• Title/Summary/Keyword: PL characteristics

Search Result 487, Processing Time 0.034 seconds

Detecting types for the influence of math teaching methods perceived by high school students on math self-efficacy: Using REBUS-PLS (고등학생이 지각한 수학 수업방식이 수학자기효능감에 미치는 영향력에 대한 유형탐색: REBUS-PLS를 적용하여)

  • Song, Hyo Seob;Jung, Hee Sun
    • The Mathematical Education
    • /
    • v.61 no.4
    • /
    • pp.613-629
    • /
    • 2022
  • This study explored the heterogeneous latent group on the influence of the learner's perceived math teaching method(instructor-centered, learner-centered) on math self-efficacy. In order to profile the characteristics of the detected latent group, the distribution of variables was confirmed, and multi-group analysis was conducted by SEM. According to the analysis results, two latent groups were detected, and the instructor-type group and the learner-type group were named. As a result of post-hoc analysis, the perception of instructor-centered classes and learner-centered classes, and the perception of math teaching ability were similar between the instructor-type and the learner-type group. But the instructor-type group had higher math self-efficacy, math interest, and math class engagement than the learner-type group. Also, in the instructor-type group, the effect of perception of math teaching ability on math self-efficacy and math class engagement was greater than that of the learner-type group. Whereas, in the learner-type group, the effect of math interest on math self-efficacy and math class engagement was greater than that of the instructor-type group. This study presented a new research method on the influence of math teaching methods on learners by applying the REBUS-PLS method.

A Study on Improvement Measures to Strengthen the Police's Ability to Respond to CBRN Terrorism at the Scene (경찰의 화생방테러 현장대응역량 강화를 위한 개선방안 연구)

  • Lee, Deok-Jae;Song, Chang Geun
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.5
    • /
    • pp.116-125
    • /
    • 2022
  • Recent aspects of terrorism varies in various ways according to means, targets, and regions. In particular, the 9/11 terrorist attacks in the United States in 2001 changed the paradigm of each country's terrorism, and the South Korea also participated in the enactment and enforcement of the Anti-Terrorism Act in 2016. Based on this, CBRN terrorism is included in general terrorism, and the National Police Agency plays the role of a control tower, and a system supported by related organizations such as the Ministry of Environment is being built and operated. However, restrictions were confirmed in the organizational system, manpower composition, and equipment and materials in operation in preparation for CBRN within the police. Based on the identified limitations, we proposed improvement plans to strengthen the capacity for CBRN terrorism: establishing a dedicated CBRN organization; creating research organization; and securing additional dedicated personnel. Based on this, as an improvement plan to strengthen the capability of CBRN, the establishment of an organization dedicated to CBRN and a research organization within the National Police Agency, and expansion of electronic equipment suitable for the characteristics of CBRN were proposed. It is expected that the police's on-site response capability system for CBRN terrorism will be strengthened via the proposed improvement measures to recover the various restrictions on the response to CBRN terrorism.

Ecological Characteristic of Warm Temperate Vegetation Distributed around Hakdong and Haegeumgang at Geojae Island (거제도 학동 및 해금강 일대에 분포하는 난대림 식생의 생태적 특성 연구)

  • Lee, Soo-Dong
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.1
    • /
    • pp.72-86
    • /
    • 2022
  • This study was conducted to identify structural characteristics of the evergreen broad-leaved forests distributed in Hak-dong, Geojae island. For a survey, 52 sites were set up in areas with changes in the vegetation community or location environment where Cinnamomum yabunikkei, Neolitsea sericea, and Machilus thunbergii dominated or appeared in the canopy, sub-canopy, or shrub layer. The community classification with TWINSPAN identified the following communities: N. sericea-C. yabunikkei, C. yabunikkei-Camellia japonica, Ca. japonica, Quercus variabilis-Ca. japonica, Pinus thunbergii-Ca. japonica, Castanopsis sieboldii, P. thunbergii, and Platycarya strobilacea-Mallotus japonicus. Considering the result of the study that succession series of warm-temperate forest reflecting the latent natural vegetation is the transition of conifers and deciduous broad-leaved forest to evergreen broad-leaved forest, the communities predominated by the communities predominated by the communities predominated by P. thunbergii, Q. variabilis, and Pl. strobilacea are likely to transform into the evergreen forest predominated by N. sericea and C. yabunikkei. The sites where C. yabunikkei, N. sericea, and Castanopsis sieboldii are dominant in the canopy and sub-canopy layers are likely to maintain the status quo if there is no artificial disturbance. The relationship between the impact of the environmental factors and the vegetation distribution showed silt among the physical properties of the soil directly or indirectly affected it, which was judged to be due to the fact that it was located on a steep slope. The soil acidity (pH) was 5-5.84, electrical conductivity 0.047-0.139 dS/m, and organic matter content was 3.32-12.06%. Although there were differences by the colony, they were generally low.

Development of novel oxyfluoride glasses and glass ceramics for photoluminescence material by a containerless processing (무용기 용융법을 활용한 형광소재용 결정화 유리 개발)

  • Hyerin Jo;Minsung Hwang;Youngjin Lee;Jaeyeop Chung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.33 no.5
    • /
    • pp.181-186
    • /
    • 2023
  • In this study, novel Eu2O3-BaF2-La2O3-B2O3 oxyfluoride glasses and glass ceramics were developed by a containerless processing. Differential thermal analysis (DTA) analysis was performed to analyze the thermophysical properties of oxyfluoride glasses doped with Eu2O3, and photoluminescence (PL) characteristics were analyzed to evaluate the luminous efficiency depending on the degree of crystallinity. The glass transition temperature decreased with increasing BaF2 concentration since BaF2 acts as a network modifier in this glass system. In addition, thermal stability which can be estimated by the difference between the glass transition temperature and the onset temperature of the crystallization decreased with increasing BaF2 contents. The peak related to the BaF2 crystal was confirmed after the crystallization by X-ray Diffraction (XRD) analysis. Photoluminescence intensity increased after the crystallization which indicates that the Eu3+ ions are sited in BaF2 crystal. La 3d5/2 x-ray photoelectron spectroscopy (XPS) and F1s XPS spectra were analyzed to precisely understand the behavior of the fluorine ion in the glass structure. Fluorine tends to bond with the network modifying cations such as La3+ and Ba2+ ions and after the crystallization the La-F bonds decreased because F- ions used to form BaF2 crystals.

