• Title/Summary/Keyword: PLC communication

Search Result 441, Processing Time 0.029 seconds

Development of Sensor and Signal Duplicator for Building Automation (빌딩 자동제어용 센서 및 신호의 듀플리케이터(Duplicator) 개발)

  • Jang, Kyeong-Uk;Lee, Yong-Min;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.184-187
    • /
    • 2016
  • In this paper, we propose the sensor and the signal duplicator for the automatic building control. Developed duplicator realizes the sensor data collection apparatus and mimics the measured data and, thus, reduces the construction cost by using logical communication layer. Furthermore, the system supports the open protocols and can be associated with HMI(Human Machine Interface) used on the market. Developed duplicator is proved to be functional within the real environment. Measurement error rate, operating temperature, and operating humidity show very good results by the certified testing apparatus and organization.

A Study on the Fault Tolerant System for the Optimum Performance of Virtual Sensor (가상센서를 활용한 고장 허용 시스템에 관한 연구)

  • Song, Min-Woo;Choi, Won-Seok;Lee, Doo-Wan;Jang, Kyung-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.7
    • /
    • pp.1634-1640
    • /
    • 2010
  • In this paper, I studied the "Establishment of Fault Tolerant System" as well as the sensor and cylinder that are general components being used in automation equipments. I design a system that when the sensor breaks down on free flow conveyor, it will be converted to virtual sensor system mode by simulation, also I design IPC(Internal Pressure Cylinder), a basis of various applicable fault tolerant system by analyzing the changing of analog data according to the load of operation. With IPC and the increasing ability of developer, the Fault Tolerant System will be widely applied in the increasment of service time of cylinder, grease pouring time expection, fault recognition of cylinder and etc.

Verification of The Variable-Speed Wind Turbine Control System by Using the Simulator (시뮬레이터를 이용한 가변속 풍력발전기 제어시스템 검증)

  • Cha, Sam-Gon;Han, Sang-Yul;Cha, Jong-Hwan;Choi, Won-Ho;Lee, Seung-Kuh
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.370-373
    • /
    • 2007
  • For the development of wind turbine, generally simulator is used. Simulator include wind turbine components. e.g blades, pitch and pitching method, rotor, yaw system, tower, drive train and so on. Few the more, it include a external circumstance. e.g wind speed, wind direction, air density. these basic parameters be used for the control of wind turbine by wind turbine controller in wind turbine simulator. The wind turbine controller can be designed in the wind turbine simulator. But a developer must make the real control system that will be made using PLC or PC or other processor. The developer must verify the function of control system. that is control algorithm , I/O function, communication, sequence and so on. This verification is possible if we substitute the real wind turbine control system for wind turbine controller in the simulator.

  • PDF

A Centralized Monitoring System for Factory Electrical Installation Using Active Database (능동 데이터베이스를 이용한 중앙전력감시시스템)

  • Choi, Sang-Yule;Moon, Hyun-Ho;Lee, Jong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.115-122
    • /
    • 2010
  • The main purpose of centralized monitoring system is to manage factory electrical installation efficiently by on-line data acquisition and supervisory control. The existing centralized system is only able to be managed by operator whenever electrical installation's faults are detected. Therefore, it may be possible for propagating the installation's faults when operator make the unexpected mistakes. To overcome the unexpected mistakes, in this paper, the author presents a centralized monitoring system for factory electrical installation using active database. by using active database production rule, stated system can minimize unexpected mistake and can operate centralized monitoring system efficiently. Test results on the five factory electrical installations show that performance is efficient and robust.

Intelligent Home Energy Management based on Powerline Communication (전력선통신을 이용한 지능형 홈에너지 관리시스템)

  • Ju, Seong-Ho;Choi, Moon-Seok;Choi, Jong-Hyup;Lim, Yong-Hoon;Kim, Tae-Kyung
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.148-150
    • /
    • 2008
  • 지구온난화와 화석연료의 고갈 등 에너지관련 문제들이 발생함에 따라 제한된 자원의 효율적인 소비가 중요한 연구주제로 다루어지고 있다. 특히 자원수입국인 우리나라의 경우는 국제 유가 급등과 같은 에너지파동에 상당히 민감하기 때문에 에너지 관리를 통한 정확한 수급정책 수립 및 효율적인 소비생활이 무엇보다 중요하다. 이를 위해 우선적으로 취할 수 있는 해결책 중의 하나가 댁내 가전기기의 불필요한 전력낭비를 최소화하는 것이다. 이번 연구에서는 전력선통신(PLC)기반 원격검침 인프라를 활용하여 1차적으로 가전기기의 대기전력을 지능적으로 관리함으로써 전력낭비를 최소화하고 2차적으로 전력소비모니터링 서비스를 제공함으로써 사용자가 능동적으로 전력소비를 줄일 수 있도록 하는 지능형 홈에너지 관리시스템을 개발하였으며, 실제 수용가를 대상으로 구축, 운영함으로써 향후 에너지를 효율적으로 관리할 수 있는 방안을 제시하고자 한다.

