유한요소법을 이용한 피로하중을 받는 균열선단의 소성영역크기에 대한 연구 (A Study on Plastic Zone at the Crack Tip under Cyclic Loading by FEM)

  • 김경수;심천식;이재욱;조형민
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.151-154
    • /
    • 2002
  • In this paper, the effect of the crack growth length on the plastic zone size at the crack tip and the crack growth lives of the DENT specimen under constant amplitude cyclic loading were studied. The plastic zone size was calculated by nonlinear static method in commercial finite element analysis program, MSC/NASTRAN and the crack growth lives were also calculated by using compliance function considering geometric shape in MSC/FATIGUE. The calculated plastic zone size increased proportional to the crack length. And comparison of calculated plastic zone size and crack growth lives with the experimental results shows a good agreement.

  • PDF

The effect of micro pore on the characteristics of crack tip plastic zone in concrete

  • Haeri, Hadi;Sarfarazi, V.
    • Computers and Concrete
    • /
    • 제17권1호
    • /
    • pp.107-127
    • /
    • 2016
  • Concrete is a heterogeneous material containing many weaknesses such as micro-cracks, pores and grain boundaries. The crack growth mechanism and failure behavior of concrete structures depend on the plastic deformation created by these weaknesses. In this article the non-linear finite element method is used to analyze the effect of presence of micro pore near a crack tip on both of the characteristics of crack tip plastic zone (its shape and size) and crack growth properties (such as crack growth length and crack initiation angle) under pure shear loading. The FE Code Franc2D/L is used to carry out these objectives. The effects of the crack-pore configurations and the spacing between micro pore and pre-excising crack tip on the characteristics of crack tip plastic zone and crack growth properties is highlighted. Based on the obtained results, the relative distance between the crack tip and the micro pore affects in very significant way the shape and the size of the crack tip plastic zone. Furthermore, crack growth length and crack initiation angle are mostly influenced by size and shape of plastic zone ahead of crack tip. Also the effects of pore decrease on the crack tip by variation of pore situation from linear to perpendicular configuration. The critical position for a micro pore is in front of the crack tip.

A study on the measurement of plastic zone and crack growth length at the crack tip under cyclic loading using ESPI system

  • Kim, Kyung-Su;Kim, Ki-Sung;Shim, Chun-Sik
    • Structural Engineering and Mechanics
    • /
    • 제15권3호
    • /
    • pp.367-378
    • /
    • 2003
  • The magnitude of the plastic zone around the crack tip of DENT (Double Edge Notched Tension) specimen and the crack growth length under cyclic loading were measured by ESPI (Electronic Speckle Pattern Interferometry) system. The measured magnitude of plastic zone was compared with the proposed by Irwin and calculated by a nonlinear static method of MSC/NASTRAN. The measured crack growth length by ESPI system was also compared with the obtained data by the image analysis system. From the study, it is confirmed that the plastic zone and crack growth length can be measured accurately with the high-tech equipment (ESPI System).

탄소성 동적 균열전파의 만곡현상 (Dynamic elastic-plsstic Crack Curving Phenomenon)

  • 이억섭;정형진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.704-708
    • /
    • 1996
  • The elastic dynamic crack curving could be obtained by controlling the loading rate, the initial crack-tip blunting to store much energy before crack initiation and the magnitude of reflected wave from finite boundaries. However there is no theoretical and experimental elastic-plastic dynamic curving study. This paper proposes a specimen geometryfor a study of dynamic elastic-plastic crack curving and presents a preliminary result. The specimen has a blunt physical crack tip on a side, and a round notch tip on the other side. From the experiment using this specimen, it is found that the narrow plastic zone ahead of the round notch tip produces the change of load direction and anti-symmetricity of the dynamic isochromatics, and each result causes the crack curving phenomenon. After a certain time, as the elastic-plastic crack gets close to the round notch tip near, the degree of the crack curving get larger. The elastic reack curving propagates more sensitively to the surround of crack tip than the plastic crack curving does. The cynamic elastic-plastic crack curving is found to be proportional to the CTOA(the crack tip opening angle). The dynamic elastic-plastic crack may propagate in the direction perpendicular to the loading. An apparant strip yield zone which is similar to the Dugdale strip yield zone is noted ahead of the physical crack tip.

