• Title/Summary/Keyword: PLS-II

Search Result 65, Processing Time 0.035 seconds

Diagnostic Instruments of PLS-II

  • Kim, Chang-Beom;Kim, Do-Tae;Choe, Jae-Yeong;Lee, Heung-Su;Park, Eung-Su;Sin, Seung-Hwan;Hwang, Jeong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.527-527
    • /
    • 2012
  • In the Pohang Light Source (PLS), a major upgrade (PLS-II) of existing machine had been performed in last 3 years. Big improvements in beam parameters are expected from this major upgrade and various diagnostic instruments were installed to measure them. These include beam position monitor, beam current monitor, tune monitor, scraper, beam loss monitor, photon beam monitor, beam size monitor, streak camera, and so on. In this work, we would like to briefly introduce diagnostic instruments of the PLS-II and present measurement results in the commissioning process of the PLS-II.

  • PDF

PLS-II 저장링 진공시스템 건설

  • Park, Jong-Do
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.100-100
    • /
    • 2011
  • 포항가속기연구소에서는 제3세대 방사광가속기 성능향상사업(PLS-II)을 수행하고 있다. 2010년 12월 말 PLS (Pohang light Source) 해체를 시작한 후 2011년 6월 말 까지 PLS-II 저장링 건설을 완료 하였으며 현재 시운전을 계속하고 있다. 성능향상은 기존 PLS 건물을 그대로 유지한 채 삽입장치를 20기 까지 설치하도록 변경하도록 하였으며 전자빔의 에너지는 2.5 GeV에서 3 GeV로, 빔전류는 200 mA에서 400 mA로 증가시키는 반면 빔에미턴스는 약 1/3로 줄인다. 저장링 진공시스템은 저장된 전자가 충분한 시간동안 저장되도록 운전시 2${\times}$10-9 Torr 이하의 진공도를 가지도록 건설하였다. 본 발표에서는 지난 2년 동안 진행되어온 PLS-II 저장링 진공시스템에 대한 설계, 제작, 시험, 설치, 시운전 및 건설 일정/인력에 등에 대하여 보고하며 PLS 건설 및 해체에 대한 내용도 보고한다.

  • PDF

PLS-II 진공시스템 1차 시운전

  • Park, Jong-Do;Ha, Tae-Gyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.241-241
    • /
    • 2013
  • PLS-II 저장링 진공시스템은 2011년 6월 설치 완료 후 2011년 7월부터 2012년 초 까지 1차 시운전을 마쳤다. PLS-II 저장링 진공시스템은 누적 전류 50 Ah 운전 후, 3 GeV, 400 mA 전자빔 운전 시 평균 진공도 $2{\times}10^{-9}$ mbar를 유지도록 설계되어 빔-기체 산란 수명을 20 시간 이상 확보하도록 설계하였다. 지금까지의 간략한 운전 이력과 진공시스템의 성능을 보고하고 최근 방사광 가속기에서 중요하게 취급하는 진공용기(특히, 빔전류 측정 진공용기)의 기계적 안정도, 변위 등과 BPM TE mode noise suppression 등을 보고하고자 한다.

  • PDF

Design and Implementation of Solid-State Kicker Modulator for PLS-II (PLS-II 용 반도체 스위치 기반 키커 펄스 모듈레이터 설계 및 제작)

  • An, Suk-Ho;Kong, Hyung-Sup;Park, Wung-Hoa;Lee, Byung-Joon
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.307-308
    • /
    • 2019
  • The Pohang Light Source (PLS) - II is a 3 GeV third-generation synchrotron radiation facility. To inject electron beam from LINAC, a kicker modulator system and kicker magnets are installed in the PLS-II storage ring tunnel. The injected beam then falls into the storage ring beam dynamic aperture. This paper describes the design and implementation of the solid-state kicker modulator for PLS-II. The solid-state kicker modulator is consisted of high voltage solid state switch stacks. the technical considerations of the solid-state switch stacking for kicker modulator is discussed. The achieved capability of the solid-state kicker modulator demonstrates that is fulfills the design requirement of providing half-sine pulsed current of 10kA (peak), 6us (Base-width), with jitter < 2ns (Standard deviation). simulation and experimental results are presented to demonstrate the performance of the solid-state kicker modulator.

  • PDF

PLS-II separator the vacuum electron gun beam current emission test (PLS-II 전자총 진공이원화와 빔 전류 인출시험)

  • Son, Yoon-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1580-1581
    • /
    • 2011
  • The linear accelerator of Pohang Accelerator Laboratory(PAL) will drive a top-up mode operation in PLS-II(Pohang Light Source-II). Due to this kind of the operation mode, the electron gun is expected to have shorter life time of the cathode. Further in the PLS-II, two gate valves will be installed in front of the electron gun. The distance between the pre-bunching section and the electron gun will increase by 400 mm compared to the existing system due to the insertion of these gate valves. As a result the incident electron beam. One of the goals to improve the beam pulse width is by incorporating suitable biased voltage. In this paper, we will present test results of beam pulse width as a function of different biased voltage and focusing solenoid coil.

  • PDF

Experimental Verification of Transverse Electric Mode Controlled Vacuum Chamber of PLS-II Storage Ring

  • Ju, Yeong-Do;Ha, Tae-Gyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.229-229
    • /
    • 2012
  • It is significant issue to control the unwanted transverse electric (TE) modes in the vacuum chamber for preventing the position reading noise from the beam position monitor (BPM) of storage ring. We introduce shunt structure to control the frequency distribution of TE resonance modes excited in the vacuum chambers of the Pohang Light Source II (PLS-II). The design of shunt structure is performed using the full three dimensional finite-difference time-domain (FDTD) simulation. It is verified that the sympton of the BPM noise is not oberved up to the beam current of 190 mA in the commmissioning of PLS-II.

