• Title/Summary/Keyword: PLIF

Search Result 127, Processing Time 0.028 seconds

An Experimental Study on the Flame Structure of Partially Premixed Flame using OH PLIF (OH PLIF를 이용한 부분 예혼합 화염의 화염구조에 관한 실험적 연구)

  • Lee, Seung-Young;Lee, Jong-Ho;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.54-59
    • /
    • 2001
  • OH radical concentration have been measured in a methane-air partially premixed flames using PLIF. Excitation lines were selected $Q_{1}(6)$ branch, (1,0) band. The system is consisted of Nd:YAG laser, dye laser and frequency doubler to make pump beam for OH radical. On the direct photographs, flame height increases as fuel flow rate and equivalence ratio increase. And on the PLIF images, OH radical is distributed from premixed flame front to nonpremixed flame front through the flame structure with all equivalence ratio. OH overall concentrations increase with equivalence ratio. At the stoichiometric equivalence ratio, the peak of OH radical concentration exists strongly near the inner cone. As equivalence ratio is changed to richer, OH radical distribution goes thinly and the peak is increased as longitudinal direction. As the flow goes to the downstream, OH radical concentration decreases and broadens, because OH radical reacts with another species after OH formation at the initial oxidization. This phenomenon resembles radial distribution. At the l00cc fuel flowrate, the radial peak of OH radical exists from x/R=l.0 to 1.5.

  • PDF

Planar Laser-Induced Fluorescence (PLIF) Measurements of a Pulsed Electrothermal Plasma Jet

  • Kim, Jong-Uk;Kim, Youn J.;Byungyou Hong
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1808-1815
    • /
    • 2001
  • The characteristics of a pulsed plasma jet originating from an electrothermal capillary discharge have been investigate using laser-induced fluorescence (LIF) measurement. Previous emission measurements of a 3.1 kJ plasma jet show trial upstream of the Mach disk the temperature and electron number density are about 14,000 K and and 10$\^$17/ cm$\^$-3/, while downstream of the Mach dick tole values are about 25,000 K and 10$\^$18/ cm$\^$-3/, respectively. However, these values are barred on line-of-sight integrated measurements that may be misleading. Hence, LIF is being used to provide both spatially and temporally resolved measurements. Our recent work has been directed at using planar laser-induced fluorescence (PLIF) imaging of atomic copper in the plasma jet flow field. Copper is a good candidate for PLIF studies because it is present throughout the plasma and has electronic transitions that provide an excellent pump-detect strategy. Our PLIF results to date show that emission measurements may give a misleading picture of the flow field, as there appeals to be a large amount of relatively low temperature copper outside the barrel shock. which may lead to errors in temperature inferred from emission spectroscopy. In this paper, the copper LIF image is presented and at the moment, relative density of atomic copper, which is distributed in the upstream of the pulsed plasma jet, is discussed qualitatively.

  • PDF

Analysis of the Spray Distribution Characterization of Impinging Jet Injectors for Liquid Rockets Using PLIF Technique (PLIF 기법을 이용한 액체로켓용 충돌분사 인젝터의 분무분포 특성 해석)

  • 정기훈;윤영빈;황상순
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.1
    • /
    • pp.36-45
    • /
    • 2000
  • Most researches for impinging jet spray have been focused on under-standing the breakup mechanism of a liquid sheet formed by the collision of jets and modeling the spray breakup using experimental data. For this reason, there have been few studies on the characteristics of the spatial spray distribution which affects significantly the combustion efficiency. Hence, we measured the radial distribution of fuel massflux using a like-doublet type injector. Instead of PDPA(Phase Doppler Particle Analyzer) which has been used only for the point measurement of the drop size of spray, PLIF(Planar Laser Induced Fluorescence) technique was developed lot the 2-D measurement of the massflux distribution of spray Indirect photography technique was also used to verify PLIF data.