  • PDF

Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior

  • Vatansever, Cuneyt;Kutsal, Kutay
    • Steel and Composite Structures
    • /
    • 제28권6호
    • /
    • pp.767-778
    • /
    • 2018
  • The purpose of this study is to investigate how a fully restrained bolted beam splice affects the connection behavior as a column-tree connection in steel special moment frames under cyclic loading when located within the plastic hinge zone. The impacts of this attachment in protected zone are observed by using nonlinear finite element analyses. This type of splice connection is designed as slip-critical connection and thereby, the possible effects of slippage of the bolts due to a possible loss of pretension in the bolts are also investigated. The 3D models with solid elements that have been developed includes three types of connections which are the connection having fully restrained beam splice located in the plastic hinge location, the connection having fully restrained beam splice located out of the plastic hinge and the connection without beam splice. All connection models satisfied the requirement for the special moment frame connections providing sufficient flexural resistance, determined at column face stated in AISC 341-16. In the connection model having fully restrained beam splice located in the plastic hinge, due to the pretension loss in the bolts, the friction force on the contact surfaces is exceeded, resulting in a relative slip. The reduction in the energy dissipation capacity of the connection is observed to be insignificant. The possibility of the crack occurrence around the bolt holes closest to the column face is found to be higher for the splice connection within the protected zone.

A simple calculation for the preoperative estimation of transverse rectus abdominis myocutaneous free flap volume in 2-stage breast reconstruction using a tissue expander

  • Kono, Hikaru;Ishii, Naohiro;Takayama, Masayoshi;Takemaru, Masashi;Kishi, Kazuo
    • Archives of Plastic Surgery
    • /
    • 제45권4호
    • /
    • pp.333-339
    • /
    • 2018
  • Background Flap volume is an important factor for obtaining satisfactory symmetry in breast reconstruction with a transverse rectus abdominis myocutaneous (TRAM) free flap. We aimed to develop an easy and simple method to estimate flap volume. Methods We performed a preoperative estimation of the TRAM flap volume in five patients with breast cancer who underwent 2-stage breast reconstruction following an immediate tissue expander operation after a simple mastectomy. We measured the height and width of each flap zone using a ruler and measured the tissue thickness by ultrasound. The volume of each zone, approximated as a triangular or square prism, was then calculated. The zone volumes were summed to obtain the total calculated volume of the TRAM flap. We then determined the width of zone II, so that the calculated flap volume was equal to the required flap volume ($1.2{\times}1.05{\times}$the weight of the resected mastectomy tissue). The TRAM flap was transferred vertically so that zone III was located on the upper side, and zone II was trimmed in the sitting position after vascular anastomosis. We compared the estimated flap width of zone II (=X) with the actual flap width of zone II. Results X was similar to the actual measured width. Accurate volume replacement with the TRAM flap resulted in good symmetry in all cases. Conclusions The volume of a free TRAM flap can be straightforwardly estimated preoperatively using the method presented here, with ultrasound, ruler, and simple calculations, and this technique may help reduced the time required for precise flap tailoring.

