• Title/Summary/Keyword: PLC

Search Result 1,484, Processing Time 0.039 seconds

SOS-Net for Generattion of PLC Program (PLC 프로그램 생성을 위한 SOS-Net)

  • Ko, Min-Suk;Hong, Sang-Hyun;Wang, Gi-Nam;Park, Sang-Cheul
    • Korean Journal of Computational Design and Engineering
    • /
    • v.14 no.1
    • /
    • pp.60-68
    • /
    • 2009
  • Because of the reduced product life-cycle, industries are making an effort to bring down the process planning time. In the traditional approach, we have to analyze established process planning, then design the time chart based on process information and drawing the formal time chart such as SOP(sequence of operation). Thereafter, it will be converted to PLC code that is a time consuming and redundant job. Similarly, Industrial automated process uses PLC Code to control the factory; however, control information and control code(PLC code) are difficult to understand. Hence, industries prefer writing new control code instead of using the existing one. It shows the lack of information reusability in the existing process planning. As a result, to reduce this redundancy and lack of reusability, we propose SOS-Net modeling method. Unlike past stabilized process planning that is rigid to any change; our proposed SOS-Net modeling method is more adaptable to the new changes. The SOS-Net model is easy to understand and easy to convert into PLC Code accordingly. Therefore, we can easily modify the control information and reuse it for new process planning. The proposed model plays an intermediary role between process planning and PLC code generation. It can reduce the process planning and implementation time as well as cost.

Ultra-Power-Saving 2 Ports PLC Wall Switch Development (초절전형 PLC 2구 스위치 개발)

  • Han, Jae-Yong;Lee, Sun-Heum
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.51-55
    • /
    • 2007
  • Generally, PLC (Power Line Communication) based home automation devices such as wall switch, walt socket, gas controller, etc, must maintain wake-up status at all time to control other electronic devices and monitor their on/off status whether they are in service or not. In order to reduce the unnecessary energy consumption during the standby mode, the new power-saving PLC 2 ports wall switch has been developed, separating PLC communication part and controller part and introducing sleep mode. In addition, to expand life cycle of PLC product and to reduce the rate of product failure in active mode, the instant controlling method in controlling process is adopted instead of the maintenance controlling method. In comparison to the earlier model, the new 2 ports PLC wall switch has reduced power by 0.95[W] less in standby mode and 3.2[W] less in active mode than the previous one.

PLC Devices Fabricated on Flexible Plastic Substrate by Roll-to-Roll Imprint Lithography (유연 기판을 이용한 PLC소자 제작을 위한 롤투롤 공정 연구)

  • Kang, Ho Ju;Kim, Taehoon;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.4
    • /
    • pp.25-29
    • /
    • 2015
  • Demand for a low-cost, high-throughput, and high-resolution patterning method for fabricating devices continues to increase. The roll-to-roll (R2R) imprint lithography technique has received a great deal of attention as a means of fabricating next-generation devices. In this paper, we propose a fabrication method for polymeric planar lightwave circuit (PLC) devices that uses R2R imprint lithography. The proposed technique uses an elastomeric polydimethylsiloxane (PDMS) mold. A Si wafer with micro patterns is used as the Si master. The PDMS mold is then replicated from the Si master. By applying a precise web tension and at a given web speed, we fabricated a micro-patterned PLC device. The insertion losses were 4.0 dB for a $1{\times}2$ optical splitter. As such, the proposed method of fabricating a PLC device by the R2R process was shown to be an effective solution.

Development of an Intelligent Software Programmable Logic Controller for IEC1131-3 International Standard Languages (IEC1131-3 표준언어 처리를 위한 지능적 소프트웨어 PLC 개발)

  • Cho, Young-Im
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.2
    • /
    • pp.207-215
    • /
    • 2004
  • The PLC programming by IEC1131-3 is hard to handle to ordinary users as well as professionals. Also it has not a generality, so that it couldn't be debugging some logic errors easily. In order to be adapted for such environment, In this paper, I have developed the ISPLC(Intelligent Agent System based Software Programmable Logic Controller). In ISPLC system, LD programmed by a user is converted to the C code which can be used in a commercial editor such as Visual C++. The detection of logical errors in C code is more effective than PLC programming itself. ISPLC provides the GUI-based interface in web environment and an easy programming platform to such beginners as well as professionals. The study of code conversion of LD to IL as well as IL to C is firstly tried in the world as well as KOREA. To show the effectiveness of the developed system, I applied it to a practical case, a real time traffic control system. ISPLC is minimized the error debugging and programming time owing to be supported by windows application programs.