  • PDF

Structure of Turbulent Premixed Opposed Impinging Jet Flame with Simultaneous PIV/OH PLIF Measurements (PIV/OH PLIF 동시측정을 이용한 난류 대향 분출 예혼합화염 구조 연구)

  • Cho, Yong-Jin;Kim, Ji-Ho;Cho, Tae-Young;Yoon, Young-Bin
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.1
    • /
    • pp.36-45
    • /
    • 2003
  • The subject of turbulent premixed flames has been focused by many researchers for a number of decades. Especially, Borghi suggested a magnificent diagram classifying turbulent combustion areas and Lipatnikov and Chomiak modified this diagram. Recently, experimental techniques have been developed so that we can use PIV for measuring 2D velocity field and apply OH PLIF techniques for obtaining flame locations. In present study, a new diagram is proposed using strain rates and OH signal intensity. Thus, simultaneous PIV and OH PLIF measurements are used for shear strain rates and flame locations, respectively. It is believed that the shear strain rates represent flow characteristics such as turbulence intensity and the OH intensity indicates the flame characteristics such as burning velocities.

  • PDF

LIF/PLIF Measurements of OH Concentration in Flames (LIF/PLIF를 이용한 화염에서의 OH농도 측정)

  • 이원남
    • Journal of the KSME
    • /
    • v.33 no.12
    • /
    • pp.1031-1042
    • /
    • 1993
  • 연소현상에 대한 이해를 증가시키기 위하여 화염을 이용한 많은 실험적 연구가 이루어져 왔다. 특히 연소 모델의 개선과 증명을 위하여는 화염에서의 성분 농도 측정이 필수적이며, 최근에 들어 측정 가능해진 래디컬성분의 측정은 연소해석분야에 많은 진전을 가져왔다. OH, H 및 O는 연료의 분해 (decomposition) 및 연소 산화물생성 이외에도 CO와 NO 같은 공해물질의 형성등 연소과정에서 매우 중요한 래디컬들이며, 특히 화염영역에서의 OH의 전파(transport)는 화염의 점화 및 안정성 (stability)에도 큰 영향을 미친다. OH래디컬은 연소과정에서 가장 중요한 성분 중 하나이며, 또한 스펙트럼이 비교적 잘 알려져 있어 레이저 유도 형광의 적용이 용이하므로 화염에서의 OH농도 측정에 LIF(laser induced fluorescence) 또는 PLIF(planar laser induced fluorescence)가 널리 사용되고 있다. 따라서 LIF 및 PLIF의 원리 및 연소분야에서의 응용을 OH농도 측정을 중심으로 소개하고자 한다.

  • PDF

Simultaneous PIV/OH PLIF Measurements in Hydrogen Nonpremixed Flames with Coaxial Air (PIV/OH PLIF 동시 측정을 이용한 동축공기 수소확산화염의 실험적 연구)

  • Kim, Mun-Ki;Kim, Seung-Han;Yoon, Young-Bin
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.115-123
    • /
    • 2003
  • Simultaneous measurements of velocity and OH distribution were made using particle image velocimetry(PIV) and planar laser-induced fluorescence(PLIF) of OH radical in turbulent hydrogen nonpremixed flames with coaxial air. The OH radical was used as an approximate indicator of chemical reaction zone. The OH layer was correlated well with the stoichiometric velocity, $U_s$, instantaneously and on average. In addition, high strain-rate regions almost coincide with the OH distribution. The residence time in flame surface, calculated from the root-mean-square value of the radial velocity, is proportional to $(x/d_F)^{0.7}$. It is found that the mean value of principal strain rate on the OH layer can be scaled with $(x/d_F)^{-0.7}$ and therefore, the product of the residence time and the mean strain rate remains constant over all axial positions.

  • PDF

Posterior Lumbar Interbody Fusion Versus 360° Fixation in Degenerative Lumbar Diseases (퇴행성 요추 질환에서 후방경유 추체간 유합술과 360° 고정술의 비교)