Short-Term Strength Deficit Following Zone 1 Replantations

  • Roh, Si Young;Shim, Woo Cheol;Lee, Kyung Jin;Lee, Dong Chul;Kim, Jin Soo;Yang, Jae-Won
    • Archives of Plastic Surgery
    • /
    • 제42권5호
    • /
    • pp.614-618
    • /
    • 2015
  • Background Hand strength deficit following digital replantation is usually attributed to the mechanical deficiency of the replanted digit. Zone 1 replantation, however, should not be associated with any mechanical deficit, as the joint and tendon are intact. We evaluate shortterm motor functions in patients who have undergone single-digit zone 1 replantation. Methods A single-institution retrospective review was performed for all patients who underwent zone 1 replantation. Hand and pinch strengths were evaluated using standard dynamometers. Each set of measurements was pooled according to follow-up periods (within 1 month, 1 to 2 months, 2 to 3 months, and after 3 months). The uninjured hand was used as reference for measurements. Results The review identified 53 patients who had undergone zone 1 replantation and presented for follow-up visits. Compared to the uninjured hand, dynamometer measurements revealed significantly less strength for the hand with replanted digit at one month. The relative mean grip, pulp, and key pinch strength were 31%, 46%, and 48% of the uninjured hand. These three strength measurements gradually increased, with relative strength measurements of 59%, 70%, and 78% for 4-month follow up. Conclusions Despite the lack of joint or tendon injury, strength of the injured hand was significantly lower than that of the uninjured hand during the 4 months following replantation. Improved rehabilitation strategies are needed to diminish the short-term negative impact that an isolated zone 1 replantation has on the overall hand strength.

Microstructural characteristics in tough pitch copper for revealing the work hardening region

  • Okayasu, Mitsuhiro;Taki, Tatsuya;Takasu, Satoshi;Takeuchi, Shuhei;Shiraishi, Tetsuro
    • Advances in materials Research
    • /
    • 제1권4호
    • /
    • pp.349-359
    • /
    • 2012
  • To reveal localized plastic deformation zones in a tough pitch copper, the etching characteristics of a copper sample have been examined. The etching was carried out on a sample surface using an etchant consisting of 25 ml nitric acid solution and 75 ml water. To clarify the plastic deformation zone, the sample deformed plastically was heated to between $250^{\circ}C$ and $300^{\circ}C$ before the etching process. This is due to a change of the microstructure and crystal orientation in the plastic deformation zone producing recrystallized small grains. In this case, the plastically deformed zone is severely etched, whereas the undeformed zone is only slightly etched. Identification of the details of the deformation zone from the etching is further discussed.

연성 금속의 파괴과정에서 발생하는 소성영역의 현장 측정 (In-situ Measurement of Plastic Zone Developed During Ductile Fracture Process)

  • 백정현;김도형;강기주
    • 대한기계학회논문집A
    • /
    • 제30권6호
    • /
    • pp.637-642
    • /
    • 2006
  • A plastic zone size is regarded as a measure of material resistance, and also it determines the fracture behavior. The importance of estimating or measuring the plastic zone size cannot be too emphasized. In this article, SDSP(Stereo Digital Speckle Photography) is examined as a new techniques to measure the plastic zone developed in a ductile metal. This technique is simple, vibration free and non-contact, and measures simultaneously in-plane displacements as well as out-of plane displacements like the side necking. Experimental results for a CT specimen are presented to demonstrate the accuracy in comparison with those obtained by recrystallization technique and finite element analysis.

되풀이 소성영역 크기를 이용한 피로 균열 닫힘 거동의 유한요소해석 (Finite Element Analysis for Fatigue Crack Closure Behavior Using Reversed Plastic Zone Size)

  • 최현창
    • 대한기계학회논문집A
    • /
    • 제27권10호
    • /
    • pp.1703-1711
    • /
    • 2003
  • An elastic-plastic finite element analysis is performed to investigate detailed closure behaviour of fatigue cracks in residual stress fields and the numerical results are compared with experimental results. The finite element analysis performed under plane stress using contact elements can predict fatigue crack closure behaviour. The mesh of constant element size along crack surface can not predict the opening level of fatigue crack. Specially, the mesh of element sizes depending upon the reversed plastic zone size included the effect of crack opening point can precisely predict the opening level. By using the concept of the mesh of element sizes depending upon the reversed plastic zone size included the effect of crack opening point, the opening level of fatigue crack can be determined very well.