  • PDF

Design of shunt structure to avoide TE mode in PLS-II storage ring vacuum chamber

  • Ju, Yeong-Do;Ha, Tae-Gyun;Park, Seong-Ju;Park, Jong-Do
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.42-42
    • /
    • 2010
  • We, previously, proved that the noise in the vertical readback from some of beam position monitors (BPMs) in the vacuum chamber of Pohang Light Source (PLS) are caused by the transverse electric (TE) longitudinal harmonic resonances. Based on this analysis, we now design the shunt structure to remove the TE mode resonces near the BPMs operation frequency of 500 MHz in the storage ring vacuum chamber of PLS upgrade project (PLS-II). The simulation result and experimental test result will be presented.

  • PDF

The Status and prospect of Pohang Synchrotron Light Source at PAL on its 25th Anniversary

  • Jo, Mu-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.61.2-61.2
    • /
    • 2013
  • 우리나라 최초의 거대과학 장치인 포항방사광가속기(PLS)는 지난 16년(1994~2010) 동안 국내외 이용자에게 제3세대 방사광을 제공했다. 최초 2기의 빔라인을 시작으로 꾸준하게 빔라인 증설과 성능개선을 위해 노력해 왔다. 지속해서 늘어나는 방사광 이용자 수와 더욱더 좋은 수준의 방사광 요구에 부응하기 위하여 2009년부터 3년 동안 가속장치의 성능향상사업(PLS-II)을 마쳤다. PLS-II는 PLS 대비에너지와 빔전류는 3 GeV, 400 mA로 늘리는 반면 빔의 크기는 크게 줄이고 빔안정성을 개선한 고품질 X-선 방사광 발생장치이다. 2012년부터 16기의 삽입장치 빔라인을 포함한 30기의 빔라인을 가동하여 이용자 지원을 하고 있으며 초전도케비티 설치를 포함한 목표 성능의 확보에도 많은 노력을 기울이고 있다. 현재는 6 nm-rad의 빔에 미턴스, 3-GeV전자빔, 약 0.5 ${\mu}m-rms$ 빔안정도를 가진 200 mA Top-up 운전으로 빔을 제공 하고 있으며 2014년 말에는 저장전류 400 mA급의 PLS-II 목표치로 운전할 계획이다. 본 발표에서는 포항가속기의 25년 역사를 돌아보고 가속장치의 건설에 얽힌 이야기, 중요장치 그리고 운전과 빔제공에 관한 내용, 특히 핵심 운전가치인 빔안정성을 개선하고 유지하기 위한 노력을 빔운전 측면과 진공을 포함한 엔지지어링 측면에서 언급하고자 한다. PLS 건설부터 현재 운용 중인 30기의 빔라인에서 수행된 연구 성과의 통계에 대하여 훑어보고 X-선 산란과 광전자분광을 이용한 구조, 성분 및 물성분석, 그리고 이미징 등의 분야에서 나온 탁월한 연구 결과를 살펴본다. 앞으로 건설될 신규 빔라인과 빔라인의 향후 운영 방향을 소개한다. 마지막으로 지금 포항가속기연구소에서 건설 중인 제4세대 가속기(X-선 자유전자레이저) 프로젝트의 개요 및 건설 현황과 함께 앞으로 기대되는 새로운 과학에 대하여도 소개하고자 한다.

  • PDF

PLS 2GeV Linac Vacuum System(II) (PLS 2GeV 선형가속기 진공계통(II))

  • 박주식;김임경;오형석;남궁원
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.3
    • /
    • pp.282-287
    • /
    • 1993
  • PLS 2GeV 선형가속기 진공계는 K6 가속단위까지 성공적으로 조립, 설치되어 있다. K3 가속단위까지는 이미 E3712형 클라이스트론에서 공급되는 70MW 극초단파 전력으로 진공계 길들이기 과정을 완료하였다. 약 50MW의 극초단파 전력을 인가한 상태에서, 현재 진공도는 L-형 가속관 중심에서 6.2$\times$10-8torr, 클라이스트론 출력창에서 7.3$\times$10-9torr를 각각 유지하고 있으며, 최종 도달압력은 점차적으로 향상되고 있는 중이다. 본 논문에서는 PLS 2 GeV 선형가속기 진공계에 대한 전기회로적 변환에 의한 모델링과 해석, 그리고 가속기 전반부에 관한 초기 성능 검증결과를 논의하고자 한다.

  • PDF

Magnetic field imperfections of in-vacuum undulator on PLS-II beam dynamics

  • Chunjarean, Somjai;Hwan, Shin-Seung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.359-359
    • /
    • 2011
  • Many research applications in basic sciences and biology such as protein crystallography require hard x-rays in the range of 3-20 keV with high brightness. A medium energy storage ring as PLS-II with a beam energy of 3 GeV can meet such high photon energies. In-vacuum undulators (IVU) with a period length of 20 mm and a peak field of 0.97 T are used in the PLS-II ring to produce such X-rays in the fundamental or higher harmonics. Due to the many poles and high fields, insertion devices like wigglers and undulators have a significant impact on the stability of the electron beam with potential degradation of beam quality and life time. Therefore, nonlinear fields must be determined by measurement and evaluated as to their impact on beam stability. Specifically, transverse field roll-off can be a serious detriment to injection in top-up mode and must be corrected. We use magnetic field measurement data to evaluated beam stability by tracking particles using an explicit symplectic integrator in both, transverse and longitudinal planes.

  • PDF