  • Lee, Nok Young;Oh, Seong Hoon;Rhee, Woo Tack;Bae, Jae Seong;Yi, Hyeong Joong;Kim, Young Soo;Ko, Yong;Kim, Kwang Myung;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1193-1199
    • /
    • 2001
  • Objectives : The goal of operation for degenerative lumbar diseases is to relieve radiculopathy and low back pain and to prevent further degeneration. The authors analyzed the surgical results of posterior lumbar interbody fusion(PLIF) and $0^{\circ}$ fixation to evaluate the proper treatment policy in spinal stenosis, degenerative spondylolisthesis and low grade isthmic spondylolisthesis. Material and Methods : The authors performed PLIF on 92 patients and $0^{\circ}$ fixation on 138 patients with spinal stenosis, degenerative spondylolisthesis and low grade isthmic spondylolisthesis. We retrospectively studied clinical outcomes and subjective satisfaction of these patients by several criteria such as visual analog scale(VAS), Prolo's economic and functional outcome scale, medication usage after operation and questionaire for overall outcome. Result : Pre- and postoperative VAS on back pain and leg pain showed decrease of pain from 6.5, 6.7 to 2.2, 2.4 in PLIF group and from 7.0, 7.2 to 2.5, 2.7 in $0^{\circ}$ fixation group. Excellent and good outcomes on Prolo's scale were 81.5% in PLIF group and 82.6% in $0^{\circ}$ fixation group. Medication usage after operation was reduced in 79.3% of PLIF group and in 78.3% of $0^{\circ}$ fixation group. Patients' self-reported overall success of their procedure showed 82% in PLIF group and 84% in $0^{\circ}$ fixation group. Conclusion : Both PLIF and $0^{\circ}$ fixation showed good outcomes and provided biomechanically stable fusion in spinal stenosis, degenerative spondylolisthesis and low grade isthmic spondylolisthesis. Therefore, only PLIF seems necessary and considered a proper surgical treatment for these disorders.

  • PDF

Preheated Air Combustion Characteristics of Partially Premixed Flame (부분 예혼합 화염의 예열공기 연소특성)

  • Lee, Seung-Young;Lee, Jong-Ho;Jeon, Chung-Hwan;Chang, Young-June
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.65-70
    • /
    • 2001
  • OH radical and NOx have been measured in a methane-air partially premixed flame using PLIF technique to define preheated air combustion characteristics. The temperature of mixture is determined by 300K, 400K, 600K and 800K below the auto-ignition temperature respectively. Flame height increases as equivalence ratio increased. As initial enthalpy is supplied, the radius of flame was increased and much amount of yellow flame in rich equivalence ratio was observed. This is due to the faster burning velocity. Also initial oxidization begins earlier as the initial temperature of mixture increased. It means that height of premixed flame front decreased. This phenomenon can be observed OH PLIF image. The qualitative analysis of OH concentration in the PLIF image shows that overall OH concentration increases with equivalence ratio and the initial temperature of mixture increased. At the preheating temperature goes up, axial gradient of OH concentration is less steep than that of lower temperature condition. This may identify that combustion reacts continuously, so preheated air combustion can evade the local heating and make high temperature indiscriminately in the overall reaction zone.

  • PDF

A Study of Combustion Instability Mode in Dual Swirl Gas Turbine Combustor by PLIF and Chemiluminescence Measurement (PLIF 및 자발광 계측을 이용한 이중선회 가스터빈 연소기에서 연소불안정 모드 연구)

  • Choi, Inchan;Lee, Keeman;Juddoo, Mrinal;Masri, A.R.
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.1
    • /
    • pp.29-38
    • /
    • 2014
  • This paper described an experimental investigations of combustion instability mode in a lean premixed dual swirl combustor for micro-gasturbine system. When such the instability occurs, a strong coupling between pressure oscillations and unsteady heat release excites a self-sustained acoustic wave which results in a loud, annoyed sound and may also lead a structural damage to the combustion chamber. The detailed period of flame behavior and heat release in combustion instability mode have been examined with high speed OH and CH-PLIF system and $CH^*$ chemiluminescence measurement, flame tomography with operated at 10 kHz and 6 kHz each. Experiment results suggest that unstable flame behavior has a specific frequency with 200 Hz and this frequency is accords with about 1/2 sub-harmonic of combustor resonance frequency, not fundamental frequency. This is very interesting phenomenon that have not reported yet from other previous works. Therefore, when a thermo-acoustic instability with Rayleigh criterion occurs, the fact that the period of heat release and flame behavior are different each other was proposed for the first time through this work.