scenedesmus were $1.8\pm 1.4 \mu m$, $3.3\pm 0.9 \mu m$ in diameter and $6.4\pm 2.3 \mu m$, $13.6\pm 1.9 \mu m$ in length respectively. The morphology of isolated algae and NIES-collection strain was very similar each other, but the size was smaller isolated algae than that of NIES-collection. The optimum culture condition of isolated Selenastrum and Scenedesmus was about 30$\circ$C(25$\circ$C-35$\circ$C) in temperature and the maximum growth was appeared between 7,000 lux and 8,000 lux in the light intensity. The comparison of $\mu$(specific growth rate) on the concentration of nutrients such as nitrate and phosphate, isolated Selenastrum was appeared maximum it at 1.0 mg $NO_3-N/l$ but NIES-collection strain was showed 95% of maximum it at same nitrate concentration. Maximum g of isolated algae and NIES-collection strain in Scenedesmus onto nitrate concentration were very similar with the result of selenastrum. The specific growth rates of isolated algae and NIES-collection strain on the gradient concentration of phosphate were showed 0.72/day and 0.70/day at 0.02 mg $PO_4-P/l$ in Selenastrum but those of Scenedesmus were appeared 0.61/day and 0.57/day at same concentration $PO_4-P$.

  • PDF

Improving light collection efficiency using partitioned light guide on pixelated scintillator-based γ-ray imager

  • Hyeon, Suyeon;Hammig, Mark;Jeong, Manhee
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1760-1768
    • /
    • 2022
  • When gamma-camera sensor modules, which are key components of radiation imagers, are derived from the coupling between scintillators and photosensors, the light collection efficiency is an important factor in determining the effectiveness with which the instrument can identify nuclides via their derived gamma-ray spectra. If the pixel area of the scintillator is larger than the pixel area of the photosensor, light loss and cross-talk between pixels of the photosensor can result in information loss, thereby degrading the precision of the energy estimate and the accuracy of the position-of-interaction determination derived from each active pixel in a coded-aperture based gamma camera. Here we present two methods to overcome the information loss associated with the loss of photons created by scintillation pixels that are coupled to an associated silicon photomultiplier pixel. Specifically, we detail the use of either: (1) light guides, or (2) scintillation pixel areas that match the area of the SiPM pixel. Compared with scintillator/SiPM couplings that have slightly mismatched intercept areas, the experimental results show that both methods substantially improve both the energy and spatial resolution by increasing light collection efficiency, but in terms of the image sensitivity and image quality, only slight improvements are accrued.

Collection Characteristics of Particulate Matters from Biomass Burning by Control Devices: Mainly Commercial Meat Cooking (생물성연소에서 발생하는 미세먼지의 장치별 집진 특성: 고기구이를 중심으로)

  • Park, Seong-Kyu;Choi, Sang-Jin;Park, Geon-Jin;Kim, Jin-Yun;Bong, Choon-Keun;Park, Seong-Jin;Kim, Jong-Ho;Hwang, Ui-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.641-649
    • /
    • 2011
  • The aim of this study is to understand the characteristics of exhausting particulate matters (PM) and to control emitted PM from meat cooking restaurants. We found that $PM_{2.5}$, $PM_{5.0}$ occupy 69.2% and 98.6% of total PM from pork cooking, respectively. Therefore, we can see that it is not easy to remove PM generated from a pork cooking process. The collection efficiencies of various control devices, which are a condensing scrubber, a cyclone, an impactor, an oil filter and an electrostatic precipitator (ESP), were measured and compared. ESP had the highest collection efficiency (88.6%) and condensing scrubber had the lowest one (68.0%). However, the system recovering property should be considered to choose a control device because PM from meat cooking process are extremely stickiness. Therefore, we can recommend that ESP following an impactor or a cyclone is the best combination to remove PM generated from meat cooking restaurants.

Comparative Study on the Efficiency Test Using Remodeled Bubble Generating Pump for Aquarium Fish and Established Air Sampling Pump (관상어용 기포발생기를 개조한 시료채취 장치와 기존의 시료채취기와의 성능 비교)

  • Jang, Bong-Ki;Chun, Jae-Young;Son, Bu-Soon;Lee, Jong-Wha;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.183-191
    • /
    • 2005
  • This study is designed to compare the performance of established samplers (personal air sampler and MiniVOL portable air sampler) commonly used in the air environment or work environment with that of the sampler made by remodeling the air bubble generator for aquarium fishes. Sampling method used in this study is the filter collection method for PM10 and total suspended particles (TSP), the liquid collection method for sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$), and the solid collection method for toluene, respectively. There is not a significant difference in the average concentration of TSP between the Gilian personal air sampler (1st, $0.316{\pm}0.095$; 2nd $0.191{\pm}0.090$; 3rd, $0.185{\pm}0.073mg/m^3$) and the remodeled sampler (1st, $0.317{\pm}0.106$, 2nd $0.201{\pm}0.050$; 3rd $0.189{\pm}0.081mg/m^3$). There are also not significant differences in the average concentration of PM10 among the Gilian personal air sampler ($0.058{\pm}0.006mg/m^3$), the remodeled sampler ($0.052{\pm}0.008mg/m^3$) and the MiniVOL portable air sampler ($0.054{\pm}0.007mg/m^3$). The average concentration of the SO2 by the established sampler and the remodeled one is $3.79{\pm}0.21ppb$ and $3.45{\pm}0.15ppb$, respectively. In addition, there are not sigmficant differences in the average concentration of the NO2 between the Gilian personal air sampler (1st, $0.325{\pm}0.068$; 2nd $0.341{\pm}0.206$; 3rd, $2.971{\pm}0.078{\mu}g/m^3$) and the remodeled sampler (1st, $0.300{\pm}0.062$; 2nd $0.332{\pm}0.144$, 3rd, $2.968{\pm}0.085{\mu}g/m^3$). There are not significant differences in the average concentration of toluene between the Gilian personal air sampler (1st, $0.499{\pm}0.072$; 2nd $0.598{\pm}0.112$; 3rd $2.284{\pm}0.077{\mu}g/m^3$) and the remodeled sampler (1st, $0.463{\pm}0.133$; 2nd $0.603{\pm}0.082$; 3rd $2.353{\pm}0.115{\mu}g/m^3$). From these results, we can conclude that the performance of the remodeled sampler is not different from that of established samplers. There is possibility that the remodeled sampler can be used as a alternative device for Gilian personal air sampler in area and personal air sampling.