An Experimental Study on Friction Welding and Heat Treatment of Engine Exhaust Valve Steels ( SCr4-21-4 N , SUH3-21-4-N (기관배기 밸브용 강 ( SCr4-21-4N , SUH3-21-4N ) 의 마찰압접과 열처리에 관한 실험적 연구)

  • 오세규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.79-87
    • /
    • 1978
  • This is an experimental study on friction welding and heat treatment of engine exhaust valve materials whose welding combination is SCr4 as stem to 21-4N as head and SUH3 to 21-4N. In this study, not only the experiments of friction welding under the selected optimum welding condition and the examination of the mechanical properties were carried out, but also the heat treatment of friction welded specimens under the two selected conditions was taken to obtain the better welding character, eliminating the latent stress and the hardness peak which appeared at the welded zones of heat resisting steel(21-4N, SUH3) and low alloyed steel ($SCr_4$) friction weldments. The results obtained by the experiments and consideration in this study are as follows: I) It was experimentally proved quite reasonable that 'speed=3,OOO rpm, heating pressure Pl=8 kg/ mm2, upsetting pressure p, = 20 kg/mm', heating time $t_1$ = 3 see, upsetting time TEX>$t_2$ = 2.5 sec' was selected as the optimum welding condition for friction-welding the engine exhaust valve materials $SCr_4$ to 21-4 Nand SUH 3 to 21-4 N. 2) The results of the previous study and this one on friction welding of such dissimilar materials as SUH 3-SUH 31, SCr 4-SUH 31, SCr 4-SUH 3, SUH 3-CRK 22, SCr4-21-4 Nand SUH3-21-4 N agreed with each other substantially in the friction welding characteristics at welded interface zones. 3) It was also certified quite satisfactory that '600\ulcornerCX30 min. Xroom air cooling' as an optimum heat treatment condition of the friction welded materials SCr 4-21-4 Nand SUH 3-21-4 N was experimentally determined to eliminate the latent stress and the hardness peak at welded zones. 4) About 20% of the tensile strength before heat treatment of friction welded specimens was decreased after heat treatment 600\ulcornerCX30 min. Xair cooling, but the location of fracture was moved from heat affected zone to parent $SCr_4$ & SUH3. 5) Microscopic examination of the weld joints friction-welded and heat-treated under the above mentioned conditions revealed that the weld zone is very narrow and has a fine grained intermixed structure without any welding defects. 6) The above mentioned conditions can be also utilized as friction welding parameters of the other dissimiar materials for engine valve production.

  • PDF

The Antimicrobial Characteristics of McSSP-31 Purified from the Hemocyte of the Hard-shelled Mussel, Mytilus coruscus (참담치(Mytilus coruscus) 혈구(hemocyte)에서 분리한 McSSP-31의 항균 특성 분석)

  • Oh, Ryunkyoung;Lee, Min Jeong;Kim, Young-Ok;Nam, Bo-Hye;Kong, Hee Jeong;Kim, Joo-Won;Park, Jung-Youn;Seo, Jung-Kil;Kim, Dong-Gyun
    • Journal of Life Science
    • /
    • v.27 no.11
    • /
    • pp.1276-1289
    • /
    • 2017
  • This study isolated and purified the antimicrobial peptide McSSP-31 from an acidified hemocyte extract of a Mytilus coruscus. The antimicrobial peptide was purified by using a $C_{18}$ reversed-phase high-performance liquid chromatography (HPLC). The peptide was determined to be 3330.549 Da by matrix assisted-laser desorption ionization time-of-flight mass spectrophotometer (MALDI-TOF/MS). The N-terminus of a 14 amino-acid sequence was identified as P-S-P-T-R-R-S-T-S-R-S-K-S-R by Edman degradation method. The acquired sequence showed a 93% similarity with the sperm-specific protein Phi-1, which is from M. californianus. The identified open-reading frame (ORF) of peptide was 306 bp encoding 101 amino acids, which was analyzed by rapid amplification of cDNA ends (RACE), cloning and sequencing analysis. We compared the full sequence with other known proteins that reveal the sperm-specific protein Phi-1 (93.5%) of M. californianus. Synthesized antimicrobial peptide (McSSP-31) showed antibacterial activity against gram-positive bacteria including B. subtilis, S. mutans, S. aureus and gram-negative bacteria including E. coli, K. pneumoniae, P. mirabilis, P. aeruginosa and fungi, C. albicans. Also, synthesized peptide showed strong antibacterial activity against antibiotic-resistant strains, including S. aureus. The cytotoxicity of the peptide was determined by using the HUVEC human cell line. The peptide did not exhibit any significant cytotoxic effects on the normal human cell line, and it had very low hemolytic activity with flounder hemoglobin. The results demonstrated that peptide purified from the hemocyte of a M. coruscus exhibits antibacterial activity against various bacteria and has the potential to be an alternative antibiotic agent.

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.