  • PDF

A Study on the High Frequency Model of Pole-transformers (주상 변압기의 고주파 모델에 관한 연구)

  • Han, Byung-Duk;Oh, Jung-Hwan;Lim, Tae-Hoon;Kim, Hyun-Jong;Lim, Choon-Baek;Kim, Han-Soo;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.464-466
    • /
    • 2000
  • In this paper, the high frequency models of pole-transformers are provided to confirm the feasibility of PLC systems between high and low voltage distribution systems. The impedance of transformers is measured to verify the characteristics of transformers at high frequency from 100[kHz] to 1[MHz] and the equivalent circuits of the transformers were designed based on the measured impedance. The signals transmitted from the primary and the secondary sides of the transformers were measured, respectively. The transmission loss of the transformers was obtained by the measured signals. Numerical analysis using the equivalent circuit is compared to the measured signals. The possibility of communication through pole-transformers is presented by experiments and simulations.

  • PDF

Signal Transmission Properties of the Inductive Coupler for PLC (전력선통신용 비접촉식 커플러의 신호전송 특성 향상 연구)

  • Kim, Hyun-Sik;Kim, Jong-Ryung;Huh, Jeong-Sub;Lee, Hae-Yeon;Lee, Jun-Hui;Jung, Won-Chae;Oh, Young-Woo;Byun, Woo-Bong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.239-240
    • /
    • 2006
  • 저손실 고투자율 특성을 가지는 ${\alpha}-Fe$ 나노결정 자심재료를 제조하기 위한 열처리 온도 변화에서, $510^{\circ}C$의 열처리 조건에서 가장 높은 투자율과 신호전송 특성을 나타내었다. 저주파 대역에서의 신호 전송 특성은 자심재료의 자기적 특성에 지배적인 영항을 받으며, 고주파 대역의 신호전송 특성은 임피던스 매칭으로 향상시킬 수 있었다. 그리고 커플러의 출력부에 신호증폭장치를 삽입하여 자기유도에 의해 신호가 커플링될 때 발생하는 삽입손실을 보완하여 커플러의 특성을 향상시킬 수 있었다.

  • PDF

A Study on the Characteristic of P. I. D Control with M. L. P Communication in GSIKGL (GSIKGL M. L. P 통신에 의한 P. I. D 제어 특성에 관한 연구)

  • Wee, Sung-Dong;Oh, Soo-Hong;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.91-100
    • /
    • 2000
  • An operating principle of PID module was implemented using the load, where the integer in a PID measuring derivate equation were valid in the ranges of 500-9000, 60-1000, and 000-9000, for P, I and D, respectively. A load operation program was designed to investigate the PID theory and its realization process. With it, it was examined the process that the current PV tracts the target SV, By investigating the time when the PV approaches the SV and the rate at which the EV is varied, it is revealed that 1) larger (or Smaller) Kp leads to faster (or slower) approaching of PV to SV, 2) smaller (or larger) Ti results in faster (or slower) approaching of PV to SV, 3) larger (or smaller)$T_d$ causes smaller (or Larger) rate variation in the EV. These observation were found to coincide with those of PID operating characteristics. Though this implementation, it is known for the widespread use of PID module that an improvement should be made in the error of temperature. This, meanwhile, implies that the computational time of conventional manipulation valve must be faster than 0.1 second. It is demanded that an improved PID module including the A/D and D/A module, in itself must be used in conjunction with PLC.

  • PDF

A Study on Implementation of Powerline Carrier Modem using 5-ary Frequency Shift Keying Method (5-ary 주파수 천이 키잉 방식을 이용한 전력선 캐리어 모뎀 구현에 관한 연구)

  • Park, Sung-Wook;Park, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.39-44
    • /
    • 2005
  • In this paper, we use the 5-ary frequency shift keying method for robust powerline communication. To transmit the data by the 3-ary carrires among 5-ary carrirers and three carriers are 115kHz, 120kHz and 125kHz. Each time of three carrires is 0.33ms and total transmitting time duration from zero crossing point has 1ms. We use the dummy carriers which are 50kHz and 350kHz for monitoring the powerline channel state, dummy signal duration is received during 1ms. Experimentation result is shown that the implemented PLC transceiver has better than chirp transceiver at the capacitive load testing in spite of low transmission power.

A design of MASBM (Multi-Agent Service Bundle Manager) architecture for Smart Space Middleware (Smart Space Middleware를 위한 MASBM (Multi-Agent Service Bundle Manager) 구조 설계)

  • Son, Min-Woo;Shim, Ghi-Taek;Lee, Ju-Yeon;Shin, Dong-Il;Shin, Dong-Kyoo
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11b
    • /
    • pp.625-627
    • /
    • 2005
  • 사용자가 시간과 장소에 구애 받지 않고 컴퓨터를 자연스럽고 효율성 있게 사용할 수 있는 환경을 의미하는 유비쿼터스 컴퓨팅은 네트워크와 센서(Sensor), smart devices, 무선 통신과 smart middleware(UPnP(Universal Plug and Play), Jini, HAVi(Home Audio Video Interoperability) IEEE 1394, PLC (Power Line Communication) 등) 등을 기반으로 Smart Space를 만들 수 있다. 그러나 여러 종류의 가전제품들이 늘어나고 수많은 사용자들의 요구를 충족시키기엔 smart middleware의 단일 제어로는 처리가 불가능하여 본 논문에서는 이기종간의 미들웨어간의 상호작용을 위해 개발된 OSGi(Open Service Gateway Initiative) Spec. 3에서 제공하는 서비스 플랫폼(Service Platform)을 기반으로 사용자/디바이스 관리 및 분산 시스템 등의 취약점들을 보완하여 Smart Space상에서 효율적인 서비스 번들을 관리하기 위해 MASBM(Multi-Agent Service Bundle Manager)을 제안하였다.

  • PDF