Heat Shock Protein $90{\beta}$ Inhibits Phospholipase $C{\gamma}-1$ Activity in vitro

  • Cho, Sang-Min;Kim, Sung-Kuk;Chang, Jong-Soo
    • Biomedical Science Letters
    • /
    • v.12 no.4
    • /
    • pp.419-425
    • /
    • 2006
  • Phospholipase $C-{\gamma}1\;(PLC-{\gamma}1)$ is an important signaling molecule for cell proliferation and differentiation. $PLC-{\gamma}1$ contains two pleckstrin homology (PH) domains, which are responsible for protein-protein interaction and protein-lipid interaction. $PLC-{\gamma}1$ also has two Src homology (SH)2 domains and a SH3 domain, which are responsible for protein- protein interaction. To identity proteins that specifically binds to PH domain of $PLC-{\gamma}1$, we prepared and incubated the glutathione S-transferase(GST)-fused PH domains of $PLC-{\gamma}1$ with COS7 cell lysate. We found that 90 kDa protein specifically binds to PH domain of $PLC-{\gamma}1$. By matrix-assisted laser desorption ionization time of flight-mass spectrometry, the 90 kDa protein revealed to be heat shock protein (Hsp) $90{\beta}$. Hsp $90{\beta}$ is a molecular chaperone that stabilizes and facilitates the folding of proteins that are involved in cell signaling, including receptors for steroids hormones and a variety of protein kinases. To know whether Hsp $90{\beta}$ affects on $PLC-{\gamma}1$ activity, we performed $PIP_2$ hydrolyzing activity of $PLC-{\gamma}1$ in the presence of purified Hsp $90{\beta}$ in vitro. Our results show that the Hsp $90{\beta}$ dose-dependently inhibits the enzymatic activity of $PLC-{\gamma}1$ and further suggest that Hsp $90{\beta}$ regulates cell growth and differentiation via regulation of $PLC-{\gamma}1$ activity.

  • PDF

A Case Study for Estimating the Defect Rate of PLC Using Sampling Inspection and Improving the Cause of Defects (샘플링검사를 이용한 PLC의 불량률 추정 및 불량원인 개선 사례연구)

  • Moon, In-Sun;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.44 no.4
    • /
    • pp.128-135
    • /
    • 2021
  • WDM(Wavelength Division Multiplexing) is called a wavelength division multiplexing optical transmission method and is a next-generation optical transmission technology. Case company F has recently developed and sold PLC(Planar Lightwave Circuit), a key element necessary for WDM system production. Although Chinese processing companies are being used as a global outsourcing strategy to increase price competitiveness by lowering manufacturing unit prices, the average defect rate of products manufactured by Chinese processing companies is more than 50%, causing many problems. However, Chinese processing companies are trying to avoid responsibility, saying that the cause of the defect is the defective PLC Wafer provided by Company F. Therefore, in this study, the responsibility of the PLC defect is clearly identified through estimating the defect rate of PLC using the sampling inspection method, and the improvement plan for each cause of the PLC defect for PLC yeild improvement is proposed. The result of this research will greatly contribute to eliminating the controversy over providing the cause of defects between global outsourcing companies and the head office. In addition, it is expected to form a partnership with Company F and a Chinese processing company, which will serve as a cornerstone for successful global outsourcing. In the future, it is necessary to increase the reliability of the PLC yield calculation by extracting more precisely the number of defects.

Increased Expression of Phospholipase C-$\gamma1$ Activator Protein, AHNAK in Human Lung Cancer Tissues (인체 폐암조직에서 Phospholipase C-$\gamma1$의 활성화 단백, AHNAK의 발현양상)

  • Oh, Yoon-Jung;Park, Chun-Seong;Choi, So-Yeon;Cheong, Seong-Cheoll;Lee, Sun-Min;Hwang, Sung-Chul;Lee, Yi-Hyeong;Hahn, Myung-Ho;Lee, Kyi-Beom;Ryu, Han-Young;Ha, Mahn-Joon;Bae, Yoon-Su;Rhee, Seo-Goo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.347-355
    • /
    • 1999
  • Background: Phospholipase C(PLC) plays a central role in cellular signal transduction and is important in cellular growth, differentiation and transformation. There are currently ten known mammalian isozymes of PLC reported to this date. Hydrolysis of phosphatidylinositol 4,5-bisphosphate($PIP_2$) by PLC produces two important second messengers, inositol 1,4,5-trisphosphate($IP_3$) and diacylglycerol. PLC-${\gamma}1$, previously, was known to be activated mainly through growth factor receptor tyrosine kinase. Other mechanisms of activating PLC-yl have been reported such as activation through tau protein in the presence of arachidonic acid in bovine brain and activation by $IP_3$, phosphatidic acid, etc. Very recently, another PLC-${\gamma}1$ activator protein such as tau has been found in bovine lung tissue, which now is considered to be AHNAK protein. But there has been no report concerning AHNAK and its associated disease to this date. In this study, we examined the expression of the PLC-${\gamma}1$ activator, AHNAK, in lung cancer specimens and their paired normal. Methods: From surgically resected human lung cancer tissues taken from twenty-eight patients and their paired normal counterparts, we evaluated expression level of AHNAK protein using immunoblot analysis of total tissue extract Immunohistochemical stain was performed with primary antibody against AHNAK protein. Results: Twenty-two among twenty-eight lung cancer tissues showed overexpression of AHNAK protein (eight of fourteen squamous cell lung cancers, all of fourteen adenocarcinomas). The resulting bands were multiple ranging from 70 to 200 kDa in molecular weight and each band was indistinct and formed a smear, reflecting mobility shift mainly due to proteolysis during extraction process. On immunohistochemistry, lung cancer tissues showed a very heavy, dense staining with anti-AHNAK protein antibody as compared to the surrounding normal lung tissue, coresponding well with the results of the western blot Conclusion: The overexpression of PLC-${\gamma}1$ activator protein, AHNAK in lung cancer may provide evidence that the AHNAK protein and PLC-${\gamma}1$ act in concerted manner in carcinogenesis.

  • PDF

Enhanced Expression of Phospholipase C-$\gamma$1 in Regenerating Murine Neuronal Cells by Pulsing Electromagnetic Field (흰쥐에서 편측 반회후두신경 재지배 후 Phopholipase C-$\gamma$1(PLC-$\gamma$1)의 발현과 후두기능회복과의 관계)

  • 정성민;신혜정;김성숙;김문정;윤선옥;박수경;신유리;김진경
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.12 no.2
    • /
    • pp.126-132
    • /
    • 2001
  • Background and Objectives : Signal traduction through phospholipase C(PLC) participate in the regulation of cell growth and differentiation. Growth factors bind to their receptors and thereby induce tyrosine phophorylation of the phospholipase C-${\gamma}$1(PLC-${\gamma}$1). PLC-${\gamma}$1 is a substrate for several receptor tyrosine kinases and its catalytic activity is increased by tyrosine phosphorylation. Tyrosine kinase phosphorylation of PLC-${\gamma}$1 stimulates PLC activation and cell proliferation. However the signal transduction pathway and the significance of PLC in injured recurrent laryngeal nerve regeneration is unknown. Therefore after we obtained fuctionally recovered rats using PEMF in this study, we attempt to provide some evidence that PLC plays a role in nerve regeneration itself and regeneration related to PEMF through the analysis of the difference between fucntional recovery group and non-recovery group in the recurrent laryngeal nerve. Materials and Method : Using 32 healthy male Sprague-Dawley rats, transections and primary anastomosis were performed on their left recurrent laryngeal nerves. Rats were then randomly assigned to 2 groups. The experimental group(n=16) received PEMS by placing them in custom cages equipped with Helm-holz coils(3hr/day, 5days/wk, for 12wk). The control group(n=16) were handled the same way as the experimental group, except that they did not receive PEMS. Laryngo-videoendoscopy was performed before and after surgery and followed up weekly. Laryngeal EMG was obtained in both PCA and TA muscles. Immunohistochemisty staining and Western blotting analysis using monoclonal antibody was performed to detect PLC-${\gamma}$1 in recurrent laryngeal nerve and nodose ganglion. Results : 10 rats(71%) in experimental group and 4 rats(38%) in the control group showed recovery of vocal fold motion. Functionally-recoverd rats show PLC-${\gamma}$1 positive cells in neuron and ganglion cells after 12 weeks from nerve injury. Conclusion : This study shows that PLC1-${\gamma}$ involved in singnal trasduction pathway in functinal recovery of injured recurrent laryngeal nerve and PEMF enhance the functional recovery by effect on this molecule.

  • PDF

Development of PLC modules for the safety verification of chemical processes (공정의 안전 검증을 위한 PLC 모듈 개발)

  • Jeong, Sang-Hun;Lee, Kwang-Soon;Moon, Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.1
    • /
    • pp.53-59
    • /
    • 1996
  • An automatic verification method has been studied to determine the safety and operability of programmable logic controller (PLC) based systems. For the systematic and efficient verification, we have developed a conversion method from relay ladder logic (RLL) to the verification system description. RLL is a common representation used to document PLC programs for the sequential logic of the system such as the safety interlocks and the startup/shutdown procedures. Once the modules are developed, complex RLLs can be represented by the combination of modules. As a result we can verify complex PLC systems using the verification method including RLL modules. The developed modules are used to verify alarm systems and show that the method is valid.

  • PDF

Test Driver Generation for Integration Test between Real-Time Operating System and PLC Application (실시간 운영체제와 PLC 어플리케이션의 통합 테스트를 위한 테스트 드라이버 생성 방안)

  • Jang, Jin-A;Sung, Ah-Young;Choi, Byoung-Ju
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10c
    • /
    • pp.448-452
    • /
    • 2006
  • PLC 프로세서 모듈의 시스템 태스크는 RTOS 커널 및 PLC 어플리케이션과 유기적으로 연관되어 있기 때문에 단독으로 테스트 할 수 없고, 어플리케이션을 테스트 드라이버로 활용해야 한다. 본 논문에서는 RTOS와 PLC 어플리케이션의 통합 테스트 단계에서, 시스템 태스크를 테스트 하기 위한 테스트 드라이버를 생성하는 방안을 기술하고, 이를 원자력 발전소의 PLC 프로세서 모듈에 적용한 실험 결과를 기술한다.

  • PDF